Cross-site scripting in Siemens Teamcenter V2412
Key facts
- Attack vector
- Network
- Privileges required
- None
- User interaction
- Active
- Attack complexity
- Low
- Attack requirements
- None
- Impact type
- Cross-site scripting
- Confidentiality · integrity · availability
- High · High · None
- Fix status
- Fixed
Attack profile from CVSS 4.0 · CNA. Fix status from CNA. Impact type from CWE-79.
Summary
A vulnerability has been identified in Teamcenter V2412 (All versions < V2412.0013), Teamcenter V2506 (All versions < V2506.0010), Teamcenter V2512 (All versions < V2512.2607), Teamcenter V2606 (All versions < V2606.2607). Affected applications do not properly encode user-supplied input reflected into HTML attribute contexts within the authentication redirect flow (/auth/ endpoint). This could allow an unauthenticated remote attacker to inject arbitrary JavaScript into the browser of an authenticated user who loads a crafted URL, enabling the attacker to perform actions within the victim's Teamcenter session.
Why it matters now
SSVC decision points
CISA ADP · SSVC 2.0.3
- Exploitation
- None
- Automatable
- No
- Technical impact
- Partial
The decision (Track, Attend, Act) also depends on your mission and well-being impact; see CISA's SSVC guide.
Affected products
| Vendor | Product | Affected versions | Fixed in | Status | Source |
|---|---|---|---|---|---|
| Siemens | Teamcenter V2412 | before V2412.0013 | V2412.0013 | Patch available | CNA |
| Siemens | Teamcenter V2506 | before V2506.0010 | V2506.0010 | Patch available | CNA |
| Siemens | Teamcenter V2512 | before V2512.2607 | V2512.2607 | Patch available | CNA |
| Siemens | Teamcenter V2606 | before V2606.2607 | V2606.2607 | Patch available | CNA |
- Teamcenter V2412 VendorSiemens Affected before V2412.0013 Fixed in V2412.0013 Patch available CNA
- Teamcenter V2506 VendorSiemens Affected before V2506.0010 Fixed in V2506.0010 Patch available CNA
- Teamcenter V2512 VendorSiemens Affected before V2512.2607 Fixed in V2512.2607 Patch available CNA
- Teamcenter V2606 VendorSiemens Affected before V2606.2607 Fixed in V2606.2607 Patch available CNA
Remediation
- Fix · CNA Teamcenter V2412 (Siemens) Fixed in V2412.0013
- Fix · CNA Teamcenter V2506 (Siemens) Fixed in V2506.0010
- Fix · CNA Teamcenter V2512 (Siemens) Fixed in V2512.2607
- Fix · CNA Teamcenter V2606 (Siemens) Fixed in V2606.2607
Timeline
- 2026-10-02 Threatist record created from CVE-2026-58113
- 2026-10-03 Alias added: GHSA-66wm-wchr-375j
References
More Siemens vulnerabilities
- TI-2026-20057 Authentication bypass in Fortinet FortiWeb KEVCVSS 3.1CRITICAL 9.4
- TI-2025-26358 tls: fix handling of zero-length records on the rx_list KEVCVSS 3.1CRITICAL 9.8
- TI-2025-18911 Heap-based buffer overflow in Fortinet FortiSwitchManager KEVCVSS 3.1CRITICAL 9.8
- TI-2025-09686 Type confusion in Google Chrome KEVCVSS 3.1CRITICAL 9.8
- TI-2022-07142 Code injection in Spring Framework KEVCVSS 3.1CRITICAL 9.8
- TI-2021-19919 Apache Log4j2 JNDI features do not protect against attacker controlled LDAP and other JNDI related endpoints KEVCVSS 3.1CRITICAL 10.0
Sources
- CVE-2026-58113 · CVE Program
- CVE-2026-58113 · NVD
- FIRST EPSS
- GHSA-66wm-wchr-375j · GitHub Advisory Database · CC BY 4.0
This product uses the NVD API but is not endorsed or certified by the NVD. Sources and licences