Read the docs
TI-2026-36520 Aliases CVE-2026-49343GHSA-fw38-pc54-jvx9

Klever-Go KVM: Throttler slot leak in trie account-data sync causes epoch bootstrap / state sync DoS

Priority MEDIUM 60CWE-400Published · Updated

Key facts

Attack vector
Network
Privileges required
None
User interaction
None
Attack complexity
High
Impact type
Denial of service
Confidentiality · integrity · availability
None · None · High
Fix status
Fixed

Attack profile from CVSS 3.1 · CNA. Fix status from CNA and GitHub. Impact type from CWE-400.

Summary

Klever-Go is the Go implementation of the Klever blockchain protocol. In versions prior to 1.7.18, the account-data trie syncers are vulnerable to a resource-exhaustion flaw that leaks bounded throttler slots on error paths. In syncDataTrie() (in both userAccountsSyncer.go and kappAccountsSyncer.go), StartProcessing() reserves a slot from the NumGoRoutinesThrottler, but the corresponding EndProcessing() is only called on the success path and on the duplicate-root early return. As a result, any error from trie.NewTrie(), trie.NewTrieSyncer(), or trieSyncer.StartSyncing() (including the network-dependent timeout path) permanently consumes one slot for the lifetime of the throttler. An attacker who can repeatedly cause trie-node sync failures or timeouts during bootstrap can exhaust the bounded throttler, after which further account-data trie syncs stop making progress and SyncAccounts() returns a timeout. Because epoch bootstrap in syncUserAccountsState() and syncKappAccountsState() aborts on any such error, this causes bootstrap to fail, a core availability issue affecting fresh, restarting, or resyncing nodes and validators. This issue is fixed in version 1.7.18.

Why it matters now

Exploitation Proof of concept CISA SSVC · not in CISA KEV
EPSS 0.00412 35th percentileScored 2026-11-07
Fix Fixed klever-go (klever-io): 1.7.18github.com/klever-io/klever-go (Go): 1.7.18

SSVC decision points

CISA ADP · SSVC 2.0.3

Exploitation
Poc
Automatable
No
Technical impact
Partial

The decision (Track, Attend, Act) also depends on your mission and well-being impact; see CISA's SSVC guide.

Affected products

VendorProductAffected versionsFixed inStatusSource
klever-ioklever-gobefore 1.7.181.7.18Patch availableCNA
—github.com/klever-io/klever-go (Go)before 1.7.181.7.18Patch availableGHSA-fw38-pc54-jvx9
  • klever-go Vendorklever-io Affected before 1.7.18 Fixed in 1.7.18 Patch available CNA
  • github.com/klever-io/klever-go (Go) Vendor— Affected before 1.7.18 Fixed in 1.7.18 Patch available GHSA-fw38-pc54-jvx9

Remediation

  • Fix · CNA klever-go (klever-io) Fixed in 1.7.18
  • Fix · GHSA-fw38-pc54-jvx9 github.com/klever-io/klever-go (Go) Fixed in 1.7.18 Advisory →

Timeline

  1. 2026-10-02 Threatist record created from CVE-2026-49343
  2. 2026-10-03 Alias added: GHSA-fw38-pc54-jvx9

References

  • TI-2026-40253 Klever-Go: SFT add-quantity `int64` overflow bypasses a finite per-nonce MaxSupply CVSS 4.0HIGH 8.7
  • TI-2026-40252 Klever-Go: Percentage-transfer royalty skips the source debit at exactly-100% splits CVSS 4.0HIGH 8.7
  • TI-2026-58874 Klever-Go: /log controls global node logging CVSS 3.1HIGH 8.6
  • TI-2026-32588 Klever-Go MultiDataInterceptor: remote OOM via crafted compressed P2P payload CVSS 3.1HIGH 8.6
  • TI-2026-39560 Integer underflow in klever-io klever-go CVSS 3.1CRITICAL 9.6
  • TI-2026-58875 Resource allocation without limits in klever-io klever-go CVSS 3.1HIGH 7.5
See all 17 →

Sources