Mass assignment in NervesHub lets users write into other organizations
Key facts
- Attack vector
- Network
- Privileges required
- Low
- User interaction
- None
- Attack complexity
- Low
- Attack requirements
- None
- Impact type
- Security bypass, Tampering
- Confidentiality · integrity · availability
- High · High · None
- Fix status
- Fixed
Attack profile from CVSS 4.0 · CNA. Fix status from CNA. Impact type from CWE-639 and CWE-915.
Summary
NervesHub nerves_hub_web from 1.0.0 before 2.5.3 does not restrict the organization, product and deployment group IDs that users submit in device, signing key, product and JITP requests. An authenticated user who manages devices in any organization can write into other organizations by submitting org_id, product_id and deployment_id fields (CWE-915). A device moved into another organization's deployment group receives that organization's firmware and its download URL.
Written with Claude Haiku 5.5 from the sources below · 2026-11-12
Description from the CNA
Improperly Controlled Modification of Dynamically-Determined Object Attributes vulnerability in the device API, device forms, signing key and product forms and JITP settings in nerves-hub nerves_hub_web allows an authenticated user who manages devices in any organization to write into other organizations via submitted org_id, product_id and deployment_id fields. The device API create and update actions and the dashboard device forms pass the request parameters to NervesHub.Devices.Device.changeset/2, which casts the organization, product, deployment group and update state as given. The signing key and product forms merge the session's organization into the submitted parameters so that a submitted org_id wins, and the JITP changeset accepts any product_id. Each request requires the manage role only in the user's own organization, and any account can create one. A device placed on another organization's deployment group, or moved into its product, is sent that organization's firmware with a download URL. The user cannot change or control devices that already belong to the other organization, and cannot upload firmware to it. This issue affects nerves_hub: from 1.0.0 before 2.5.3.
Why it matters now
SSVC decision points
CISA ADP · SSVC 2.0.3
- Exploitation
- Poc
- Automatable
- No
- Technical impact
- Total
The decision (Track, Attend, Act) also depends on your mission and well-being impact; see CISA's SSVC guide.
Affected products
| Vendor | Product | Affected versions | Fixed in | Status | Source |
|---|---|---|---|---|---|
| nerves-hub | nerves_hub_web | 1.0.0 to before 2.5.3 | 2.5.3 | Patch available | CNA |
| nerves-hub | nerves_hub_web | 1.0.0 to before 2.5.3 | 2.5.3 | Patch available | CNA |
- nerves_hub_web Vendornerves-hub Affected 1.0.0 to before 2.5.3 Fixed in 2.5.3 Patch available CNA
- nerves_hub_web Vendornerves-hub Affected 1.0.0 to before 2.5.3 Fixed in 2.5.3 Patch available CNA
CPE names CNA · 1
| CPE | Versions | Role | Vendor |
|---|---|---|---|
| cpe:2.3:a:nerves-hub:nerves_hub_web:*:*:*:*:*:*:*:* | — | — | nerves-hub |
- cpe:2.3:a:nerves-hub:nerves_hub_web:*:*:*:*:*:*:*:* Versions — — ·nerves-hub
Remediation
Update nerves_hub_web to 2.5.3, the fixed version.
Written with Claude Haiku 5.5 from the sources below · 2026-11-12
- Fix · CNA nerves_hub_web (nerves-hub) Fixed in 2.5.3
- Fix · CNA nerves_hub_web (nerves-hub) Fixed in 2.5.3
Fixed in the same release
Records fixed by the same vendor advisory or release, as the CNA lists them.
- Release ·
nerves-hub nerves_hub_web 2.5.3
6 records Highest priority Priority HIGH 3 HIGH, 3 MEDIUM
Other records, highest priority first
- TI-2026-87598 Session fixation in NervesHub CLI login exposes user API tokensPriority HIGH 76
- TI-2026-87603 Improper authentication in NervesHub Web exposes accounts via emailPriority HIGH 68
- TI-2026-87600 Incorrect authorization in NervesHub Web lets view users move devicesPriority MEDIUM 64
Timeline
- 2026-11-10 Threatist record created from CVE-2026-120730
- 2026-11-11 Fix available: [email protected] · CNA
- 2026-11-11 Fix available: nerves-hub/[email protected] · CNA
- 2026-11-12 Priority changed: MEDIUM → LOW
- 2026-11-12 CISA SSVC decision points changed
References
More nerves-hub vulnerabilities
- TI-2026-87598 Session fixation in NervesHub CLI login exposes user API tokens CVSS 4.0CRITICAL 9.4
- TI-2026-87603 Improper authentication in NervesHub Web exposes accounts via email CVSS 4.0HIGH 7.4
- TI-2026-87600 Incorrect authorization in NervesHub Web lets view users move devices CVSS 4.0HIGH 7.1
- TI-2026-87599 Missing authorization in nerves_hub_web lets viewers change devices CVSS 4.0MEDIUM 5.3
- TI-2025-39548 NervesHub has Insufficient Token Entropy that Allows Authentication Bypass via Brute Force CVSS 4.0CRITICAL 9.5
- TI-2026-87602 Removed or demoted nerves_hub_web members keep their old role CVSS 4.0LOW 2.3
Sources
This product uses the NVD API but is not endorsed or certified by the NVD. Sources and licences