Summary

Brocade ASCG before 3.5.0 evaluates submitted form data before it is validated. An authenticated user who submits a configuration form can have crafted input executed as code (CWE-95), so a user with basic access can execute arbitrary code on the server and take control of the application.

Written with Claude Haiku 5.5 from the sources below · 2026-10-29

Description from the CNA

Brocade ASCG before 3.5.0 improperly processes user input by evaluating form data prior to validation. When an authenticated user submits a configuration form, the submitted text could immediately be processed. A malicious actor with basic access can supply crafted input to execute arbitrary code on the server and take control of the application.

Why it matters now

Exploitation None reported CISA SSVC · not in CISA KEV
EPSS 0.00293 22nd percentileScored 2026-11-07
Fix Fixed Brocade Active Support Connectivity Gateway (Brocade): 3.5.0

SSVC decision points

CISA ADP · SSVC 2.0.3

Exploitation
None
Automatable
No
Technical impact
Total

The decision (Track, Attend, Act) also depends on your mission and well-being impact; see CISA's SSVC guide.

Affected products

VendorProductAffected versionsFixed inStatusSource
BrocadeBrocade Active Support Connectivity Gatewaybefore 3.5.03.5.0Patch availableCNA
  • Brocade Active Support Connectivity Gateway VendorBrocade Affected before 3.5.0 Fixed in 3.5.0 Patch available CNA

CPE configurations NVD · 1

CPEVersionsRoleVendor
cpe:2.3:a:broadcom:brocade_active_support_connectivity_gateway:*:*:*:*:*:*:*:*before 3.5.0VulnerableBroadcom
  • cpe:2.3:a:broadcom:brocade_active_support_connectivity_gateway:*:*:*:*:*:*:*:* Versions before 3.5.0 Vulnerable ·Broadcom

Remediation

Update Brocade Active Support Connectivity Gateway to version 3.5.0.

Written with Claude Haiku 5.5 from the sources below · 2026-10-29

  • Fix · CNA Brocade Active Support Connectivity Gateway (Brocade) Fixed in 3.5.0

Fixed in the same release

Records fixed by the same vendor advisory or release, as the CNA lists them.

  • Release ·

    Brocade Active Support Connectivity Gateway 3.5.0

    12 records Highest priority Priority LOW 12 LOW

    Other records, highest priority first

    • TI-2026-69450 Missing authentication in Brocade ASCG management servicePriority LOW 39
    • TI-2026-69448 Path traversal in Brocade ASCG HTTP service allows arbitrary file accessPriority LOW 39
    • TI-2026-69446 Missing authentication in Brocade ASCG data collector servicePriority LOW 39

Timeline

  1. 2026-10-08 Threatist record created from CVE-2026-85486
  2. 2026-10-08 CISA SSVC decision points changed
  3. 2026-10-08 Priority changed: MEDIUM → LOW
  4. 2026-10-15 Alias added: GHSA-vq54-9wr8-28vj
  5. 2026-10-15 CVSS score added · NVD

References

  • TI-2025-01721 Code injection exposure in Fabric OS 9.1.0 through 9.1.1d6 KEVCVSS 4.0HIGH 8.6
  • TI-2016-06760 Path traversal in Brocade Network Advisor versions released prior to and including 14.0.2 CVSS 3.0CRITICAL 9.8
  • TI-2024-19729 hard-coded credentials in the documentation that appear as the appliance root password CVSS 3.1CRITICAL 9.8
  • TI-2016-06762 Path traversal in Brocade Network Advisor versions released prior to and including 14.0.2 CVSS 3.0HIGH 7.5
  • TI-2018-04739 OS command injection in Brocade Network Advisor CVSS 3.0CRITICAL 9.8
  • TI-2016-06761 Path traversal in Brocade Network Advisor versions released prior to and including 14.0.2 CVSS 3.0HIGH 7.5
See all 191 →

Sources