Access restriction bypass in Hitachi Energy TRO600 firmware
Key facts
- Attack vector
- Network
- Privileges required
- Low
- User interaction
- None
- Attack complexity
- High
- Attack requirements
- Present
- Impact type
- —
- Confidentiality · integrity · availability
- High · High · High
- Fix status
- No fix listed
Attack profile from CVSS 4.0 · CNA. Fix status from CNA.
Summary
Hitachi Energy TRO600 Series Firmware from 9.0.0.0 through 9.2.1.6 has an improper restriction of communication channel to intended endpoints (CWE-923). An authenticated remote attacker with low privileges can bypass network access restrictions and reach services meant to be reachable only from localhost. This exposes sensitive functionality and confidential information and can affect availability.
Written with Claude Haiku 5.5 from the sources below · 2026-11-04
Description from the CNA
TRO600 contains a vulnerability that allows an authenticated attacker to bypass network access restrictions and access services intended to be reachable only from localhost. By leveraging port forwarding, an attacker can interact with locally bound ports and services, resulting in unauthorized access to sensitive functionality and confidential information, and causing availability impact.
Why it matters now
SSVC decision points
CISA ADP · SSVC 2.0.3
- Exploitation
- None
- Automatable
- No
- Technical impact
- Total
The decision (Track, Attend, Act) also depends on your mission and well-being impact; see CISA's SSVC guide.
Affected products
| Vendor | Product | Affected versions | Fixed in | Status | Source |
|---|---|---|---|---|---|
| Hitachi Energy | TRO600 Series Firmware | 9.0.0.0 – 9.2.1.6 | — | No fix listed | CNA |
- TRO600 Series Firmware VendorHitachi Energy Affected 9.0.0.0 – 9.2.1.6 Fixed in — No fix listed CNA
Remediation
The sources list no fixed version for Hitachi Energy TRO600 Series Firmware.
Written with Claude Haiku 5.5 from the sources below · 2026-11-04
Timeline
- 2026-10-27 Threatist record created from CVE-2026-10756
- 2026-10-27 Alias added: GHSA-h7g2-j4fw-5qp6
- 2026-10-28 Priority changed: MEDIUM → LOW
- 2026-11-04 CISA SSVC decision points changed
References
More Hitachi Energy vulnerabilities
- TI-2019-03985 ABB MicroSCADA Pro SYS600 Missing Authentication for Critical Function CVSS 3.1CRITICAL 9.8
- TI-2018-10635 Improper authentication in ICS-CERT ABB eSOMS CVSS 3.0CRITICAL 9.8
- TI-2024-01871 Heap-based buffer overflow in Hitachi Energy FOXMAN-UN CVSS 3.1CRITICAL 9.8
- TI-2026-07105 Path traversal in Hitachi Energy RTU500 series CMU firmware CVSS 3.1CRITICAL 9.1
- TI-2019-13270 Path traversal in Relion 670 Series CVSS 3.1CRITICAL 10.0
- TI-2026-07104 Missing authentication in Hitachi Energy RTU500 series CMU firmware CVSS 3.1CRITICAL 9.1
Sources
- CVE-2026-10756 · CVE Program
- CVE-2026-10756 · NVD
- FIRST EPSS
- GHSA-h7g2-j4fw-5qp6 · GitHub Advisory Database · CC BY 4.0
This product uses the NVD API but is not endorsed or certified by the NVD. Sources and licences