Read the docs

Unrestricted network binding in Siemens Mendix Studio Pro MCP Server

Priority MEDIUM 41CWE-1327Published · Updated

Key facts

Attack vector
Network
Privileges required
None
User interaction
None
Attack complexity
Low
Attack requirements
Present
Impact type
—
Confidentiality · integrity · availability
High · High · High
Fix status
Fixed

Attack profile from CVSS 4.0 · CNA. Fix status from CNA.

Summary

Siemens Mendix Studio Pro 11 from V11.15.0 before V11.16.0 and Mendix Studio Pro 11.12 from V11.12.6 before V11.12.7 are affected. The MCP Server does not restrict its HTTP listener to the loopback interface (CWE-1327), so it can be reachable from remote systems. An attacker with network access and no privileges can interact with the MCP Server remotely.

Written with Claude Haiku 5.5 from the sources below · 2026-11-10

Description from the CNA

A vulnerability has been identified in Mendix Studio Pro 11 (All versions >= V11.15.0 < V11.16.0), Mendix Studio Pro 11.12 (All versions >= V11.12.6 < V11.12.7). The affected products MCP Server does not properly restrict its HTTP listener to the loopback interface, leaving it potentially exposed to remote systems. This could allow an attacker with network access to interact with the MCP Server remotely.

Why it matters now

Exploitation None reported CISA SSVC · not in CISA KEV
EPSS 0.00304 23rd percentileScored 2026-11-16
Fix Fixed Mendix Studio Pro 11 (Siemens): V11.16.0Mendix Studio Pro 11.12 (Siemens): V11.12.7

SSVC decision points

CISA ADP · SSVC 2.0.3

Exploitation
None
Automatable
No
Technical impact
Total

The decision (Track, Attend, Act) also depends on your mission and well-being impact; see CISA's SSVC guide.

Affected products

VendorProductAffected versionsFixed inStatusSource
SiemensMendix Studio Pro 11V11.15.0 to before V11.16.0V11.16.0Patch availableCNA
SiemensMendix Studio Pro 11.12V11.12.6 to before V11.12.7V11.12.7Patch availableCNA
  • Mendix Studio Pro 11 VendorSiemens Affected V11.15.0 to before V11.16.0 Fixed in V11.16.0 Patch available CNA
  • Mendix Studio Pro 11.12 VendorSiemens Affected V11.12.6 to before V11.12.7 Fixed in V11.12.7 Patch available CNA

Remediation

Update Mendix Studio Pro 11 to V11.16.0 and Mendix Studio Pro 11.12 to V11.12.7.

Written with Claude Haiku 5.5 from the sources below · 2026-11-10

  • Fix · CNA Mendix Studio Pro 11 (Siemens) Fixed in V11.16.0
  • Fix · CNA Mendix Studio Pro 11.12 (Siemens) Fixed in V11.12.7

Fixed in the same release

Records fixed by the same vendor advisory or release, as the CNA lists them.

  • Release ·

    Siemens Mendix Studio Pro 11, Mendix Studio Pro 11.12 V11.12.7, V11.16.0

    2 records Highest priority Priority MEDIUM 1 MEDIUM, 1 LOW

    Other records, highest priority first

    • TI-2026-87623 Cross-site request forgery in Mendix Studio Pro MCP ServerPriority LOW 22

Timeline

  1. 2026-11-10 Threatist record created from CVE-2026-112136
  2. 2026-11-10 Alias added: GHSA-6m57-vrcv-v9j4
  3. 2026-11-10 CISA SSVC decision points changed
  4. 2026-11-10 Priority changed: MEDIUM → LOW
  5. 2026-11-12 Priority changed: LOW → MEDIUM

References

  • TI-2026-20057 Authentication bypass in Fortinet FortiOS and other products KEVCVSS 3.1CRITICAL 9.4
  • TI-2025-26358 Zero-length TLS records mishandled on rx_list in Linux kernel KEVCVSS 3.1CRITICAL 9.8
  • TI-2025-18911 Heap-based buffer overflow in Fortinet FortiOS and FortiSwitchManager KEVCVSS 3.1CRITICAL 9.8
  • TI-2025-09686 Type confusion in V8 in Google Chrome allows heap corruption KEVCVSS 3.1CRITICAL 9.8
  • TI-2022-07142 Spring Framework data binding flaw allows remote code execution on JDK 9+ KEVCVSS 3.1CRITICAL 9.8
  • TI-2021-19919 Apache Log4j2 JNDI features let attackers load code from LDAP servers KEVCVSS 3.1CRITICAL 10.0
See all 2500 →

Sources