TI-2025-35607 CVE-2025-57700 · GHSA-gqg5-mc9f-px29

Stored Cross-site Scripting in DIAEnergie

Priority LOW 30

DIAEnergie - Stored Cross-site Scripting

CVSS 4.0HIGH 7.0 Network Low privileges User interaction EPSS 0.002 Published 2025-08-18 No fix listed CWE-79
TI-2024-28395 CVE-2024-42417 · GHSA-hf9q-vp6q-vfw5

Delta Electronics DIAEnergie SQL Injection

Priority MEDIUM 50

Delta Electronics DIAEnergie is vulnerable to an SQL injection in the script Handler_CFG.ashx.

CVSS 4.0HIGH 8.7 Network Low privileges No interaction EPSS 0.07026 Published 2024-10-03 No fix listed CWE-89
TI-2024-29300 CVE-2024-43699 · GHSA-4ggp-xr27-wmh2

Delta Electronics DIAEnergie SQL Injection

Priority MEDIUM 49

Delta Electronics DIAEnergie is vulnerable to an SQL injection in the script AM_RegReport.aspx.

CVSS 4.0CRITICAL 9.3 Network No auth No interaction EPSS 0.0054 Published 2024-10-03 No fix listed CWE-89
TI-2024-04235 CVE-2024-4549 · GHSA-2252-jwp3-qxfh

Delta Electronics DIAEnergie SQL Injection

Priority HIGH 72

A denial of service vulnerability exists in Delta Electronics DIAEnergie v1.10.1.8610 and prior.

CVSS 3.1HIGH 7.5 Network No auth No interaction EPSS 0.01109 Published 2024-05-06 No fix listed CWE-400
TI-2024-04234 CVE-2024-4548 · GHSA-m7ww-c868-pgpq

Delta Electronics DIAEnergie SQL Injection

Priority HIGH 72

An SQLi vulnerability exists in Delta Electronics DIAEnergie v1.10.1.8610 and prior when CEBC.exe processes a 'RecalculateHDMWYC' message, which is split into 4 fields using the '~' character as the separator.

CVSS 3.1CRITICAL 9.8 Network No auth No interaction EPSS 0.29425 Published 2024-05-06 No fix listed CWE-20
Priority MEDIUM 52

A SQLi vulnerability exists in Delta Electronics DIAEnergie v1.10.1.8610 and prior when CEBC.exe processes a 'RecalculateScript' message, which is splitted into 4 fields using the '~' character as the separator.

CVSS 3.1CRITICAL 9.8 Network No auth No interaction EPSS 0.01895 Published 2024-05-06 No fix listed CWE-20
Priority MEDIUM 42

Delta Electronics DIAEnergie has insufficient input validation which makes it possible to perform a path traversal attack and write outside of the intended directory.

CVSS 3.1HIGH 8.8 Network Low privileges No interaction EPSS 0.01 Published 2024-05-03 No fix listed CWE-22
Priority MEDIUM 41

Delta Electronics DIAEnergie is vulnerable to an SQL injection vulnerability that exists in the script Handler_CFG.ashx.

CVSS 3.1HIGH 8.8 Network Low privileges No interaction EPSS 0.00499 Published 2024-05-03 No fix listed CWE-89
Priority MEDIUM 51

Delta Electronics DIAEnergie is vulnerable to an SQL injection vulnerability that exists in the GetDIACloudList endpoint.

CVSS 3.1HIGH 8.8 Network Low privileges No interaction EPSS 0.08742 Published 2024-05-03 No fix listed CWE-89
TI-2024-16808 CVE-2024-25574 · GHSA-8679-mqj6-8992

Delta Electronics DIAEnergie SQL Injection

Priority MEDIUM 54

SQL injection vulnerability exists in GetDIAE_usListParameters.

CVSS 3.1CRITICAL 9.8 Network No auth No interaction EPSS 0.0879 Published 2024-04-01 Fixed in v1.10.00.005 CWE-89
Priority LOW 24

Improper neutralization of input within the affected product could lead to cross-site scripting.

CVSS 3.1MEDIUM 5.4 Network Low privileges User interaction EPSS 0.00293 Published 2024-03-21 Fixed in v1.10.00.005 CWE-79
TI-2024-16802 CVE-2024-25567 · GHSA-mgcc-v376-cqg5

Delta Electronics DIAEnergie Path traversal

Priority LOW 39

Path traversal attack is possible and write outside of the intended directory and may access sensitive information.

CVSS 3.1HIGH 8.8 Network Low privileges No interaction EPSS 0.00661 Published 2024-03-21 Fixed in v1.10.00.005 CWE-22
TI-2024-18749 CVE-2024-28171 · GHSA-99h3-9g3j-xw8m

Delta Electronics DIAEnergie Path traversal

Priority HIGH 68

It is possible to perform a path traversal attack and write outside of the intended directory.

CVSS 3.1HIGH 8.1 Network Low privileges No interaction EPSS 0.00646 Published 2024-03-21 Fixed in v1.10.00.005 CWE-22
TI-2024-15537 CVE-2024-23494 · GHSA-62q9-cpw9-7wq5

Delta Electronics DIAEnergie SQL injection

Priority MEDIUM 51

SQL injection vulnerability exists in GetDIAE_unListParameters.

CVSS 3.1HIGH 8.8 Network Low privileges No interaction EPSS 0.08484 Published 2024-03-21 Fixed in v1.10.00.005 CWE-89
TI-2024-15950 CVE-2024-23975 · GHSA-28pm-frw8-mr59

Delta Electronics DIAEnergie SQL injection

Priority MEDIUM 51

SQL injection vulnerability exists in GetDIAE_slogListParameters.

CVSS 3.1HIGH 8.8 Network Low privileges No interaction EPSS 0.08484 Published 2024-03-21 Fixed in v1.10.00.005 CWE-89
TI-2024-18634 CVE-2024-28040 · GHSA-w8xc-6w99-h267

Delta Electronics DIAEnergie SQL injection

Priority MEDIUM 51

SQL injection vulnerability exists in GetDIAE_astListParameters.

CVSS 3.1HIGH 8.8 Network Low privileges No interaction EPSS 0.08484 Published 2024-03-21 Fixed in v1.10.00.005 CWE-89
TI-2024-17037 CVE-2024-25937 · GHSA-hf8q-wrgf-872g

Delta Electronics DIAEnergie SQL injection

Priority MEDIUM 51

SQL injection vulnerability exists in the script DIAE_tagHandler.ashx.

CVSS 3.1HIGH 8.8 Network Low privileges No interaction EPSS 0.08484 Published 2024-03-21 Fixed in v1.10.00.005 CWE-89
TI-2024-19086 CVE-2024-28891 · GHSA-mpfr-43f5-3jjf

Delta Electronics DIAEnergie SQL injection

Priority MEDIUM 51

SQL injection vulnerability exists in the script Handler_CFG.ashx.

CVSS 3.1HIGH 8.8 Network Low privileges No interaction EPSS 0.08484 Published 2024-03-21 Fixed in v1.10.00.005 CWE-89
Priority MEDIUM 41

The affected product DIAEnergie (versions prior to v1.9.03.001) contains improper authorization, which could allow an unauthorized user to bypass authorization and access privileged functionality.

CVSS 3.1HIGH 8.8 Network Low privileges No interaction EPSS 0.00634 Published 2023-02-17 Fixed in v1.9.03.001 CWE-285
TI-2022-21290 CVE-2022-43506 · GHSA-grqp-gq33-35cw

Delta Electronics DIAEnergie SQL Injection

Priority MEDIUM 41

SQL Injection in HandlerTag_KID.ashx in Delta Electronics DIAEnergie versions prior to v1.9.02.001 allows an attacker to inject SQL queries via Network

CVSS 3.1HIGH 8.8 Network Low privileges No interaction EPSS 0.00765 Published 2022-11-17 No fix listed CWE-89
TI-2022-20151 CVE-2022-41775 · GHSA-37xx-28hh-jqxc

Delta Electronics DIAEnergie SQL Injection

Priority MEDIUM 41

SQL Injection in Handler_CFG.ashx in Delta Electronics DIAEnergie versions prior to v1.9.02.001 allows an attacker to inject SQL queries via Network

CVSS 3.1HIGH 8.8 Network Low privileges No interaction EPSS 0.00691 Published 2022-11-17 No fix listed CWE-89
Load more