Read the docs

Cross-site scripting in Edimax BR-6208AC HTTP Blocking page

Priority MEDIUM 55CWE-79Published · Updated

Key facts

Attack vector
Network
Privileges required
High
User interaction
Passive
Attack complexity
Low
Attack requirements
None
Impact type
Cross-site scripting, Code execution
Confidentiality · integrity · availability
None · Low · None
Fix status
No fix listed

Attack profile from CVSS 4.0 · CNA. Fix status from CNA. Impact type from CWE-79 and CWE-94.

Summary

An unknown functionality of the file /goform/formUrlb in the HTTP Blocking Page component of Edimax BR-6208AC 1.32 is affected by cross-site scripting (CWE-79). An attacker with high privileges and user interaction can inject script that runs in the browser of a user, and the attack can be carried out remotely. A public exploit has been released and may be used for attacks.

Written with Claude Haiku 5.5 from the sources below · 2026-10-29

Description from the CNA

A security flaw has been discovered in Edimax BR-6208AC 1.32. Affected by this vulnerability is an unknown functionality of the file /goform/formUrlb of the component HTTP Blocking Page. Performing a manipulation results in cross site scripting. The attack is possible to be carried out remotely. The exploit has been released to the public and may be used for attacks. The vendor was contacted early about this disclosure but did not respond in any way.

Why it matters now

Exploitation Proof of concept CISA SSVC · not in CISA KEV
EPSS 0.00202 10th percentileScored 2026-11-08
Public exploit Yes 1 exploit referenceTagged by the CNA
Fix No fix listed No fixed version in the sources yet

SSVC decision points

CISA ADP · SSVC 2.0.3

Exploitation
Poc
Automatable
No
Technical impact
Partial

The decision (Track, Attend, Act) also depends on your mission and well-being impact; see CISA's SSVC guide.

Affected products

VendorProductAffected versionsFixed inStatusSource
EdimaxBR-6208AC1.32—No fix listedCNA
  • BR-6208AC VendorEdimax Affected 1.32 Fixed in — No fix listed CNA

CPE names CNA · 1

CPEVersionsRoleVendor
cpe:2.3:o:edimax:br-6208ac_firmware:*:*:*:*:*:*:*:*——Edimax
  • cpe:2.3:o:edimax:br-6208ac_firmware:*:*:*:*:*:*:*:* Versions — — ·Edimax

Remediation

The sources list no fixed version for Edimax BR-6208AC.

Written with Claude Haiku 5.5 from the sources below · 2026-10-29

Timeline

  1. 2026-10-12 Threatist record created from CVE-2026-108934
  2. 2026-10-13 Alias added: GHSA-v2hh-gcwr-7r8h
  3. 2026-10-13 CISA SSVC decision points changed
  4. 2026-10-13 Priority changed: LOW → MEDIUM

References

  • TI-2025-01129 Edimax IC-7100 IP Camera OS Command Injection KEVCVSS 4.0CRITICAL 9.3
  • TI-2026-85269 Edimax BR-6208AC mp command injection CVSS 4.0CRITICAL 10.0
  • TI-2026-71231 Command injection in Edimax BR-6208AC via formWlanMP CVSS 4.0CRITICAL 10.0
  • TI-2026-71230 Command injection in Edimax BR-6208AC via tftpsIP argument CVSS 4.0CRITICAL 10.0
  • TI-2025-28873 EDIMAX CV7428NS v1.20 was discovered to contain a remote code execution (RCE)… CVSS 3.1CRITICAL 9.8
  • TI-2025-20734 Edimax AC1200 Wave 2 Dual-Band Gigabit Router BR-6478AC V3 1.0.15 was discovered to… CVSS 3.1CRITICAL 9.8
See all 158 →