Missing authorization in Extreme Networks Switch Engine JSON-RPC
Key facts
- Attack vector
- Network
- Privileges required
- Low
- User interaction
- None
- Attack complexity
- Low
- Attack requirements
- None
- Impact type
- Security bypass
- Confidentiality · integrity · availability
- High · None · None
- Fix status
- Fixed
Attack profile from CVSS 4.0 · CNA. Fix status from CNA. Impact type from CWE-862.
Summary
Extreme Networks Switch Engine (EXOS) from 32.0.0 before 32.7.4.15-patch1-11, from 33.1.0 before 33.1.100-patch1-9 and from 33.7.0 before 33.7.1-patch1-11 is affected. The JSON-RPC web services interface lacks an authorization check (CWE-862), letting authenticated read-only users run CLI show commands. Attackers gain the device configuration and local password hashes, which can be cracked offline to gain administrative access.
Written with Claude Haiku 5.5 from the sources below · 2026-11-11
Description from the CNA
Missing authorization in the JSON-RPC web services interface of Extreme Networks Switch Engine (EXOS) allows an authenticated, low-privileged (read-only) user to execute CLI show commands that are restricted to that role through the command line interface. Successful exploitation results in disclosure of sensitive information, including the device configuration and the password hashes of local accounts. Configuration, enable, and debug commands are not affected. Disclosed password hashes can be attacked offline, and a weak password could lead to administrative access to the device. This issue is fixed in Switch Engine 33.7.1-patch1-11, 33.1.100.133-patch1-9, and 32.7.4.15-patch1-11. Extreme Networks would like to thank Toàn Lê (GitHub: https://github.com/toanln-cov) for responsibly disclosing this vulnerability and for working with our PSIRT team through coordinated disclosure.
Why it matters now
SSVC decision points
Not available: CISA has not published SSVC decision points for this record.
Affected products
| Vendor | Product | Affected versions | Fixed in | Status | Source |
|---|---|---|---|---|---|
| Extreme Networks | Switch Engine (EXOS) | 33.7.0 to before 33.7.1-patch1-11; 33.1.0 to before 33.1.100-patch1-9; 32.0.0 to before 32.7.4.15-patch1-11 | 33.7.1-patch1-11, 33.1.100-patch1-9, 32.7.4.15-patch1-11 | Patch available | CNA |
- Switch Engine (EXOS) VendorExtreme Networks Affected 33.7.0 to before 33.7.1-patch1-11; 33.1.0 to before 33.1.100-patch1-9; 32.0.0 to before 32.7.4.15-patch1-11 Fixed in 33.7.1-patch1-11, 33.1.100-patch1-9, 32.7.4.15-patch1-11 Patch available CNA
Remediation
Upgrade to Switch Engine 33.7.1-patch1-11, 33.1.100-patch1-9 or 32.7.4.15-patch1-11, the fixed versions.
Written with Claude Haiku 5.5 from the sources below · 2026-11-11
- Fix · CNA Switch Engine (EXOS) (Extreme Networks) Fixed in 33.7.1-patch1-11, 33.1.100-patch1-9, 32.7.4.15-patch1-11
Timeline
- 2026-11-11 Threatist record created from CVE-2026-105440
- 2026-11-11 Alias added: GHSA-fx77-wm35-pp29
References
More Extreme Networks vulnerabilities
- TI-2020-19042 Extreme Networks Aerohive HiveOS <=11.x 11.x Unauthenticated Remote Denial of Service CVSS 4.0HIGH 8.7
- TI-2020-13364 Extreme Networks EXOS before v.22.7 and before v.30.2 was discovered to contain an issue… CVSS 3.1HIGH 8.0
- TI-2020-12704 The NetConfig UI administrative interface in Extreme Networks ExtremeWireless Aerohive… CVSS 3.1CRITICAL 9.8
- TI-2023-17891 IQ Engine before 10.6r2 on Extreme Network AP devices has a Buffer Overflow. CVSS 3.1CRITICAL 9.8
- TI-2023-17890 IQ Engine before 10.6r1 on Extreme Network AP devices has a Buffer Overflow in the… CVSS 3.1CRITICAL 9.8
- TI-2024-25570 In Extreme Networks XIQ-SE before 24.2.11, due to a missing access control check, a path… CVSS 3.1CRITICAL 9.8
Sources
- CVE-2026-105440 · CVE Program
- CVE-2026-105440 · NVD
- FIRST EPSS
- GHSA-fx77-wm35-pp29 · GitHub Advisory Database · CC BY 4.0
This product uses the NVD API but is not endorsed or certified by the NVD. Sources and licences