Argument injection in Philips Hue Bridge Pro enables file writes
Key facts
- Attack vector
- Local
- Privileges required
- Low
- User interaction
- None
- Attack complexity
- Low
- Impact type
- Code execution
- Confidentiality · integrity · availability
- None · Low · None
- Fix status
- No fix listed
Attack profile from CVSS 3.0 · CNA. Fix status from CNA. Impact type from CWE-88.
Summary
Philips Hue Bridge Pro contains an argument injection flaw in its factory data service, where improper neutralization of argument delimiters in a command (CWE-88) lets input reach a system call unchecked. A local attacker who can run low-privileged code in a container on the target system can modify files with the privileges of the service account. The affected version is 2071026000.
Written with Claude Haiku 5.5 from the sources below · 2026-11-12
Description from the CNA
Philips Hue Bridge Pro Argument Injection Restricted File Write Vulnerability. This vulnerability allows local attackers to modify files on affected installations of Philips Hue Bridge Pro. An attacker must first obtain the ability to execute low-privileged code within a container on the target system, in order to exploit this vulnerability. The specific flaw exists within the factory data service, which listens on TCP port 5001 by default. The issue results from the lack of proper validation of a user-supplied string before using it to execute a system call. An attacker can leverage this vulnerability to modify files in the context of the service account. Was ZDI-CAN-33090.
Why it matters now
SSVC decision points
CISA ADP · SSVC 2.0.3
- Exploitation
- None
- Automatable
- No
- Technical impact
- Total
The decision (Track, Attend, Act) also depends on your mission and well-being impact; see CISA's SSVC guide.
Affected products
Remediation
The sources list no fixed version for Philips Hue Bridge Pro.
Written with Claude Haiku 5.5 from the sources below · 2026-11-12
Timeline
- 2026-11-12 Threatist record created from CVE-2026-118631
- 2026-11-12 Alias added: GHSA-j948-xpmv-47c9
- 2026-11-16 CISA SSVC decision points changed
References
Other 1
More Philips vulnerabilities
- TI-2017-00134 Remote code execution in Microsoft Windows SMBv1 server KEVCVSS 3.1HIGH 8.8
- TI-2017-00184 Remote code execution in Microsoft Office and WordPad KEVCVSS 3.1HIGH 7.8
- TI-2018-06405 Philips EncoreAnywhere Exposure of Sensitive Information to an Unauthorized Actor CVSS 3.1HIGH 7.5
- TI-2018-03984 Improper input validation in Philips IntelliSpace Portal CVSS 3.0CRITICAL 9.8
- TI-2018-06392 Improper input validation in Philips e-Alert Unit CVSS 3.0CRITICAL 9.8
- TI-2018-03982 Access control flaw in Philips IntelliSpace Portal CVSS 3.0CRITICAL 9.8
Sources
- CVE-2026-118631 · CVE Program
- CVE-2026-118631 · NVD
- FIRST EPSS
- GHSA-j948-xpmv-47c9 · GitHub Advisory Database · CC BY 4.0
This product uses the NVD API but is not endorsed or certified by the NVD. Sources and licences