Read the docs

Siemens SIMATIC WinCC runs active content when files are opened

Priority LOW 38CWE-357Published · Updated

Key facts

Attack vector
Local
Privileges required
None
User interaction
Passive
Attack complexity
Low
Attack requirements
None
Impact type
—
Confidentiality · integrity · availability
High · High · High
Fix status
No fix listed

Attack profile from CVSS 4.0 · CNA. Fix status from CNA.

Summary

Siemens SIMATIC WinCC V7.5, V8.0 and V8.1 are affected in all versions. Affected devices implicitly execute active content when opening files, a flaw classified as CWE-357 (insufficient UI warning of dangerous operations). An attacker can make a user execute arbitrary code on the device by getting the user to open a file, which the CVSS vector rates as high impact to confidentiality, integrity and availability.

Written with Claude Haiku 5.5 from the sources below · 2026-11-10

Description from the CNA

A vulnerability has been identified in SIMATIC WinCC V7.5 (All versions), SIMATIC WinCC V8.0 (All versions), SIMATIC WinCC V8.1 (All versions). Affected devices implicitly execute active content when opening files. This could allow an attacker to make the user execute arbitrary code on the device.

Why it matters now

Exploitation None reported CISA SSVC · not in CISA KEV
EPSS 0.00126 2nd percentileScored 2026-11-16
Fix No fix listed No fixed version in the sources yet

SSVC decision points

CISA ADP · SSVC 2.0.3

Exploitation
None
Automatable
No
Technical impact
Total

The decision (Track, Attend, Act) also depends on your mission and well-being impact; see CISA's SSVC guide.

Affected products

VendorProductAffected versionsFixed inStatusSource
SiemensSIMATIC WinCC V7.5all versions—No fix listedCNA
SiemensSIMATIC WinCC V8.0all versions—No fix listedCNA
SiemensSIMATIC WinCC V8.1all versions—No fix listedCNA
  • SIMATIC WinCC V7.5 VendorSiemens Affected all versions Fixed in — No fix listed CNA
  • SIMATIC WinCC V8.0 VendorSiemens Affected all versions Fixed in — No fix listed CNA
  • SIMATIC WinCC V8.1 VendorSiemens Affected all versions Fixed in — No fix listed CNA

Remediation

The sources list no fixed version for SIMATIC WinCC V7.5. The sources list no fixed version for SIMATIC WinCC V8.0. The sources list no fixed version for SIMATIC WinCC V8.1.

Written with Claude Haiku 5.5 from the sources below · 2026-11-10

Timeline

  1. 2026-11-10 Threatist record created from CVE-2026-59082
  2. 2026-11-10 Alias added: GHSA-q5qg-vg83-p5q8
  3. 2026-11-12 Priority changed: MEDIUM → LOW
  4. 2026-11-13 CISA SSVC decision points changed

References

  • TI-2026-20057 Authentication bypass in Fortinet FortiOS and other products KEVCVSS 3.1CRITICAL 9.4
  • TI-2025-26358 Zero-length TLS records mishandled on rx_list in Linux kernel KEVCVSS 3.1CRITICAL 9.8
  • TI-2025-18911 Heap-based buffer overflow in Fortinet FortiOS and FortiSwitchManager KEVCVSS 3.1CRITICAL 9.8
  • TI-2025-09686 Type confusion in V8 in Google Chrome allows heap corruption KEVCVSS 3.1CRITICAL 9.8
  • TI-2022-07142 Spring Framework data binding flaw allows remote code execution on JDK 9+ KEVCVSS 3.1CRITICAL 9.8
  • TI-2021-19919 Apache Log4j2 JNDI features let attackers load code from LDAP servers KEVCVSS 3.1CRITICAL 10.0
See all 2500 →

Sources