Read the docs
TI-2026-65899 Aliases CVE-2026-86326GHSA-pccp-468g-6mp8

Improper signature verification in Moxa MGate MB3170 Series

Priority LOW 38CWE-347Published · Updated

Key facts

Attack vector
Network
Privileges required
High
User interaction
None
Attack complexity
Low
Attack requirements
None
Impact type
Security bypass
Confidentiality · integrity · availability
High · High · High
Fix status
No fix listed

Attack profile from CVSS 4.0 · CNA. Fix status from CNA. Impact type from CWE-347.

Summary

An improper verification of cryptographic signature vulnerability exists in protocol gateways because the device does not properly verify the cryptographic authenticity of firmware images before installation. An attacker with high privileges and access to the firmware update interface could provide a specially crafted or modified firmware image, causing it to be installed on the device. Successful exploitation could allow the attacker to execute unauthorized code, compromise the integrity and availability of the device, and persist malicious modifications across subsequent firmware updates.

Why it matters now

Exploitation None reported CISA SSVC · not in CISA KEV
EPSS 0.00188 8th percentileScored 2026-11-07
Fix No fix listed No fixed version in the sources yet

SSVC decision points

CISA ADP · SSVC 2.0.3

Exploitation
None
Automatable
No
Technical impact
Total

The decision (Track, Attend, Act) also depends on your mission and well-being impact; see CISA's SSVC guide.

Affected products

VendorProductAffected versionsFixed inStatusSource
MoxaMGate MB3170 Series1.0—No fix listedCNA
MoxaMGate MB3270 Series1.0—No fix listedCNA
  • MGate MB3170 Series VendorMoxa Affected 1.0 Fixed in — No fix listed CNA
  • MGate MB3270 Series VendorMoxa Affected 1.0 Fixed in — No fix listed CNA

Remediation

No fixed version listed by the sources yet.

Fixed in the same release

Records fixed by the same vendor advisory or release, as the CNA lists them.

  • Advisory ·

    Moxa MGate MB3170 Series, MGate MB3270 Series — moxa.com/en/support/product-support/security-advisory/mpsa-…

    2 records Highest priority Priority MEDIUM 1 MEDIUM, 1 LOW

    Other records, highest priority first

    • TI-2026-65898 Stack-based buffer overflow in Moxa MGate MB3170 SeriesPriority MEDIUM 42

Timeline

  1. 2026-10-02 Threatist record created from CVE-2026-86326
  2. 2026-10-03 Alias added: GHSA-pccp-468g-6mp8

References

  • TI-2021-17455 Hard-coded credentials in Moxa MXView Series CVSS 3.1CRITICAL 9.8
  • TI-2010-04465 Stack-based buffer overflow in a certain ActiveX control in MediaDBPlayback.DLL 2.2.0.5… CVSS 2.0HIGH 10.0
  • TI-2022-19087 A denial of service vulnerability exists in the web server functionality of Moxa SDS-3008… CVSS 3.1HIGH 7.5
  • TI-2016-07634 Missing brute-force protection in Moxa NPort CVSS 3.1CRITICAL 9.8
  • TI-2021-17457 Cleartext transmission of sensitive information in Moxa MXView Series CVSS 3.1HIGH 7.5
  • TI-2022-19326 Information disclosure in Moxa SDS-3008 Series Industrial Ethernet Switch CVSS 3.1MEDIUM 5.3
See all 328 →

Sources