Server-side request forgery in Mobi-Com Polska Sp. z o.o. stunnel
Key facts
- Attack vector
- Network
- Privileges required
- Low
- User interaction
- None
- Attack complexity
- Low
- Impact type
- —
- Confidentiality · integrity · availability
- Low · Low · None
- Fix status
- Partial Red Hat: 3 without a fix
Attack profile from CVSS 3.1 · CNA. Fix status from CNA and Red Hat.
Summary
A Server-Side Request Forgery (SSRF) bypass vulnerability exists in “stunnel” 5.79 and lower when configured in SOCKS proxy mode. This flaw allows a client to bypass intended localhost restrictions by using IPv4-mapped IPv6 addresses (e.g., “::ffff:127.0.0.1”) or unspecified addresses ("0.0.0.0", "::"), enabling access to loopback-only services on the "stunnel" host that should not be network-reachable.
Why it matters now
SSVC decision points
CISA ADP · SSVC 2.0.3
- Exploitation
- Poc
- Automatable
- No
- Technical impact
- Partial
The decision (Track, Attend, Act) also depends on your mission and well-being impact; see CISA's SSVC guide.
Affected products
| Vendor | Product | Affected versions | Fixed in | Status | Source |
|---|---|---|---|---|---|
| Mobi-Com Polska Sp. z o.o. | stunnel | 5.25 to before 5.80 | 5.80 | Patch available | CNA |
| Red Hat | Red Hat Enterprise Linux 10 | — | — | No fix listed | CNA |
| Red Hat | Red Hat Enterprise Linux 6 | — | — | Not affected | CNA |
| Red Hat | Red Hat Enterprise Linux 7 | — | — | Not affected | CNA |
| Red Hat | Red Hat Enterprise Linux 8 | — | — | No fix listed | CNA |
| Red Hat | Red Hat Enterprise Linux 9 | — | — | No fix listed | CNA |
- stunnel VendorMobi-Com Polska Sp. z o.o. Affected 5.25 to before 5.80 Fixed in 5.80 Patch available CNA
- Red Hat Enterprise Linux 10 VendorRed Hat Affected — Fixed in — No fix listed CNA
- Red Hat Enterprise Linux 6 VendorRed Hat Affected — Fixed in — Not affected CNA
- Red Hat Enterprise Linux 7 VendorRed Hat Affected — Fixed in — Not affected CNA
- Red Hat Enterprise Linux 8 VendorRed Hat Affected — Fixed in — No fix listed CNA
- Red Hat Enterprise Linux 9 VendorRed Hat Affected — Fixed in — No fix listed CNA
Remediation
- Fix · CNA stunnel (Mobi-Com Polska Sp. z o.o.) Fixed in 5.80
Fixed in the same release
Records fixed by the same vendor advisory or release, as the CNA lists them.
- Release ·
Mobi-Com Polska Sp. z o.o. stunnel 5.80
2 records Highest priority Priority MEDIUM 1 MEDIUM, 1 LOW
Other records, highest priority first
- TI-2026-49171 Stunnel: stack-based out-of-bounds read/write in stunnel s_vlog via oversized log messagePriority LOW 35
Vendor assessments
Red Hat
Red Hat rating: Moderate. Red Hat's page for this CVE →
| Product | Status | Plan or fix |
|---|---|---|
| Red Hat Enterprise Linux 10 | Affected | No fix yet: Fix deferred |
| Red Hat Enterprise Linux 8 | Affected | No fix yet: Fix deferred |
| Red Hat Enterprise Linux 9 | Affected | No fix yet: Fix deferred |
Not affected: 2 products
- Red Hat Enterprise Linux 6
- Red Hat Enterprise Linux 7
Timeline
- 2026-10-02 Threatist record created from CVE-2026-70367
- 2026-10-03 Alias added: GHSA-2x69-8qrg-27gr
References
More Mobi-Com Polska Sp. z o.o. vulnerabilities
- TI-2026-49171 Stunnel: stack-based out-of-bounds read/write in stunnel s_vlog via oversized log message CVSS 3.1MEDIUM 6.5
Sources
- CVE-2026-70367 · CVE Program
- CVE-2026-70367 · NVD
- FIRST EPSS
- GHSA-2x69-8qrg-27gr · GitHub Advisory Database · CC BY 4.0
- CVE-2026-70367 · Red Hat security data · CC BY 4.0
This product uses the NVD API but is not endorsed or certified by the NVD. Sources and licences