OS command injection in Schneider Electric PowerLogic™ P7
Key facts
- Attack vector
- Network
- Privileges required
- High
- User interaction
- None
- Attack complexity
- Low
- Attack requirements
- None
- Impact type
- Code execution
- Confidentiality · integrity · availability
- High · High · High
- Fix status
- No fix listed
Attack profile from CVSS 4.0 · CNA. Fix status from CNA. Impact type from CWE-78.
Summary
CWE-78 Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability exists that could allow unauthorized execution of commands with elevated privileges, impacting system integrity, confidentiality, and availability when a privileged authenticated user interacts with a vulnerable network-exposed service.
Why it matters now
SSVC decision points
CISA ADP · SSVC 2.0.3
- Exploitation
- None
- Automatable
- No
- Technical impact
- Total
The decision (Track, Attend, Act) also depends on your mission and well-being impact; see CISA's SSVC guide.
Affected products
| Vendor | Product | Affected versions | Fixed in | Status | Source |
|---|---|---|---|---|---|
| Schneider Electric | PowerLogic™ P7 | up to V02.003.001.000 | — | No fix listed | CNA |
- PowerLogic™ P7 VendorSchneider Electric Affected up to V02.003.001.000 Fixed in — No fix listed CNA
CPE configurations NVD · 2
| CPE | Versions | Role | Vendor |
|---|---|---|---|
| cpe:2.3:o:schneider-electric:powerlogic_p7_firmware:*:*:*:*:*:*:*:* | before 02.004.001.000 | Vulnerable | Schneider Electric |
| cpe:2.3:h:schneider-electric:powerlogic_p7:-:*:*:*:*:*:*:* | not specified by NVD | Running on | Schneider Electric |
- cpe:2.3:o:schneider-electric:powerlogic_p7_firmware:*:*:*:*:*:*:*:* Versions before 02.004.001.000 Vulnerable ·Schneider Electric
- cpe:2.3:h:schneider-electric:powerlogic_p7:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Schneider Electric
Remediation
No fixed version listed by the sources yet.
Timeline
- 2026-10-02 Threatist record created from CVE-2026-9717
- 2026-10-03 Alias added: GHSA-47f2-rprg-7x63
References
More Schneider Electric Powerlogic P7 Firmware vulnerabilities
- TI-2026-08514 NULL pointer dereference in Schneider Electric PowerLogic™ P7 CVSS 4.0HIGH 8.7
- TI-2026-08516 Reachable assertion in Schneider Electric PowerLogic™ P7 CVSS 4.0MEDIUM 6.9
Sources
- CVE-2026-9717 · CVE Program
- CVE-2026-9717 · NVD
- FIRST EPSS
- GHSA-47f2-rprg-7x63 · GitHub Advisory Database · CC BY 4.0
This product uses the NVD API but is not endorsed or certified by the NVD. Sources and licences