Read the docs
TI-2026-61919 Aliases CVE-2026-91191GHSA-q7r9-65j5-94xj

Lantronix G520 Series Cellular Gateway Improper Verification of Cryptographic Signature

Priority LOW 35CWE-347Published · Updated

Key facts

Attack vector
Network
Privileges required
None
User interaction
Passive
Attack complexity
Low
Attack requirements
Present
Impact type
Security bypass
Confidentiality · integrity · availability
High · High · High
Fix status
No fix listed

Attack profile from CVSS 4.0 · CNA. Fix status from CNA. Impact type from CWE-347.

Summary

The device's update mechanism includes conditions that allow unauthorized software packages to be accepted as authentic. During the boot process, the stock done function disables signature verification in the OPKG configuration before restoring optional packages from a writable, unsigned feed. Separately, the publicly distributed SDK contains the production private key whose corresponding public key is trusted by both stable and beta firmware builds. Either issue undermines package authenticity, and together they allow an attacker to provide packages that appear valid to the system. Even if signature enforcement is restored, the exposed production key enables an attacker to generate signatures that the device will continue to trust. An attacker who can supply a malicious package may be able to execute arbitrary code with root privileges during installation.

Why it matters now

Exploitation None reported CISA SSVC · not in CISA KEV
EPSS 0.00222 12th percentileScored 2026-11-07
Fix No fix listed No fixed version in the sources yet

SSVC decision points

CISA ADP · SSVC 2.0.3

Exploitation
None
Automatable
No
Technical impact
Total

The decision (Track, Attend, Act) also depends on your mission and well-being impact; see CISA's SSVC guide.

Affected products

VendorProductAffected versionsFixed inStatusSource
LantronixG520 Series2.6.0.4R6 stable—No fix listedCNA
  • G520 Series VendorLantronix Affected 2.6.0.4R6 stable Fixed in — No fix listed CNA

Remediation

No fixed version listed by the sources yet.

Timeline

  1. 2026-10-02 Threatist record created from CVE-2026-91191
  2. 2026-10-03 Alias added: GHSA-q7r9-65j5-94xj

References

  • TI-2025-41112 Lantronix EDS5000, G520, and X300 OS Command Injection KEVCVSS 4.0CRITICAL 9.3
  • TI-2021-04926 OS command injection in Lantronix CVSS 3.1CRITICAL 9.9
  • TI-2021-04937 Stack-based buffer overflow in Lantronix CVSS 3.1CRITICAL 9.9
  • TI-2026-55403 Lantronix Autonomous Out-of-Band Devices Unauthenticated Authentication Bypass via snprintf Path Truncation CVSS 4.0CRITICAL 10.0
  • TI-2021-04928 OS command injection in Lantronix CVSS 3.1CRITICAL 9.9
  • TI-2021-04917 OS command injection in Lantronix CVSS 3.1CRITICAL 9.9
See all 61 →

Sources