SQL injection in Siemens blueplanet 100 NX3 M8
Key facts
- Attack vector
- Adjacent network
- Privileges required
- High
- User interaction
- None
- Attack complexity
- High
- Attack requirements
- None
- Impact type
- SQL injection
- Confidentiality · integrity · availability
- Low · High · High
- Fix status
- Fixed
Attack profile from CVSS 4.0 · CNA. Fix status from CNA. Impact type from CWE-89.
Summary
A vulnerability has been identified in blueplanet 100 NX3 M8 (All versions), blueplanet 100 TL3 GEN2 (All versions), blueplanet 105 TL3 (All versions < V3.92), blueplanet 105 TL3 GEN2 (All versions), blueplanet 110 TL3 (All versions < V3.92), blueplanet 125 NX3 M10 (All versions), blueplanet 125 TL3 (All versions < V3.92), blueplanet 125 TL3 GEN2 (All versions), blueplanet 137 TL3 (All versions < V3.92), blueplanet 150 TL3 (All versions < V3.92), blueplanet 150 TL3 GEN2 (All versions), blueplanet 155 TL3 (All versions < V3.92), blueplanet 155 TL3 GEN2 (All versions), blueplanet 165 TL3 (All versions < V3.92), blueplanet 165 TL3 GEN2 (All versions), blueplanet 87.0 TL3 (All versions < V3.92), blueplanet 87.0 TL3 GEN2 (All versions), blueplanet 92.0 TL3 (All versions < V3.92), blueplanet 92.0 TL3 GEN2 (All versions), blueplanet gridsave 110 TL3-S (All versions < V3.92), blueplanet gridsave 137 TL3-S (All versions < V3.92), blueplanet gridsave 92.0 TL3-S (All versions < V3.92). Improper neutralization of special elements used in an sql command ('sql injection') in KACO Meteor server allows an authorized attacker to elevate privileges over a local network.
Why it matters now
SSVC decision points
CISA ADP · SSVC 2.0.3
- Exploitation
- None
- Automatable
- No
- Technical impact
- Total
The decision (Track, Attend, Act) also depends on your mission and well-being impact; see CISA's SSVC guide.
Affected products
| Vendor | Product | Affected versions | Fixed in | Status | Source |
|---|---|---|---|---|---|
| Siemens | blueplanet 100 NX3 M8 | all versions | — | No fix listed | CNA |
| Siemens | blueplanet 100 TL3 GEN2 | all versions | — | No fix listed | CNA |
| Siemens | blueplanet 105 TL3 | before V3.92 | V3.92 | Patch available | CNA |
| Siemens | blueplanet 105 TL3 GEN2 | all versions | — | No fix listed | CNA |
| Siemens | blueplanet 110 TL3 | before V3.92 | V3.92 | Patch available | CNA |
| Siemens | blueplanet 125 NX3 M10 | all versions | — | No fix listed | CNA |
| Siemens | blueplanet 125 TL3 | before V3.92 | V3.92 | Patch available | CNA |
| Siemens | blueplanet 125 TL3 GEN2 | all versions | — | No fix listed | CNA |
| Siemens | blueplanet 137 TL3 | before V3.92 | V3.92 | Patch available | CNA |
| Siemens | blueplanet 150 TL3 | before V3.92 | V3.92 | Patch available | CNA |
| Siemens | blueplanet 150 TL3 GEN2 | all versions | — | No fix listed | CNA |
| Siemens | blueplanet 155 TL3 | before V3.92 | V3.92 | Patch available | CNA |
| Siemens | blueplanet 155 TL3 GEN2 | all versions | — | No fix listed | CNA |
| Siemens | blueplanet 165 TL3 | before V3.92 | V3.92 | Patch available | CNA |
| Siemens | blueplanet 165 TL3 GEN2 | all versions | — | No fix listed | CNA |
| Siemens | blueplanet 87.0 TL3 | before V3.92 | V3.92 | Patch available | CNA |
| Siemens | blueplanet 87.0 TL3 GEN2 | all versions | — | No fix listed | CNA |
| Siemens | blueplanet 92.0 TL3 | before V3.92 | V3.92 | Patch available | CNA |
| Siemens | blueplanet 92.0 TL3 GEN2 | all versions | — | No fix listed | CNA |
| Siemens | blueplanet gridsave 110 TL3-S | before V3.92 | V3.92 | Patch available | CNA |
| Siemens | blueplanet gridsave 137 TL3-S | before V3.92 | V3.92 | Patch available | CNA |
| Siemens | blueplanet gridsave 92.0 TL3-S | before V3.92 | V3.92 | Patch available | CNA |
- blueplanet 100 NX3 M8 VendorSiemens Affected all versions Fixed in — No fix listed CNA
- blueplanet 100 TL3 GEN2 VendorSiemens Affected all versions Fixed in — No fix listed CNA
- blueplanet 105 TL3 VendorSiemens Affected before V3.92 Fixed in V3.92 Patch available CNA
- blueplanet 105 TL3 GEN2 VendorSiemens Affected all versions Fixed in — No fix listed CNA
- blueplanet 110 TL3 VendorSiemens Affected before V3.92 Fixed in V3.92 Patch available CNA
- blueplanet 125 NX3 M10 VendorSiemens Affected all versions Fixed in — No fix listed CNA
- blueplanet 125 TL3 VendorSiemens Affected before V3.92 Fixed in V3.92 Patch available CNA
- blueplanet 125 TL3 GEN2 VendorSiemens Affected all versions Fixed in — No fix listed CNA
- blueplanet 137 TL3 VendorSiemens Affected before V3.92 Fixed in V3.92 Patch available CNA
- blueplanet 150 TL3 VendorSiemens Affected before V3.92 Fixed in V3.92 Patch available CNA
- blueplanet 150 TL3 GEN2 VendorSiemens Affected all versions Fixed in — No fix listed CNA
- blueplanet 155 TL3 VendorSiemens Affected before V3.92 Fixed in V3.92 Patch available CNA
- blueplanet 155 TL3 GEN2 VendorSiemens Affected all versions Fixed in — No fix listed CNA
- blueplanet 165 TL3 VendorSiemens Affected before V3.92 Fixed in V3.92 Patch available CNA
- blueplanet 165 TL3 GEN2 VendorSiemens Affected all versions Fixed in — No fix listed CNA
- blueplanet 87.0 TL3 VendorSiemens Affected before V3.92 Fixed in V3.92 Patch available CNA
- blueplanet 87.0 TL3 GEN2 VendorSiemens Affected all versions Fixed in — No fix listed CNA
- blueplanet 92.0 TL3 VendorSiemens Affected before V3.92 Fixed in V3.92 Patch available CNA
- blueplanet 92.0 TL3 GEN2 VendorSiemens Affected all versions Fixed in — No fix listed CNA
- blueplanet gridsave 110 TL3-S VendorSiemens Affected before V3.92 Fixed in V3.92 Patch available CNA
- blueplanet gridsave 137 TL3-S VendorSiemens Affected before V3.92 Fixed in V3.92 Patch available CNA
- blueplanet gridsave 92.0 TL3-S VendorSiemens Affected before V3.92 Fixed in V3.92 Patch available CNA
Remediation
- Fix · CNA blueplanet 105 TL3 (Siemens) Fixed in V3.92
- Fix · CNA blueplanet 110 TL3 (Siemens) Fixed in V3.92
- Fix · CNA blueplanet 125 TL3 (Siemens) Fixed in V3.92
- Fix · CNA blueplanet 137 TL3 (Siemens) Fixed in V3.92
- Fix · CNA blueplanet 150 TL3 (Siemens) Fixed in V3.92
- Fix · CNA blueplanet 155 TL3 (Siemens) Fixed in V3.92
- Fix · CNA blueplanet 165 TL3 (Siemens) Fixed in V3.92
- Fix · CNA blueplanet 87.0 TL3 (Siemens) Fixed in V3.92
- Fix · CNA blueplanet 92.0 TL3 (Siemens) Fixed in V3.92
- Fix · CNA blueplanet gridsave 110 TL3-S (Siemens) Fixed in V3.92
- Fix · CNA blueplanet gridsave 137 TL3-S (Siemens) Fixed in V3.92
- Fix · CNA blueplanet gridsave 92.0 TL3-S (Siemens) Fixed in V3.92
Fixed in the same release
Records fixed by the same vendor advisory or release, as the CNA lists them.
- Release ·
Siemens blueplanet 105 TL3, blueplanet 110 TL3 and 7 more products V3.92
2 records Highest priority Priority LOW 2 LOW
Other records, highest priority first
- TI-2025-27337 A vulnerability has been identified in blueplanet 100 NX3 M8 (All versions), blueplanet…Priority LOW 33
Timeline
- 2026-10-02 Threatist record created from CVE-2026-41125
- 2026-10-03 Alias added: GHSA-whgx-jm4q-gfmv
- 2026-10-13 Title updated · CNA
- 2026-10-13 Fix available: Siemens/blueplanet 105 [email protected], Siemens/blueplanet 110 [email protected], Siemens/blueplanet 125 [email protected] +9 · CNA
References
More Siemens vulnerabilities
- TI-2026-20057 Authentication bypass in Fortinet FortiWeb KEVCVSS 3.1CRITICAL 9.4
- TI-2025-26358 tls: fix handling of zero-length records on the rx_list KEVCVSS 3.1CRITICAL 9.8
- TI-2025-18911 Heap-based buffer overflow in Fortinet FortiSwitchManager KEVCVSS 3.1CRITICAL 9.8
- TI-2025-09686 Type confusion in Google Chrome KEVCVSS 3.1CRITICAL 9.8
- TI-2022-07142 Code injection in Spring Framework KEVCVSS 3.1CRITICAL 9.8
- TI-2021-19919 Apache Log4j2 JNDI features do not protect against attacker controlled LDAP and other JNDI related endpoints KEVCVSS 3.1CRITICAL 10.0
Sources
- CVE-2026-41125 · CVE Program
- CVE-2026-41125 · NVD
- FIRST EPSS
- GHSA-whgx-jm4q-gfmv · GitHub Advisory Database · CC BY 4.0
This product uses the NVD API but is not endorsed or certified by the NVD. Sources and licences