Key facts
- Attack vector
- Network
- Privileges required
- None
- User interaction
- Active
- Attack complexity
- Low
- Attack requirements
- Present
- Impact type
- —
- Confidentiality · integrity · availability
- High · High · High
- Fix status
- Fixed
Attack profile from CVSS 4.0 · CNA. Fix status from CNA.
Summary
CODESYS Automation Server Connector from 1.23.0.0 before 1.40.0.0 uses server-supplied file names without sufficient path traversal checks. An unauthenticated remote attacker who controls a malicious Automation Server that a user is tricked into trusting, or who performs a man-in-the-middle attack on a trusted channel, can write attacker-controlled files to arbitrary locations on the engineering workstation (CWE-22). This can lead to arbitrary code execution with user privileges.
Written with Claude Haiku 5.5 from the sources below · 2026-11-17
Description from the CNA
The CODESYS Automation Server Connector uses server-supplied file names without sufficient path traversal checks. An unauthenticated remote attacker controlling a malicious Automation Server and tricking a user to trust it, or performing a man-in-the-middle attack on a trusted communication channel, can exploit this vulnerability to write attacker-controlled files to arbitrary locations on the engineering workstation and subsequently achieve arbitrary code execution with user privileges.
Why it matters now
SSVC decision points
Not available: CISA has not published SSVC decision points for this record.
Affected products
Remediation
Update CODESYS Automation Server Connector to version 1.40.0.0 or later.
Written with Claude Haiku 5.5 from the sources below · 2026-11-17
- Fix · CNA Automation Server Connector (CODESYS) Fixed in 1.40.0.0
Fixed in the same release
Records fixed by the same vendor advisory or release, as the CNA lists them.
- Release ·
CODESYS Automation Server Connector 1.40.0.0
3 records Highest priority Priority MEDIUM 3 MEDIUM
Other records, highest priority first
- TI-2026-92475 Improper certificate validation in CODESYS Automation Server ConnectorPriority MEDIUM 48
- TI-2026-92474 CODESYS Automation Server Connector and Service Tool: reference resolution flawPriority MEDIUM 48
Timeline
- 2026-11-17 Threatist record created from CVE-2026-118498
References
More CODESYS vulnerabilities
- TI-2021-12888 CODESYS Control Runtime system before 3.5.17.10 has a Heap-based Buffer Overflow. CVSS 3.1CRITICAL 9.8
- TI-2019-10180 Stack-based buffer overflow in CODESYS V3 web server CVSS 3.1CRITICAL 9.8
- TI-2021-13604 CODESYS V2 web server: crafted requests could trigger a null pointer dereference (DoS) CVSS 3.1HIGH 7.5
- TI-2020-08257 CODESYS V3 web server before 3.5.15.40, as used in CODESYS Control runtime systems, has a buffer overflow. CVSS 3.1CRITICAL 9.8
- TI-2019-13592 CODESYS 3 web server before 3.5.15.20, as distributed with CODESYS Control runtime systems, has a Buffer Overflow. CVSS 3.1CRITICAL 9.8
- TI-2017-03937 Unrestricted file upload in 3S-Smart Software Solutions GmbH CODESYS Web Server CVSS 3.0CRITICAL 9.8
Sources
This product uses the NVD API but is not endorsed or certified by the NVD. Sources and licences