Read the docs
TI-2026-58752 Aliases CVE-2026-85628GHSA-mmjj-x36j-f536

Cleartext Transmission of Sensitive Information in the Pairing Process vulnerability

Priority LOW 29CWE-319Published · Updated

Key facts

Attack vector
Adjacent network
Privileges required
None
User interaction
Passive
Attack complexity
Low
Attack requirements
Present
Impact type
Information disclosure
Confidentiality · integrity · availability
High · None · None
Fix status
Fixed

Attack profile from CVSS 4.0 · CNA. Fix status from CNA. Impact type from CWE-319.

Summary

Transmission of the home Wi-Fi credentials without encryption during the pairing process between the DuoxMe application and VEO and VEO-XS Wi-Fi monitors, in versions prior to 4.3.4 of the application and 01.50.001 of the monitor firmware, allows an attacker on the Wi-Fi Direct network to intercept the network password.

Why it matters now

Exploitation None reported CISA SSVC · not in CISA KEV
EPSS 0.00088 0th percentileScored 2026-11-07
Fix Fixed DuoxMe (Fermax Electronica S.A.U.): 4.3.4DUOX PLUS monitor firmware (VEO Wi-Fi range) (Fermax Electronica S.A.U.): 01.50.001

SSVC decision points

CISA ADP · SSVC 2.0.3

Exploitation
None
Automatable
No
Technical impact
Partial

The decision (Track, Attend, Act) also depends on your mission and well-being impact; see CISA's SSVC guide.

Affected products

VendorProductAffected versionsFixed inStatusSource
Fermax Electronica S.A.U.DuoxMebefore 4.3.44.3.4Patch availableCNA
Fermax Electronica S.A.U.DUOX PLUS monitor firmware (VEO Wi-Fi range)before 01.50.00101.50.001Patch availableCNA

Remediation

  • Fix · CNA DuoxMe (Fermax Electronica S.A.U.) Fixed in 4.3.4
  • Fix · CNA DUOX PLUS monitor firmware (VEO Wi-Fi range) (Fermax Electronica S.A.U.) Fixed in 01.50.001

Fixed in the same release

Records fixed by the same vendor advisory or release, as the CNA lists them.

  • Advisory ·

    Fermax Electronica S.A.U. DUOX PLUS monitor firmware (VEO Wi-Fi range), DuoxMe — fermax.com/security-advisories

    4 records Highest priority Priority LOW 4 LOW

    Other records, highest priority first

    • TI-2026-59232 Improper Verification of the Firmware Signature vulnerabilityPriority LOW 35
    • TI-2026-59168 Improper Certificate Validation in the Firmware Download vulnerabilityPriority LOW 34
    • TI-2026-59150 Cleartext storage of sensitive information in Fermax Electronica S.A.U. DuoxMePriority LOW 29

Timeline

  1. 2026-10-02 Threatist record created from CVE-2026-85628
  2. 2026-10-03 Alias added: GHSA-mmjj-x36j-f536

References

  • TI-2026-59232 Improper Verification of the Firmware Signature vulnerability CVSS 4.0HIGH 7.7
  • TI-2026-59168 Improper Certificate Validation in the Firmware Download vulnerability CVSS 4.0HIGH 7.7
  • TI-2026-59150 Cleartext storage of sensitive information in Fermax Electronica S.A.U. DuoxMe CVSS 4.0MEDIUM 6.9

Sources