Read the docs
TI-2026-49170 Aliases CVE-2026-70367GHSA-2x69-8qrg-27gr

Server-side request forgery in Mobi-Com Polska Sp. z o.o. stunnel

Priority MEDIUM 58CWE-918Published · Updated

Key facts

Attack vector
Network
Privileges required
Low
User interaction
None
Attack complexity
Low
Impact type
—
Confidentiality · integrity · availability
Low · Low · None
Fix status
Partial Red Hat: 3 without a fix

Attack profile from CVSS 3.1 · CNA. Fix status from CNA and Red Hat.

Summary

A Server-Side Request Forgery (SSRF) bypass vulnerability exists in “stunnel” 5.79 and lower when configured in SOCKS proxy mode. This flaw allows a client to bypass intended localhost restrictions by using IPv4-mapped IPv6 addresses (e.g., “::ffff:127.0.0.1”) or unspecified addresses ("0.0.0.0", "::"), enabling access to loopback-only services on the "stunnel" host that should not be network-reachable.

Why it matters now

Exploitation Proof of concept CISA SSVC · not in CISA KEV
EPSS 0.00224 13th percentileScored 2026-11-07
Fix Partial stunnel (Mobi-Com Polska Sp. z o.o.): 5.80Red Hat: 3 without a fix

SSVC decision points

CISA ADP · SSVC 2.0.3

Exploitation
Poc
Automatable
No
Technical impact
Partial

The decision (Track, Attend, Act) also depends on your mission and well-being impact; see CISA's SSVC guide.

Affected products

VendorProductAffected versionsFixed inStatusSource
Mobi-Com Polska Sp. z o.o.stunnel5.25 to before 5.805.80Patch availableCNA
Red HatRed Hat Enterprise Linux 10——No fix listedCNA
Red HatRed Hat Enterprise Linux 6——Not affectedCNA
Red HatRed Hat Enterprise Linux 7——Not affectedCNA
Red HatRed Hat Enterprise Linux 8——No fix listedCNA
Red HatRed Hat Enterprise Linux 9——No fix listedCNA
  • stunnel VendorMobi-Com Polska Sp. z o.o. Affected 5.25 to before 5.80 Fixed in 5.80 Patch available CNA
  • Red Hat Enterprise Linux 10 VendorRed Hat Affected — Fixed in — No fix listed CNA
  • Red Hat Enterprise Linux 6 VendorRed Hat Affected — Fixed in — Not affected CNA
  • Red Hat Enterprise Linux 7 VendorRed Hat Affected — Fixed in — Not affected CNA
  • Red Hat Enterprise Linux 8 VendorRed Hat Affected — Fixed in — No fix listed CNA
  • Red Hat Enterprise Linux 9 VendorRed Hat Affected — Fixed in — No fix listed CNA

CPE names CNA · 5

CPEVersionsRoleVendor
cpe:/a:redhat:enterprise_linux:1010—Red Hat
cpe:/o:redhat:rhel_els:66—Red Hat
cpe:/o:redhat:rhel_els:77—Red Hat
cpe:/a:redhat:enterprise_linux:88—Red Hat
cpe:/a:redhat:enterprise_linux:99—Red Hat
  • cpe:/a:redhat:enterprise_linux:10 Versions 10 — ·Red Hat
  • cpe:/o:redhat:rhel_els:6 Versions 6 — ·Red Hat
  • cpe:/o:redhat:rhel_els:7 Versions 7 — ·Red Hat
  • cpe:/a:redhat:enterprise_linux:8 Versions 8 — ·Red Hat
  • cpe:/a:redhat:enterprise_linux:9 Versions 9 — ·Red Hat

Remediation

  • Fix · CNA stunnel (Mobi-Com Polska Sp. z o.o.) Fixed in 5.80

Fixed in the same release

Records fixed by the same vendor advisory or release, as the CNA lists them.

  • Release ·

    Mobi-Com Polska Sp. z o.o. stunnel 5.80

    2 records Highest priority Priority MEDIUM 1 MEDIUM, 1 LOW

    Other records, highest priority first

    • TI-2026-49171 Stunnel: stack-based out-of-bounds read/write in stunnel s_vlog via oversized log messagePriority LOW 35

Vendor assessments

Red Hat

Red Hat rating: Moderate. Red Hat's page for this CVE →

ProductStatusPlan or fix
Red Hat Enterprise Linux 10AffectedNo fix yet: Fix deferred
Red Hat Enterprise Linux 8AffectedNo fix yet: Fix deferred
Red Hat Enterprise Linux 9AffectedNo fix yet: Fix deferred
Not affected: 2 products
  • Red Hat Enterprise Linux 6
  • Red Hat Enterprise Linux 7

Timeline

  1. 2026-10-02 Threatist record created from CVE-2026-70367
  2. 2026-10-03 Alias added: GHSA-2x69-8qrg-27gr

References

  • TI-2026-49171 Stunnel: stack-based out-of-bounds read/write in stunnel s_vlog via oversized log message CVSS 3.1MEDIUM 6.5

Sources