Authentication bypass in CIRCUTOR PowerStudio SCADA WAVE via unsigned JWT
Key facts
- Attack vector
- Network
- Privileges required
- None
- User interaction
- None
- Attack complexity
- Low
- Attack requirements
- None
- Impact type
- Security bypass
- Confidentiality · integrity · availability
- High · High · High
- Fix status
- Fixed
Attack profile from CVSS 4.0 · CNA. Fix status from CNA. Impact type from CWE-347.
Summary
An improper JWT signature verification flaw in the CIRCUTOR PowerStudio SCADA WAVE desktop version from 24.8.0 before 24.11.17.0 lets an unauthenticated remote attacker bypass authentication. The shared JWT validation component accepts an unsigned token that uses the algorithm set to none, so it does not verify a cryptographic signature (CWE-347). The attacker can impersonate another user and access protected functionality with that user's privileges. A public exploit link is listed in the references.
Written with Claude Haiku 5.5 from the sources below · 2026-11-17
Description from the CNA
An improper JWT signature verification vulnerability in CIRCUTOR PowerStudio SCADA WAVE desktop version allows an unauthenticated remote attacker to bypass authentication by submitting an unsigned JWT with the algorithm set to “none”. The shared JWT validation component accepts the token without verifying a cryptographic signature, allowing the attacker to impersonate another user and access protected functionality with that user's privileges.
Why it matters now
SSVC decision points
Not available: CISA has not published SSVC decision points for this record.
Affected products
| Vendor | Product | Affected versions | Fixed in | Status | Source |
|---|---|---|---|---|---|
| SGE-PLC1000 SGE-PLC50 | PowerStudio SCADA Wave | 24.8.0 to before 24.11.17.0 | 24.11.17.0 | Patch available | CNA |
- PowerStudio SCADA Wave VendorSGE-PLC1000 SGE-PLC50 Affected 24.8.0 to before 24.11.17.0 Fixed in 24.11.17.0 Patch available CNA
Remediation
Update CIRCUTOR PowerStudio SCADA Wave to version 24.11.17.0. The sources list no fixed version for other affected releases.
Written with Claude Haiku 5.5 from the sources below · 2026-11-17
- Fix · CNA PowerStudio SCADA Wave (Circutor) Fixed in 24.11.17.0
Timeline
- 2026-11-17 Threatist record created from CVE-2026-120387
- 2026-11-17 Alias added: GHSA-qf25-prv2-v3mp
References
More SGE-PLC1000 SGE-PLC50 vulnerabilities
- TI-2024-08251 Authentication bypass vulnerability on CIRCUTOR Q-SMT CVSS 3.1CRITICAL 10.0
- TI-2025-10798 Stack-based buffer overflow vulnreability in Circutor SGE-PLC1000/SGE-PLC50 CVSS 4.0CRITICAL 10.0
- TI-2024-08252 Insufficient Session Expiration vulnerability on CIRCUTOR Q-SMT CVSS 3.1CRITICAL 10.0
- TI-2021-13186 Circutor SGE-PLC1000 OS command Injection CVSS 3.1CRITICAL 10.0
- TI-2021-08431 Buffer overflow vulnerability in function SetFirewall in index.cgi in CIRCUTOR COMPACT… CVSS 3.1CRITICAL 9.8
- TI-2025-39821 Denial of service through specific packets CVSS 4.0CRITICAL 9.2
Sources
- CVE-2026-120387 · CVE Program
- CVE-2026-120387 · NVD
- GHSA-qf25-prv2-v3mp · GitHub Advisory Database · CC BY 4.0
This product uses the NVD API but is not endorsed or certified by the NVD. Sources and licences