Read the docs
TI-2026-86150 Aliases CVE-2026-59104GHSA-8f29-c49m-pq4g

Authentication bypass in UgCS server HCI login handler

Priority MEDIUM 41CWE-287Published · Updated

Key facts

Attack vector
Network
Privileges required
None
User interaction
None
Attack complexity
Low
Attack requirements
None
Impact type
Security bypass
Confidentiality · integrity · availability
High · High · High
Fix status
Fixed

Attack profile from CVSS 4.0 · CNA. Fix status from CNA. Impact type from CWE-287.

Summary

SPH Engineering UgCS server before 6.2 contains an authentication bypass in the HCI protocol login handler on TCP port 3334. When the user database holds exactly one user, a login request with empty credentials is treated as a login for that user, and the server returns an authenticated session. An unauthenticated remote attacker with network access to the port can obtain a session without any credential and then issue privileged commands, including commanding connected drones and uploading flight routes. The flaw is classified as CWE-287.

Written with Claude Haiku 5.5 from the sources below · 2026-11-07

Description from the CNA

UgCS server before 6.2 contains an authentication bypass in the HCI protocol login handler (LoginHandler) exposed on TCP port 3334. When the user database contains exactly one user (the default single-operator installation), a LoginRequest with empty userLogin and userPassword fields is interpreted as \"use the only user\" rather than as invalid credentials, and the server returns a fully authenticated session. Because the service listens on all interfaces (0.0.0.0) without TLS by default, an unauthenticated remote attacker with network access to port 3334 can obtain an authenticated session without knowing any credential and then issue privileged commands, including commanding connected drones and uploading flight routes.

Why it matters now

EPSS 0.00659 51st percentileScored 2026-11-07
Fix Fixed UgCS (SPH Engineering): 6.2

SSVC decision points

Not available: CISA has not published SSVC decision points for this record.

Affected products

VendorProductAffected versionsFixed inStatusSource
SPH EngineeringUgCSbefore 6.26.2Patch availableCNA
  • UgCS VendorSPH Engineering Affected before 6.2 Fixed in 6.2 Patch available CNA

Remediation

Update SPH Engineering UgCS to version 6.2 or later, which is the fixed version.

Written with Claude Haiku 5.5 from the sources below · 2026-11-07

  • Fix · CNA UgCS (SPH Engineering) Fixed in 6.2

Timeline

  1. 2026-11-06 Threatist record created from CVE-2026-59104
  2. 2026-11-07 Alias added: GHSA-8f29-c49m-pq4g

References

Sources