Read the docs
TI-2026-27269 Aliases CVE-2026-35068GHSA-q7j8-gmpq-hc8j

SQL injection in Dell PowerFlex

Priority LOW 25CWE-89Published · Updated

Key facts

Attack vector
Adjacent network
Privileges required
Low
User interaction
None
Attack complexity
Low
Impact type
SQL injection
Confidentiality · integrity · availability
High · None · None
Fix status
Fixed

Attack profile from CVSS 3.1 · NVD. Fix status from CNA. Impact type from CWE-89.

Summary

Dell PowerFlex Manager, version(s) prior to 5.1.0.1, contain(s) an Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection') vulnerability. A low privileged attacker with adjacent network access could potentially exploit this vulnerability, leading to information disclosure.

Why it matters now

Exploitation None reported CISA SSVC · not in CISA KEV
EPSS 0.00192 8th percentileScored 2026-11-07
Fix Fixed PowerFlex (Dell): 5.1.0.1 or later, 4.5.5.2 or later

SSVC decision points

CISA ADP · SSVC 2.0.3

Exploitation
None
Automatable
No
Technical impact
Partial

The decision (Track, Attend, Act) also depends on your mission and well-being impact; see CISA's SSVC guide.

Affected products

VendorProductAffected versionsFixed inStatusSource
DellPowerFlexbefore 5.1.0.1 or later; before 4.5.5.2 or later5.1.0.1 or later, 4.5.5.2 or laterPatch availableCNA
  • PowerFlex VendorDell Affected before 5.1.0.1 or later; before 4.5.5.2 or later Fixed in 5.1.0.1 or later, 4.5.5.2 or later Patch available CNA

CPE configurations NVD · 1

CPEVersionsRoleVendor
cpe:2.3:a:dell:powerflex_manager:*:*:*:*:*:*:*:*before 4.5.5.2; 4.6.0 to before 5.1.0.1VulnerableDell
  • cpe:2.3:a:dell:powerflex_manager:*:*:*:*:*:*:*:* Versions before 4.5.5.2; 4.6.0 to before 5.1.0.1 Vulnerable ·Dell

Remediation

  • Fix · CNA PowerFlex (Dell) Fixed in 5.1.0.1 or later, 4.5.5.2 or later

Fixed in the same release

Records fixed by the same vendor advisory or release, as the CNA lists them.

  • Advisory ·

    Dell PowerFlex — dell.com/support/kbdoc/en-us/000477538/dsa-2026-066-securit…

    10 records Highest priority Priority MEDIUM 1 MEDIUM, 9 LOW

    Other records, highest priority first

    • TI-2026-27266 Missing authentication in Dell PowerFlexPriority MEDIUM 40
    • TI-2026-36652 Improper authentication in Dell PowerFlexPriority LOW 35
    • TI-2026-25274 Improper authentication in Dell PowerFlexPriority LOW 35

Timeline

  1. 2026-10-02 Threatist record created from CVE-2026-35068
  2. 2026-10-03 Alias added: GHSA-q7j8-gmpq-hc8j

References

  • TI-2024-24670 Link following in Dell PowerFlex appliance CVSS 3.1CRITICAL 10.0
  • TI-2026-40869 OS command injection in Dell PowerFlex Manager CVSS 3.1CRITICAL 9.1
  • TI-2026-27266 Missing authentication in Dell PowerFlex CVSS 3.1HIGH 8.8
  • TI-2025-23805 Dell PowerFlex Manager, version(s) <=4.6.2, contain(s) an Exposure of Information Through… CVSS 3.1HIGH 7.5
  • TI-2026-40871 SQL injection in Dell PowerFlex Manager CVSS 3.1HIGH 8.5
  • TI-2024-24671 Insecure storage of sensitive information in Dell PowerFlex appliance CVSS 3.1HIGH 8.2
See all 24 →