Read the docs
TI-2026-70077 Aliases CVE-2026-39460

Red Lion Controls N-Tron 700 Series Insufficiently Protected Credentials

Priority MEDIUM 42CWE-522Published · Updated

Key facts

Attack vector
Network
Privileges required
Low
User interaction
None
Attack complexity
Low
Attack requirements
None
Impact type
Information disclosure
Confidentiality · integrity · availability
High · High · None
Fix status
Fixed

Attack profile from CVSS 4.0 · CNA. Fix status from CNA. Impact type from CWE-522.

Summary

Red Lion Controls 700 Series firmware before 3.11.0 and bootloader before 2.0.6.1 store usernames and passwords, including default factory credentials, in plaintext in the configuration file (CWE-522). A remote attacker without authentication can start a TFTP transfer of that file through SNMP, exposing the credentials.

Written with Claude Haiku 5.5 from the sources below · 2026-10-29

Description from the CNA

Usernames and passwords, including the default factory credentials, are stored in plaintext within the configuration file. With administrator rights, the configuration file can be viewed through the CLI or they can be exported from the device through a TFTP transfer from the web interface. A TFTP transfer can be initiated through SNMP which does not require authentication.

Why it matters now

Exploitation None reported CISA SSVC · not in CISA KEV
EPSS 0.00291 21st percentileScored 2026-11-07
Fix Fixed 700 Series (Red Lion Controls): Firmware Versions 3.11.0, Bootloader Versions 2.0.6.1, 3.11.1

SSVC decision points

CISA ADP · SSVC 2.0.3

Exploitation
None
Automatable
No
Technical impact
Total

The decision (Track, Attend, Act) also depends on your mission and well-being impact; see CISA's SSVC guide.

Affected products

VendorProductAffected versionsFixed inStatusSource
Red Lion Controls700 Seriesbefore Firmware Versions 3.11.0; before Bootloader Versions 2.0.6.1Firmware Versions 3.11.0, Bootloader Versions 2.0.6.1, 3.11.1Patch availableCNA
  • 700 Series VendorRed Lion Controls Affected before Firmware Versions 3.11.0; before Bootloader Versions 2.0.6.1 Fixed in Firmware Versions 3.11.0, Bootloader Versions 2.0.6.1, 3.11.1 Patch available CNA

Remediation

Fixed versions for Red Lion Controls 700 Series are firmware 3.11.0 and 3.11.1 and bootloader 2.0.6.1.

Written with Claude Haiku 5.5 from the sources below · 2026-10-29

  • Fix · CNA 700 Series (Red Lion Controls) Fixed in Firmware Versions 3.11.0, Bootloader Versions 2.0.6.1, 3.11.1

Fixed in the same release

Records fixed by the same vendor advisory or release, as the CNA lists them.

  • Release ·

    Red Lion Controls 700 Series Bootloader Versions 2.0.6.1, Firmware Versions 3.11.0

    7 records Highest priority Priority MEDIUM 4 MEDIUM, 3 LOW

    Other records, highest priority first

    • TI-2026-70075 Missing authentication in Red Lion N-Tron 700 Series over SNMPPriority MEDIUM 42
    • TI-2026-70071 Recoverable password storage in Red Lion Controls N-Tron 700 SeriesPriority MEDIUM 41
    • TI-2026-70073 Hard-coded admin credentials in Red Lion N-Tron 700 Series devicesPriority MEDIUM 40

Timeline

  1. 2026-10-09 Threatist record created from CVE-2026-39460
  2. 2026-10-13 CISA SSVC decision points changed

References

  • TI-2023-22865 Red Lion Controls Sixnet RTU Authentication Bypass Using An Alternative Path Or Channel CVSS 3.1CRITICAL 10.0
  • TI-2023-21028 Red Lion Controls Sixnet RTU Exposed Dangerous Method Or Function CVSS 3.1CRITICAL 10.0
  • TI-2016-07615 Hard-coded credentials in Red Lion Controls Sixnet-Managed Industrial Switches CVSS 3.0CRITICAL 10.0
  • TI-2026-70075 Missing authentication in Red Lion N-Tron 700 Series over SNMP CVSS 4.0CRITICAL 9.3
  • TI-2026-70071 Recoverable password storage in Red Lion Controls N-Tron 700 Series CVSS 4.0CRITICAL 9.3
  • TI-2026-70073 Hard-coded admin credentials in Red Lion N-Tron 700 Series devices CVSS 4.0CRITICAL 9.2
See all 10 →

Sources

This product uses the NVD API but is not endorsed or certified by the NVD. Sources and licences