Read the docs
TI-2026-71579 Aliases CVE-2026-72895GHSA-f9v9-v28p-r5mp

Test key in UEFI Secure Boot database in Siemens SIMATIC IPC devices

Priority LOW 37CWE-1394Published · Updated

Key facts

Attack vector
Local
Privileges required
None
User interaction
Active
Attack complexity
Low
Attack requirements
None
Impact type
—
Confidentiality · integrity · availability
High · High · High
Fix status
Fixed

Attack profile from CVSS 4.0 · CNA. Fix status from CNA.

Summary

Siemens SIMATIC IPC BX-21A, SIMATIC IPC RW-543A, and SIMATIC IPC227G, IPC277G, IPC277G PRO, IPC327G and IPC377G are affected in versions before V31.01.13, V1.1.4 and V28.01.15 respectively. The UEFI Secure Boot key database contains a BIOS vendor test key, which is a use of default cryptographic key (CWE-1394). A local attacker with physical or administrative access can boot an operating system or UEFI application signed with that test key, bypassing Secure Boot even when it is enabled.

Written with Claude Haiku 5.5 from the sources below · 2026-10-27

Description from the CNA

A vulnerability has been identified in SIMATIC IPC BX-21A (All versions < V31.01.13), SIMATIC IPC RW-543A (All versions < V1.1.4), SIMATIC IPC227G / IPC277G / IPC277G PRO / IPC327G / IPC377G (All versions < V28.01.15). A BIOS vendor test key is present in the UEFI Secure Boot key database. This could allow a local attacker with physical or administrative access to the device to boot an operating system or UEFI application signed with that test key, bypassing UEFI Secure Boot protections even when Secure Boot is enabled, potentially leading to a full loss of confidentiality, integrity, and availability of the device.

Why it matters now

Exploitation None reported CISA SSVC · not in CISA KEV
EPSS 0.00107 1st percentileScored 2026-11-07
Fix Fixed SIMATIC IPC BX-21A (Siemens): V31.01.13SIMATIC IPC RW-543A (Siemens): V1.1.4+1 more product

SSVC decision points

CISA ADP · SSVC 2.0.3

Exploitation
None
Automatable
No
Technical impact
Total

The decision (Track, Attend, Act) also depends on your mission and well-being impact; see CISA's SSVC guide.

Affected products

VendorProductAffected versionsFixed inStatusSource
SiemensSIMATIC IPC BX-21Abefore V31.01.13V31.01.13Patch availableCNA
SiemensSIMATIC IPC RW-543Abefore V1.1.4V1.1.4Patch availableCNA
SiemensSIMATIC IPC227G / IPC277G / IPC277G PRO / IPC327G / IPC377Gbefore V28.01.15V28.01.15Patch availableCNA
  • SIMATIC IPC BX-21A VendorSiemens Affected before V31.01.13 Fixed in V31.01.13 Patch available CNA
  • SIMATIC IPC RW-543A VendorSiemens Affected before V1.1.4 Fixed in V1.1.4 Patch available CNA
  • SIMATIC IPC227G / IPC277G / IPC277G PRO / IPC327G / IPC377G VendorSiemens Affected before V28.01.15 Fixed in V28.01.15 Patch available CNA

Remediation

Siemens lists fixed versions V31.01.13 for SIMATIC IPC BX-21A, V1.1.4 for SIMATIC IPC RW-543A, and V28.01.15 for SIMATIC IPC227G, IPC277G, IPC277G PRO, IPC327G and IPC377G.

Written with Claude Haiku 5.5 from the sources below · 2026-10-27

  • Fix · CNA SIMATIC IPC BX-21A (Siemens) Fixed in V31.01.13
  • Fix · CNA SIMATIC IPC RW-543A (Siemens) Fixed in V1.1.4
  • Fix · CNA SIMATIC IPC227G / IPC277G / IPC277G PRO / IPC327G / IPC377G (Siemens) Fixed in V28.01.15

Timeline

  1. 2026-10-13 Threatist record created from CVE-2026-72895
  2. 2026-10-13 Alias added: GHSA-f9v9-v28p-r5mp
  3. 2026-10-14 Priority changed: MEDIUM → LOW
  4. 2026-10-15 CISA SSVC decision points changed

References

  • TI-2026-20057 Authentication bypass in Fortinet FortiWeb KEVCVSS 3.1CRITICAL 9.4
  • TI-2025-26358 tls: fix handling of zero-length records on the rx_list KEVCVSS 3.1CRITICAL 9.8
  • TI-2025-18911 Heap-based buffer overflow in Fortinet FortiSwitchManager KEVCVSS 3.1CRITICAL 9.8
  • TI-2025-09686 Type confusion in Google Chrome KEVCVSS 3.1CRITICAL 9.8
  • TI-2022-07142 Code injection in Spring Framework KEVCVSS 3.1CRITICAL 9.8
  • TI-2021-19919 Apache Log4j2 JNDI features do not protect against attacker controlled LDAP and other JNDI related endpoints KEVCVSS 3.1CRITICAL 10.0
See all 2487 →

Sources