Read the docs
TI-2026-31024 Aliases CVE-2026-42806GHSA-wf7g-q2xv-vf8v

Out-of-bounds read in Bosch Sensortec BME690 SensorAPI

Priority LOW 19CWE-125Published · Updated

Key facts

Attack vector
Physical
Privileges required
None
User interaction
None
Attack complexity
Low
Impact type
—
Confidentiality · integrity · availability
Low · Low · Low
Fix status
No fix listed

Attack profile from CVSS 3.1 · CNA. Fix status from CNA.

Summary

An out-of-bounds read vulnerability was discovered in the Bosch BME690 SensorAPI (C-driver) in version v1.0.3 and prior, specifically within the field data parsing logic in read_all_field_data (bme69x.c). The driver prefetches heater configuration registers into a contiguous 30-byte stack buffer (set_val) mapping IDAC, RES_HEAT, and GAS_WAIT tables. When parsing sensor field data, the gas_index is extracted using a 4-bit mask (0..15) but lacks boundary verification against the valid range (0..9). An attacker or a compromised peripheral mimicking a sensor on the I2C/SPI bus could return a payload with a gas index value of 10 or higher. This causes the driver to perform an out-of-bounds array access (set_val[20 + gas_index]), reading up to 6 bytes past the stack buffer. The leaked out-of-bounds byte is then written into the public gas_wait field, which may lead to measurement corruption or leak adjacent stack memory when telemetered or logged.

Why it matters now

Exploitation None reported CISA SSVC · not in CISA KEV
EPSS 0.00205 10th percentileScored 2026-11-07
Fix No fix listed No fixed version in the sources yet

SSVC decision points

CISA ADP · SSVC 2.0.3

Exploitation
None
Automatable
No
Technical impact
Partial

The decision (Track, Attend, Act) also depends on your mission and well-being impact; see CISA's SSVC guide.

Affected products

VendorProductAffected versionsFixed inStatusSource
Bosch SensortecBME690 SensorAPI (C)1.0.1 – 1.0.3—No fix listedCNA
  • BME690 SensorAPI (C) VendorBosch Sensortec Affected 1.0.1 – 1.0.3 Fixed in — No fix listed CNA

Remediation

No fixed version listed by the sources yet.

Timeline

  1. 2026-10-02 Threatist record created from CVE-2026-42806
  2. 2026-10-03 Alias added: GHSA-wf7g-q2xv-vf8v

References

  • TI-2026-31023 Stack-based buffer overflow in Bosch Sensortec BHI385 SensorAPI CVSS 3.1HIGH 8.4
  • TI-2026-31025 Heap-based buffer overflow in Bosch Sensortec COINES_SDK CVSS 3.1HIGH 8.0
  • TI-2026-31022 Stack-based buffer overflow in Bosch Sensortec BHI360_SensorAPI CVSS 3.1HIGH 7.6
  • TI-2026-31026 Buffer overflow in Bosch Sensortec COINES_SDK CVSS 3.1MEDIUM 6.8