Read the docs
TI-2026-41853 Aliases CVE-2026-58113GHSA-66wm-wchr-375j

Cross-site scripting in Siemens Teamcenter V2412

Priority LOW 37CWE-79Published · Updated

Key facts

Attack vector
Network
Privileges required
None
User interaction
Active
Attack complexity
Low
Attack requirements
None
Impact type
Cross-site scripting
Confidentiality · integrity · availability
High · High · None
Fix status
Fixed

Attack profile from CVSS 4.0 · CNA. Fix status from CNA. Impact type from CWE-79.

Summary

A vulnerability has been identified in Teamcenter V2412 (All versions < V2412.0013), Teamcenter V2506 (All versions < V2506.0010), Teamcenter V2512 (All versions < V2512.2607), Teamcenter V2606 (All versions < V2606.2607). Affected applications do not properly encode user-supplied input reflected into HTML attribute contexts within the authentication redirect flow (/auth/ endpoint). This could allow an unauthenticated remote attacker to inject arbitrary JavaScript into the browser of an authenticated user who loads a crafted URL, enabling the attacker to perform actions within the victim's Teamcenter session.

Why it matters now

Exploitation None reported CISA SSVC · not in CISA KEV
EPSS 0.00393 33rd percentileScored 2026-11-07
Fix Fixed Teamcenter V2412 (Siemens): V2412.0013Teamcenter V2506 (Siemens): V2506.0010+2 more products

SSVC decision points

CISA ADP · SSVC 2.0.3

Exploitation
None
Automatable
No
Technical impact
Partial

The decision (Track, Attend, Act) also depends on your mission and well-being impact; see CISA's SSVC guide.

Affected products

VendorProductAffected versionsFixed inStatusSource
SiemensTeamcenter V2412before V2412.0013V2412.0013Patch availableCNA
SiemensTeamcenter V2506before V2506.0010V2506.0010Patch availableCNA
SiemensTeamcenter V2512before V2512.2607V2512.2607Patch availableCNA
SiemensTeamcenter V2606before V2606.2607V2606.2607Patch availableCNA
  • Teamcenter V2412 VendorSiemens Affected before V2412.0013 Fixed in V2412.0013 Patch available CNA
  • Teamcenter V2506 VendorSiemens Affected before V2506.0010 Fixed in V2506.0010 Patch available CNA
  • Teamcenter V2512 VendorSiemens Affected before V2512.2607 Fixed in V2512.2607 Patch available CNA
  • Teamcenter V2606 VendorSiemens Affected before V2606.2607 Fixed in V2606.2607 Patch available CNA

Remediation

  • Fix · CNA Teamcenter V2412 (Siemens) Fixed in V2412.0013
  • Fix · CNA Teamcenter V2506 (Siemens) Fixed in V2506.0010
  • Fix · CNA Teamcenter V2512 (Siemens) Fixed in V2512.2607
  • Fix · CNA Teamcenter V2606 (Siemens) Fixed in V2606.2607

Timeline

  1. 2026-10-02 Threatist record created from CVE-2026-58113
  2. 2026-10-03 Alias added: GHSA-66wm-wchr-375j

References

  • TI-2026-20057 Authentication bypass in Fortinet FortiWeb KEVCVSS 3.1CRITICAL 9.4
  • TI-2025-26358 tls: fix handling of zero-length records on the rx_list KEVCVSS 3.1CRITICAL 9.8
  • TI-2025-18911 Heap-based buffer overflow in Fortinet FortiSwitchManager KEVCVSS 3.1CRITICAL 9.8
  • TI-2025-09686 Type confusion in Google Chrome KEVCVSS 3.1CRITICAL 9.8
  • TI-2022-07142 Code injection in Spring Framework KEVCVSS 3.1CRITICAL 9.8
  • TI-2021-19919 Apache Log4j2 JNDI features do not protect against attacker controlled LDAP and other JNDI related endpoints KEVCVSS 3.1CRITICAL 10.0
See all 2487 →