Priority LOW 36
In Schneider Electric ClearSCADA 2014 R1 (build 75.5210) and prior, 2014 R1.1 (build 75.5387) and prior, 2015 R1 (build 76.5648) and prior, and 2015 R2 (build 77.5882) and prior, an attacker with network access to the Cl…
CVSS 3.0HIGH 7.5· Network · No auth · No interaction · EPSS 0.01635 · Published 2018-05-14 · No fix listed CWE-20
Priority LOW 35
Schneider Electric's ClearSCADA versions released prior to August 2017 are susceptible to a memory allocation vulnerability, whereby malformed requests can be sent to ClearSCADA client applications to cause unexpected be…
CVSS 3.0HIGH 7.5· Network · No auth · No interaction · EPSS 0.01034 · Published 2017-09-25 · No fix listed CWE-119
Priority LOW 30
Schneider Electric StruxureWare SCADA Expert ClearSCADA 2010 R3 through 2014 R1 uses the MD5 algorithm for an X.509 certificate, which makes it easier for remote attackers to spoof servers via a cryptographic attack agai…
CVSS 2.0MEDIUM 6.4· Network · No auth · Interaction — · EPSS 0.01028 · Published 2014-09-18 · Fixed in 2010 R3.2, 2014 R1.1 CWE-310
Priority LOW 32
Schneider Electric StruxureWare SCADA Expert ClearSCADA 2010 R3 through 2014 R1 allows remote attackers to read database records by leveraging access to the guest account.
CVSS 2.0MEDIUM 6.4· Network · No auth · Interaction — · EPSS 0.01572 · Published 2014-09-18 · Fixed in 2010 R3.2, 2014 R1.1 CWE-287
Priority LOW 25
Multiple cross-site scripting (XSS) vulnerabilities in Schneider Electric StruxureWare SCADA Expert ClearSCADA 2010 R3 through 2014 R1 allow remote authenticated users to inject arbitrary web script or HTML via unspecifi…
CVSS 2.0MEDIUM 4.9· Network · Low privileges · Interaction — · EPSS 0.01287 · Published 2014-09-18 · Fixed in 2010 R3.2, 2014 R1.1 CWE-79
Priority LOW 33
The PLC driver in ServerMain.exe in the Kepware KepServerEX 4 component in Schneider Electric StruxureWare SCADA Expert ClearSCADA 2010 R2 build 71.4165, 2010 R2.1 build 71.4325, 2010 R3 build 72.4560, 2010 R3.1 build 72…
CVSS 2.0MEDIUM 6.8· Network · No auth · Interaction — · EPSS 0.01487 · Published 2014-03-14 · No fix listed CWE-119
Priority LOW 22
DNP3Driver.exe in the DNP3 driver in Schneider Electric ClearSCADA 2010 R2 through 2010 R3.1 and SCADA Expert ClearSCADA 2013 R1 through 2013 R1.2 allows remote attackers to cause a denial of service (resource consumptio…
CVSS 2.0MEDIUM 4.3· Network · No auth · Interaction — · EPSS 0.01164 · Published 2014-01-15 · No fix listed CWE-399
Priority LOW 25
Cross-site scripting (XSS) vulnerability in Control Microsystems ClearSCADA 2005, 2007, and 2009 before R2.3 and R1.4, as used in SCX before 67 R4.5 and 68 R3.9, allows remote attackers to inject arbitrary web script or…
CVSS 2.0MEDIUM 4.3· Network · No auth · Interaction — · EPSS 0.02509 · Published 2011-08-16 · No fix listed CWE-79
Priority MEDIUM 53
Use-after-free vulnerability in Control Microsystems ClearSCADA 2005, 2007, and 2009 before R2.3 and R1.4, as used in SCX before 67 R4.5 and 68 R3.9, allows remote attackers to cause a denial of service (crash) and possi…
CVSS 2.0HIGH 10.0· Network · No auth · Interaction — · EPSS 0.07506 · Published 2011-08-16 · No fix listed CWE-399