Stored cross-site scripting in Microchip TimePictra
Key facts
- Attack vector
- Network
- Privileges required
- Low
- User interaction
- Passive
- Attack complexity
- Low
- Attack requirements
- None
- Impact type
- Cross-site scripting
- Confidentiality · integrity · availability
- High · High · High
- Fix status
- Fixed
Attack profile from CVSS 4.0 · CNA. Fix status from CNA. Impact type from CWE-79.
Summary
A stored cross-site scripting flaw in Microchip TimePictra (CWE-79) lets an authenticated attacker with low privileges save malicious script that runs when another user views the affected page. The attacker needs a valid low-privilege account and the victim must view the page, and the impact reaches the victim's session in the browser.
Written with Claude Haiku 5.5 from the sources below · 2026-11-12
Description from the CNA
A stored cross-site scripting vulnerability in Microchip the TimePictra platform could allow an authenticated, low-privileged attacker to store malicious script content that executes when another user views the affected page
Why it matters now
SSVC decision points
Not available: CISA has not published SSVC decision points for this record.
Affected products
Remediation
Upgrade Microchip TimePictra to version 12.0 or later. The sources list no advisory identifier for this fix.
Written with Claude Haiku 5.5 from the sources below · 2026-11-12
- Fix · CNA TimePictra (Microchip) Fixed in 12.0
Fixed in the same release
Records fixed by the same vendor advisory or release, as the CNA lists them.
- Release ·
Microchip TimePictra 12.0
3 records Highest priority Priority MEDIUM 2 MEDIUM, 1 LOW
Other records, highest priority first
- TI-2026-90268 Unrestricted file upload in Microchip TimePictra allows remote code executionPriority MEDIUM 41
- TI-2026-90269 Hard-coded root password in Microchip TimePictra installation filesPriority LOW 38
Timeline
- 2026-11-12 Threatist record created from CVE-2026-8333
- 2026-11-12 Alias added: GHSA-2hfc-fw5x-vjm9
References
More Microchip vulnerabilities
- TI-2022-18950 Microchip Technology (Microsemi) SyncServer S650 was discovered to contain a command injection vulnerability. CVSS 3.1CRITICAL 9.8
- TI-2023-28092 Improper input validation in Siemens SIMATIC IPC1047E CVSS 3.1CRITICAL 10.0
- TI-2024-19958 Microchip Harmony 3 Core library allows read and write access to RAM via a SCSI READ or WRITE command CVSS 4.0HIGH 7.0
- TI-2024-08405 Remote code Execution inTimeProvider® 4100 CVSS 4.0HIGH 8.5
- TI-2009-01524 Multiple buffer overflows in Microchip MPLAB IDE 8.30 and possibly earlier versions allow… CVSS 2.0HIGH 9.3
- TI-2020-13207 An issue was discovered in picoTCP 1.7.0. CVSS 3.1CRITICAL 9.1
Sources
- CVE-2026-8333 · CVE Program
- CVE-2026-8333 · NVD
- FIRST EPSS
- GHSA-2hfc-fw5x-vjm9 · GitHub Advisory Database · CC BY 4.0
This product uses the NVD API but is not endorsed or certified by the NVD. Sources and licences