Cross-site scripting in Edimax BR-6208AC formFilter
Key facts
- Attack vector
- Network
- Privileges required
- High
- User interaction
- Passive
- Attack complexity
- Low
- Attack requirements
- None
- Impact type
- Cross-site scripting, Code execution
- Confidentiality · integrity · availability
- None · Low · None
- Fix status
- No fix listed
Attack profile from CVSS 4.0 · CNA. Fix status from CNA. Impact type from CWE-79 and CWE-94.
Summary
Edimax BR-6208AC from 1.32 contains a cross-site scripting flaw (CWE-79) in an unknown function of the /goform/formFilter file. Improper neutralization of input lets a remote attacker with high privileges and user interaction inject script into the web interface. A public exploit is linked in the references.
Written with Claude Haiku 5.5 from the sources below · 2026-10-29
Description from the CNA
A vulnerability was identified in Edimax BR-6208AC 1.32. Affected is an unknown function of the file /goform/formFilter. Such manipulation leads to cross site scripting. The attack can be executed remotely. The exploit is publicly available and might be used. The vendor was contacted early about this disclosure but did not respond in any way.
Why it matters now
SSVC decision points
CISA ADP · SSVC 2.0.3
- Exploitation
- Poc
- Automatable
- No
- Technical impact
- Partial
The decision (Track, Attend, Act) also depends on your mission and well-being impact; see CISA's SSVC guide.
Affected products
Remediation
The sources list no fixed version for Edimax BR-6208AC.
Written with Claude Haiku 5.5 from the sources below · 2026-10-29
Timeline
- 2026-10-12 Threatist record created from CVE-2026-108933
- 2026-10-13 Alias added: GHSA-43w7-vfgx-x3g5
- 2026-10-16 CISA SSVC decision points changed
- 2026-10-16 Priority changed: LOW → MEDIUM
References
More Edimax vulnerabilities
- TI-2025-01129 Edimax IC-7100 IP Camera OS Command Injection KEVCVSS 4.0CRITICAL 9.3
- TI-2026-85269 Edimax BR-6208AC mp command injection CVSS 4.0CRITICAL 10.0
- TI-2026-71231 Command injection in Edimax BR-6208AC via formWlanMP CVSS 4.0CRITICAL 10.0
- TI-2026-71230 Command injection in Edimax BR-6208AC via tftpsIP argument CVSS 4.0CRITICAL 10.0
- TI-2025-28873 EDIMAX CV7428NS v1.20 was discovered to contain a remote code execution (RCE)… CVSS 3.1CRITICAL 9.8
- TI-2025-20734 Edimax AC1200 Wave 2 Dual-Band Gigabit Router BR-6478AC V3 1.0.15 was discovered to… CVSS 3.1CRITICAL 9.8
Sources
- CVE-2026-108933 · CVE Program
- CVE-2026-108933 · NVD
- FIRST EPSS
- GHSA-43w7-vfgx-x3g5 · GitHub Advisory Database · CC BY 4.0
This product uses the NVD API but is not endorsed or certified by the NVD. Sources and licences