Read the docs
TI-2026-10774 Aliases CVE-2026-12562GHSA-w374-9vqx-5hr2

Toptech Systems RCU II+ and Multiload II+ Missing Authentication for Critical Function

Priority MEDIUM 40CWE-306Published · Updated

Key facts

Attack vector
Adjacent network
Privileges required
None
User interaction
None
Attack complexity
Low
Attack requirements
None
Impact type
Security bypass
Confidentiality · integrity · availability
High · High · High
Fix status
Fixed

Attack profile from CVSS 4.0 · CNA. Fix status from CNA. Impact type from CWE-306.

Summary

The RCU II+ and Multiload II+ are vulnerable to an unauthenticated service that exposes a debug interface granting full root-level access to the embedded system. This vulnerability stems from a network-accessible port running a Target Communications Framework (TCF) service that does not require any authentication, allowing an attacker to directly interact with the Linux environment that powers the device. Once connected, an attacker can freely view and modify the filesystem, manipulate running processes, and control network interfaces, enabling deep alteration of system behavior.

Why it matters now

Exploitation None reported CISA SSVC · not in CISA KEV
EPSS 0.00458 39th percentileScored 2026-11-07
Fix Fixed RCU II+ (Toptech Systems): 2025-11-24Multiload II+ (Toptech Systems): 2025-11-24

SSVC decision points

CISA ADP · SSVC 2.0.3

Exploitation
None
Automatable
No
Technical impact
Total

The decision (Track, Attend, Act) also depends on your mission and well-being impact; see CISA's SSVC guide.

Affected products

VendorProductAffected versionsFixed inStatusSource
Toptech SystemsRCU II+before 2025-11-242025-11-24Patch availableCNA
Toptech SystemsMultiload II+before 2025-11-242025-11-24Patch availableCNA
  • RCU II+ VendorToptech Systems Affected before 2025-11-24 Fixed in 2025-11-24 Patch available CNA
  • Multiload II+ VendorToptech Systems Affected before 2025-11-24 Fixed in 2025-11-24 Patch available CNA

Remediation

  • Fix · CNA RCU II+ (Toptech Systems) Fixed in 2025-11-24
  • Fix · CNA Multiload II+ (Toptech Systems) Fixed in 2025-11-24

Timeline

  1. 2026-10-02 Threatist record created from CVE-2026-12562
  2. 2026-10-03 Alias added: GHSA-w374-9vqx-5hr2

References

  • TI-2026-50020 Toptech TMS7 and TopHAT Files or Directories Accessible to External Parties CVSS 4.0CRITICAL 10.0
  • TI-2026-49169 Toptech TMS7 and TopHAT Unrestricted Upload of File with Dangerous Type CVSS 4.0CRITICAL 9.4
  • TI-2026-50785 Toptech TMS7 and TopHAT SQL Injection CVSS 4.0HIGH 8.5
  • TI-2026-50783 Toptech TMS7 and TopHAT SQL Injection CVSS 4.0HIGH 8.5
  • TI-2026-48473 Toptech TMS7 and TopHAT SQL Injection CVSS 4.0HIGH 8.5
  • TI-2026-47852 Toptech TMS7 and TopHAT SQL Injection CVSS 4.0HIGH 8.5
See all 10 →

Sources