Read the docs
TI-2026-71568 Aliases CVE-2026-44414GHSA-9xh9-64gc-w6jh

Path traversal in Siemens Industrial Edge devices

Priority LOW 31CWE-35Published · Updated

Key facts

Attack vector
Network
Privileges required
High
User interaction
None
Attack complexity
Low
Attack requirements
Present
Impact type
—
Confidentiality · integrity · availability
High · None · None
Fix status
Fixed

Attack profile from CVSS 4.0 · CNA. Fix status from CNA.

Summary

Siemens Industrial Edge Cloud Device (IECD) from 0 before V1.28.1, Industrial Edge Device Kit - arm64 V1.10, Industrial Edge Device Kit - arm64 V1.11, Industrial Edge Device Kit - arm64 V1.12, Industrial Edge Device Kit - arm64 V1.13, and other products are affected. The affected systems do not properly restrict access to internal APIs and paths (CWE-35). An authenticated remote attacker can access sensitive internal information, which in the worst case could lead to unauthorized access to the system.

Written with Claude Haiku 5.5 from the sources below · 2026-10-27

Description from the CNA

A vulnerability has been identified in Industrial Edge Cloud Device (IECD), Industrial Edge Device Kit - arm64 V1.10, Industrial Edge Device Kit - arm64 V1.11, Industrial Edge Device Kit - arm64 V1.12, Industrial Edge Device Kit - arm64 V1.13, Industrial Edge Device Kit - arm64 V1.14, Industrial Edge Device Kit - arm64 V1.15, Industrial Edge Device Kit - arm64 V1.16, Industrial Edge Device Kit - arm64 V1.17, Industrial Edge Device Kit - arm64 V1.18, Industrial Edge Device Kit - arm64 V1.19, Industrial Edge Device Kit - arm64 V1.20, Industrial Edge Device Kit - arm64 V1.21, Industrial Edge Device Kit - arm64 V1.22, Industrial Edge Device Kit - arm64 V1.23, Industrial Edge Device Kit - arm64 V1.24, Industrial Edge Device Kit - arm64 V1.25, Industrial Edge Device Kit - arm64 V1.26, Industrial Edge Device Kit - arm64 V1.27, Industrial Edge Device Kit - arm64 V1.28, Industrial Edge Device Kit - arm64 V1.5, Industrial Edge Device Kit - arm64 V1.6, Industrial Edge Device Kit - arm64 V1.7, Industrial Edge Device Kit - arm64 V1.8, Industrial Edge Device Kit - arm64 V1.9, Industrial Edge Device Kit - x86-64 V1.10, Industrial Edge Device Kit - x86-64 V1.11, Industrial Edge Device Kit - x86-64 V1.12, Industrial Edge Device Kit - x86-64 V1.13, Industrial Edge Device Kit - x86-64 V1.14, Industrial Edge Device Kit - x86-64 V1.15, Industrial Edge Device Kit - x86-64 V1.16, Industrial Edge Device Kit - x86-64 V1.17, Industrial Edge Device Kit - x86-64 V1.18, Industrial Edge Device Kit - x86-64 V1.19, Industrial Edge Device Kit - x86-64 V1.20, Industrial Edge Device Kit - x86-64 V1.21, Industrial Edge Device Kit - x86-64 V1.22, Industrial Edge Device Kit - x86-64 V1.23, Industrial Edge Device Kit - x86-64 V1.24, Industrial Edge Device Kit - x86-64 V1.25, Industrial Edge Device Kit - x86-64 V1.26, Industrial Edge Device Kit - x86-64 V1.27, Industrial Edge Device Kit - x86-64 V1.28, Industrial Edge Device Kit - x86-64 V1.5, Industrial Edge Device Kit - x86-64 V1.6, Industrial Edge Device Kit - x86-64 V1.7, Industrial Edge Device Kit - x86-64 V1.8, Industrial Edge Device Kit - x86-64 V1.9, Industrial Edge Own Device (IEOD), Industrial Edge Virtual Device (IEVD), SCALANCE LPE9413 (6GK5998-3GS01-2AC2), SCALANCE LPE9433 (6GK5998-3GS11-2AC2), SIMATIC IoT2050 Advanced IED (6ES7647-0BW00-1YA2), SIMATIC IoT2050 SM IED (6ES7647-0CW00-1AA2), SIMATIC IPC BX-21A Industrial Edge Device, SIMATIC IPC BX-39A Industrial Edge Device, SIMATIC IPC BX-59A Industrial Edge Device, SIMATIC IPC127E Industrial Edge Device, SIMATIC IPC227E Industrial Edge Device, SIMATIC IPC227G Industrial Edge Device, SIMATIC IPC427E Industrial Edge Device, SIMATIC IPC847E Industrial Edge Device. Affected systems do not properly restrict access to internal APIs and paths for authenticated users. This could allow an authenticated remote attacker to access sensitive internal information, which in the worst case could be leveraged to facilitate unauthorized access to the system.

Why it matters now

Exploitation None reported CISA SSVC · not in CISA KEV
EPSS 0.00468 40th percentileScored 2026-11-07
Fix Fixed Industrial Edge Cloud Device (IECD) (Siemens): V1.28.1Industrial Edge Device Kit - arm64 V1.26 (Siemens): V1.26.2-1+17 more products

SSVC decision points

CISA ADP · SSVC 2.0.3

Exploitation
None
Automatable
No
Technical impact
Partial

The decision (Track, Attend, Act) also depends on your mission and well-being impact; see CISA's SSVC guide.

Affected products

VendorProductAffected versionsFixed inStatusSource
SiemensIndustrial Edge Cloud Device (IECD)before V1.28.1V1.28.1Patch availableCNA
SiemensIndustrial Edge Device Kit - arm64 V1.10all versions—No fix listedCNA
SiemensIndustrial Edge Device Kit - arm64 V1.11all versions—No fix listedCNA
SiemensIndustrial Edge Device Kit - arm64 V1.12all versions—No fix listedCNA
SiemensIndustrial Edge Device Kit - arm64 V1.13all versions—No fix listedCNA
SiemensIndustrial Edge Device Kit - arm64 V1.14all versions—No fix listedCNA
SiemensIndustrial Edge Device Kit - arm64 V1.15all versions—No fix listedCNA
SiemensIndustrial Edge Device Kit - arm64 V1.16all versions—No fix listedCNA
SiemensIndustrial Edge Device Kit - arm64 V1.17all versions—No fix listedCNA
SiemensIndustrial Edge Device Kit - arm64 V1.18all versions—No fix listedCNA
SiemensIndustrial Edge Device Kit - arm64 V1.19all versions—No fix listedCNA
SiemensIndustrial Edge Device Kit - arm64 V1.20all versions—No fix listedCNA
SiemensIndustrial Edge Device Kit - arm64 V1.21all versions—No fix listedCNA
SiemensIndustrial Edge Device Kit - arm64 V1.22all versions—No fix listedCNA
SiemensIndustrial Edge Device Kit - arm64 V1.23all versions—No fix listedCNA
SiemensIndustrial Edge Device Kit - arm64 V1.24all versions—No fix listedCNA
SiemensIndustrial Edge Device Kit - arm64 V1.25all versions—No fix listedCNA
SiemensIndustrial Edge Device Kit - arm64 V1.26before V1.26.2-1V1.26.2-1Patch availableCNA
SiemensIndustrial Edge Device Kit - arm64 V1.27before V1.27.1-1V1.27.1-1Patch availableCNA
SiemensIndustrial Edge Device Kit - arm64 V1.28before V1.28.0-6V1.28.0-6Patch availableCNA
SiemensIndustrial Edge Device Kit - arm64 V1.5all versions—No fix listedCNA
SiemensIndustrial Edge Device Kit - arm64 V1.6all versions—No fix listedCNA
SiemensIndustrial Edge Device Kit - arm64 V1.7all versions—No fix listedCNA
SiemensIndustrial Edge Device Kit - arm64 V1.8all versions—No fix listedCNA
SiemensIndustrial Edge Device Kit - arm64 V1.9all versions—No fix listedCNA
SiemensIndustrial Edge Device Kit - x86-64 V1.10all versions—No fix listedCNA
SiemensIndustrial Edge Device Kit - x86-64 V1.11all versions—No fix listedCNA
SiemensIndustrial Edge Device Kit - x86-64 V1.12all versions—No fix listedCNA
SiemensIndustrial Edge Device Kit - x86-64 V1.13all versions—No fix listedCNA
SiemensIndustrial Edge Device Kit - x86-64 V1.14all versions—No fix listedCNA
SiemensIndustrial Edge Device Kit - x86-64 V1.15all versions—No fix listedCNA
SiemensIndustrial Edge Device Kit - x86-64 V1.16all versions—No fix listedCNA
SiemensIndustrial Edge Device Kit - x86-64 V1.17all versions—No fix listedCNA
SiemensIndustrial Edge Device Kit - x86-64 V1.18all versions—No fix listedCNA
SiemensIndustrial Edge Device Kit - x86-64 V1.19all versions—No fix listedCNA
SiemensIndustrial Edge Device Kit - x86-64 V1.20all versions—No fix listedCNA
SiemensIndustrial Edge Device Kit - x86-64 V1.21all versions—No fix listedCNA
SiemensIndustrial Edge Device Kit - x86-64 V1.22all versions—No fix listedCNA
SiemensIndustrial Edge Device Kit - x86-64 V1.23all versions—No fix listedCNA
SiemensIndustrial Edge Device Kit - x86-64 V1.24all versions—No fix listedCNA
SiemensIndustrial Edge Device Kit - x86-64 V1.25all versions—No fix listedCNA
SiemensIndustrial Edge Device Kit - x86-64 V1.26before V1.26.2-1V1.26.2-1Patch availableCNA
SiemensIndustrial Edge Device Kit - x86-64 V1.27before V1.27.1-1V1.27.1-1Patch availableCNA
SiemensIndustrial Edge Device Kit - x86-64 V1.28before V1.28.0-6V1.28.0-6Patch availableCNA
SiemensIndustrial Edge Device Kit - x86-64 V1.5all versions—No fix listedCNA
SiemensIndustrial Edge Device Kit - x86-64 V1.6all versions—No fix listedCNA
SiemensIndustrial Edge Device Kit - x86-64 V1.7all versions—No fix listedCNA
SiemensIndustrial Edge Device Kit - x86-64 V1.8all versions—No fix listedCNA
SiemensIndustrial Edge Device Kit - x86-64 V1.9all versions—No fix listedCNA
SiemensIndustrial Edge Own Device (IEOD)before V1.28.1V1.28.1Patch availableCNA
SiemensIndustrial Edge Virtual Device (IEVD)before V1.28.1V1.28.1Patch availableCNA
SiemensSCALANCE LPE9413all versions—No fix listedCNA
SiemensSCALANCE LPE9433all versions—No fix listedCNA
SiemensSIMATIC IoT2050 Advanced IEDbefore V1.28.1-2V1.28.1-2Patch availableCNA
SiemensSIMATIC IoT2050 SM IEDbefore V1.28.1-2V1.28.1-2Patch availableCNA
SiemensSIMATIC IPC BX-21A Industrial Edge Devicebefore V1.28.1-2V1.28.1-2Patch availableCNA
SiemensSIMATIC IPC BX-39A Industrial Edge Devicebefore V3.2.0-17V3.2.0-17Patch availableCNA
SiemensSIMATIC IPC BX-59A Industrial Edge Devicebefore V3.2.0-17V3.2.0-17Patch availableCNA
SiemensSIMATIC IPC127E Industrial Edge Devicebefore V3.2.0-17V3.2.0-17Patch availableCNA
SiemensSIMATIC IPC227E Industrial Edge Devicebefore V3.2.0-17V3.2.0-17Patch availableCNA
SiemensSIMATIC IPC227G Industrial Edge Devicebefore V3.2.0-17V3.2.0-17Patch availableCNA
SiemensSIMATIC IPC427E Industrial Edge Devicebefore V3.2.0-17V3.2.0-17Patch availableCNA
SiemensSIMATIC IPC847E Industrial Edge Devicebefore V3.2.0-17V3.2.0-17Patch availableCNA
  • Industrial Edge Cloud Device (IECD) VendorSiemens Affected before V1.28.1 Fixed in V1.28.1 Patch available CNA
  • Industrial Edge Device Kit - arm64 V1.10 VendorSiemens Affected all versions Fixed in — No fix listed CNA
  • Industrial Edge Device Kit - arm64 V1.11 VendorSiemens Affected all versions Fixed in — No fix listed CNA
  • Industrial Edge Device Kit - arm64 V1.12 VendorSiemens Affected all versions Fixed in — No fix listed CNA
  • Industrial Edge Device Kit - arm64 V1.13 VendorSiemens Affected all versions Fixed in — No fix listed CNA
  • Industrial Edge Device Kit - arm64 V1.14 VendorSiemens Affected all versions Fixed in — No fix listed CNA
  • Industrial Edge Device Kit - arm64 V1.15 VendorSiemens Affected all versions Fixed in — No fix listed CNA
  • Industrial Edge Device Kit - arm64 V1.16 VendorSiemens Affected all versions Fixed in — No fix listed CNA
  • Industrial Edge Device Kit - arm64 V1.17 VendorSiemens Affected all versions Fixed in — No fix listed CNA
  • Industrial Edge Device Kit - arm64 V1.18 VendorSiemens Affected all versions Fixed in — No fix listed CNA
  • Industrial Edge Device Kit - arm64 V1.19 VendorSiemens Affected all versions Fixed in — No fix listed CNA
  • Industrial Edge Device Kit - arm64 V1.20 VendorSiemens Affected all versions Fixed in — No fix listed CNA
  • Industrial Edge Device Kit - arm64 V1.21 VendorSiemens Affected all versions Fixed in — No fix listed CNA
  • Industrial Edge Device Kit - arm64 V1.22 VendorSiemens Affected all versions Fixed in — No fix listed CNA
  • Industrial Edge Device Kit - arm64 V1.23 VendorSiemens Affected all versions Fixed in — No fix listed CNA
  • Industrial Edge Device Kit - arm64 V1.24 VendorSiemens Affected all versions Fixed in — No fix listed CNA
  • Industrial Edge Device Kit - arm64 V1.25 VendorSiemens Affected all versions Fixed in — No fix listed CNA
  • Industrial Edge Device Kit - arm64 V1.26 VendorSiemens Affected before V1.26.2-1 Fixed in V1.26.2-1 Patch available CNA
  • Industrial Edge Device Kit - arm64 V1.27 VendorSiemens Affected before V1.27.1-1 Fixed in V1.27.1-1 Patch available CNA
  • Industrial Edge Device Kit - arm64 V1.28 VendorSiemens Affected before V1.28.0-6 Fixed in V1.28.0-6 Patch available CNA
  • Industrial Edge Device Kit - arm64 V1.5 VendorSiemens Affected all versions Fixed in — No fix listed CNA
  • Industrial Edge Device Kit - arm64 V1.6 VendorSiemens Affected all versions Fixed in — No fix listed CNA
  • Industrial Edge Device Kit - arm64 V1.7 VendorSiemens Affected all versions Fixed in — No fix listed CNA
  • Industrial Edge Device Kit - arm64 V1.8 VendorSiemens Affected all versions Fixed in — No fix listed CNA
  • Industrial Edge Device Kit - arm64 V1.9 VendorSiemens Affected all versions Fixed in — No fix listed CNA
  • Industrial Edge Device Kit - x86-64 V1.10 VendorSiemens Affected all versions Fixed in — No fix listed CNA
  • Industrial Edge Device Kit - x86-64 V1.11 VendorSiemens Affected all versions Fixed in — No fix listed CNA
  • Industrial Edge Device Kit - x86-64 V1.12 VendorSiemens Affected all versions Fixed in — No fix listed CNA
  • Industrial Edge Device Kit - x86-64 V1.13 VendorSiemens Affected all versions Fixed in — No fix listed CNA
  • Industrial Edge Device Kit - x86-64 V1.14 VendorSiemens Affected all versions Fixed in — No fix listed CNA
  • Industrial Edge Device Kit - x86-64 V1.15 VendorSiemens Affected all versions Fixed in — No fix listed CNA
  • Industrial Edge Device Kit - x86-64 V1.16 VendorSiemens Affected all versions Fixed in — No fix listed CNA
  • Industrial Edge Device Kit - x86-64 V1.17 VendorSiemens Affected all versions Fixed in — No fix listed CNA
  • Industrial Edge Device Kit - x86-64 V1.18 VendorSiemens Affected all versions Fixed in — No fix listed CNA
  • Industrial Edge Device Kit - x86-64 V1.19 VendorSiemens Affected all versions Fixed in — No fix listed CNA
  • Industrial Edge Device Kit - x86-64 V1.20 VendorSiemens Affected all versions Fixed in — No fix listed CNA
  • Industrial Edge Device Kit - x86-64 V1.21 VendorSiemens Affected all versions Fixed in — No fix listed CNA
  • Industrial Edge Device Kit - x86-64 V1.22 VendorSiemens Affected all versions Fixed in — No fix listed CNA
  • Industrial Edge Device Kit - x86-64 V1.23 VendorSiemens Affected all versions Fixed in — No fix listed CNA
  • Industrial Edge Device Kit - x86-64 V1.24 VendorSiemens Affected all versions Fixed in — No fix listed CNA
  • Industrial Edge Device Kit - x86-64 V1.25 VendorSiemens Affected all versions Fixed in — No fix listed CNA
  • Industrial Edge Device Kit - x86-64 V1.26 VendorSiemens Affected before V1.26.2-1 Fixed in V1.26.2-1 Patch available CNA
  • Industrial Edge Device Kit - x86-64 V1.27 VendorSiemens Affected before V1.27.1-1 Fixed in V1.27.1-1 Patch available CNA
  • Industrial Edge Device Kit - x86-64 V1.28 VendorSiemens Affected before V1.28.0-6 Fixed in V1.28.0-6 Patch available CNA
  • Industrial Edge Device Kit - x86-64 V1.5 VendorSiemens Affected all versions Fixed in — No fix listed CNA
  • Industrial Edge Device Kit - x86-64 V1.6 VendorSiemens Affected all versions Fixed in — No fix listed CNA
  • Industrial Edge Device Kit - x86-64 V1.7 VendorSiemens Affected all versions Fixed in — No fix listed CNA
  • Industrial Edge Device Kit - x86-64 V1.8 VendorSiemens Affected all versions Fixed in — No fix listed CNA
  • Industrial Edge Device Kit - x86-64 V1.9 VendorSiemens Affected all versions Fixed in — No fix listed CNA
  • Industrial Edge Own Device (IEOD) VendorSiemens Affected before V1.28.1 Fixed in V1.28.1 Patch available CNA
  • Industrial Edge Virtual Device (IEVD) VendorSiemens Affected before V1.28.1 Fixed in V1.28.1 Patch available CNA
  • SCALANCE LPE9413 VendorSiemens Affected all versions Fixed in — No fix listed CNA
  • SCALANCE LPE9433 VendorSiemens Affected all versions Fixed in — No fix listed CNA
  • SIMATIC IoT2050 Advanced IED VendorSiemens Affected before V1.28.1-2 Fixed in V1.28.1-2 Patch available CNA
  • SIMATIC IoT2050 SM IED VendorSiemens Affected before V1.28.1-2 Fixed in V1.28.1-2 Patch available CNA
  • SIMATIC IPC BX-21A Industrial Edge Device VendorSiemens Affected before V1.28.1-2 Fixed in V1.28.1-2 Patch available CNA
  • SIMATIC IPC BX-39A Industrial Edge Device VendorSiemens Affected before V3.2.0-17 Fixed in V3.2.0-17 Patch available CNA
  • SIMATIC IPC BX-59A Industrial Edge Device VendorSiemens Affected before V3.2.0-17 Fixed in V3.2.0-17 Patch available CNA
  • SIMATIC IPC127E Industrial Edge Device VendorSiemens Affected before V3.2.0-17 Fixed in V3.2.0-17 Patch available CNA
  • SIMATIC IPC227E Industrial Edge Device VendorSiemens Affected before V3.2.0-17 Fixed in V3.2.0-17 Patch available CNA
  • SIMATIC IPC227G Industrial Edge Device VendorSiemens Affected before V3.2.0-17 Fixed in V3.2.0-17 Patch available CNA
  • SIMATIC IPC427E Industrial Edge Device VendorSiemens Affected before V3.2.0-17 Fixed in V3.2.0-17 Patch available CNA
  • SIMATIC IPC847E Industrial Edge Device VendorSiemens Affected before V3.2.0-17 Fixed in V3.2.0-17 Patch available CNA

Remediation

Upgrade Industrial Edge Cloud Device (IECD) to V1.28.1, which is the fixed version. The sources list no fixed version for Industrial Edge Device Kit - arm64 V1.10 or for the other affected products.

Written with Claude Haiku 5.5 from the sources below · 2026-10-27

  • Fix · CNA Industrial Edge Cloud Device (IECD) (Siemens) Fixed in V1.28.1
  • Fix · CNA Industrial Edge Device Kit - arm64 V1.26 (Siemens) Fixed in V1.26.2-1
  • Fix · CNA Industrial Edge Device Kit - arm64 V1.27 (Siemens) Fixed in V1.27.1-1
  • Fix · CNA Industrial Edge Device Kit - arm64 V1.28 (Siemens) Fixed in V1.28.0-6
  • Fix · CNA Industrial Edge Device Kit - x86-64 V1.26 (Siemens) Fixed in V1.26.2-1
  • Fix · CNA Industrial Edge Device Kit - x86-64 V1.27 (Siemens) Fixed in V1.27.1-1
  • Fix · CNA Industrial Edge Device Kit - x86-64 V1.28 (Siemens) Fixed in V1.28.0-6
  • Fix · CNA Industrial Edge Own Device (IEOD) (Siemens) Fixed in V1.28.1
  • Fix · CNA Industrial Edge Virtual Device (IEVD) (Siemens) Fixed in V1.28.1
  • Fix · CNA SIMATIC IoT2050 Advanced IED (Siemens) Fixed in V1.28.1-2
  • Fix · CNA SIMATIC IoT2050 SM IED (Siemens) Fixed in V1.28.1-2
  • Fix · CNA SIMATIC IPC BX-21A Industrial Edge Device (Siemens) Fixed in V1.28.1-2
  • Fix · CNA SIMATIC IPC BX-39A Industrial Edge Device (Siemens) Fixed in V3.2.0-17
  • Fix · CNA SIMATIC IPC BX-59A Industrial Edge Device (Siemens) Fixed in V3.2.0-17
  • Fix · CNA SIMATIC IPC127E Industrial Edge Device (Siemens) Fixed in V3.2.0-17
  • Fix · CNA SIMATIC IPC227E Industrial Edge Device (Siemens) Fixed in V3.2.0-17
  • Fix · CNA SIMATIC IPC227G Industrial Edge Device (Siemens) Fixed in V3.2.0-17
  • Fix · CNA SIMATIC IPC427E Industrial Edge Device (Siemens) Fixed in V3.2.0-17
  • Fix · CNA SIMATIC IPC847E Industrial Edge Device (Siemens) Fixed in V3.2.0-17

Fixed in the same release

Records fixed by the same vendor advisory or release, as the CNA lists them.

  • Release ·

    Siemens Industrial Edge Device Kit - arm64 V1.26, Industrial Edge Device Kit - arm64 V1.27 and 4 more products V1.26.2-1, V1.27.1-1, V1.28.0-6

    2 records Highest priority Priority MEDIUM 1 MEDIUM, 1 LOW

    Other records, highest priority first

    • TI-2026-71569 Missing access checks in Siemens Industrial Edge Device Kit arm64Priority MEDIUM 41

Timeline

  1. 2026-10-13 Threatist record created from CVE-2026-44414
  2. 2026-10-13 Alias added: GHSA-9xh9-64gc-w6jh
  3. 2026-10-14 CISA SSVC decision points changed
  4. 2026-10-14 Priority changed: MEDIUM → LOW

References

  • TI-2026-20057 Authentication bypass in Fortinet FortiWeb KEVCVSS 3.1CRITICAL 9.4
  • TI-2025-26358 tls: fix handling of zero-length records on the rx_list KEVCVSS 3.1CRITICAL 9.8
  • TI-2025-18911 Heap-based buffer overflow in Fortinet FortiSwitchManager KEVCVSS 3.1CRITICAL 9.8
  • TI-2025-09686 Type confusion in Google Chrome KEVCVSS 3.1CRITICAL 9.8
  • TI-2022-07142 Code injection in Spring Framework KEVCVSS 3.1CRITICAL 9.8
  • TI-2021-19919 Apache Log4j2 JNDI features do not protect against attacker controlled LDAP and other JNDI related endpoints KEVCVSS 3.1CRITICAL 10.0
See all 2487 →

Sources