Priority MEDIUM 45
There is Memory corruption in the web interface of Moxa OnCell G3100-HSPA Series version 1.5 Build 17042015 and prio,r a different vulnerability than CVE-2018-11423.
CVSS 3.0CRITICAL 9.8· Network · No auth · No interaction · EPSS 0.0154 · Published 2019-07-03 · No fix listed CWE-787
Priority MEDIUM 44
Moxa OnCell G3100-HSPA Series version 1.6 Build 17100315 and prior use a proprietary monitoring protocol that does not provide confidentiality, integrity, and authenticity security controls.
CVSS 3.0CRITICAL 9.8· Network · No auth · No interaction · EPSS 0.00906 · Published 2019-07-03 · No fix listed CWE-319
Priority MEDIUM 44
Moxa OnCell G3100-HSPA Series version 1.6 Build 17100315 and prior use a proprietary configuration protocol that does not provide confidentiality, integrity, and authenticity security controls.
CVSS 3.0CRITICAL 9.8· Network · No auth · No interaction · EPSS 0.01022 · Published 2019-07-03 · No fix listed CWE-319
Priority LOW 36
There is Memory corruption in the web interface Moxa OnCell G3100-HSPA Series version 1.6 Build 17100315 and prior, different vulnerability than CVE-2018-11420.
CVSS 3.0HIGH 7.5· Network · No auth · No interaction · EPSS 0.0136 · Published 2019-07-03 · No fix listed CWE-119
Priority MEDIUM 46
A weak Cookie parameter is used in the web application of Moxa OnCell G3100-HSPA Series version 1.4 Build 16062919 and prior.
CVSS 3.0CRITICAL 9.8· Network · No auth · No interaction · EPSS 0.01841 · Published 2019-07-03 · No fix listed CWE-287
Priority LOW 39
CSRF tokens are not used in the web application of Moxa OnCell G3100-HSPA Series version 1.4 Build 16062919 and prior, which makes it possible to perform CSRF attacks on the device administrator.
CVSS 3.0HIGH 8.8· Network · No auth · User interaction · EPSS 0.00579 · Published 2019-07-03 · No fix listed CWE-352
Priority MEDIUM 45
A Reliance on Cookies without Validation and Integrity Checking issue was discovered in Moxa OnCell G3100-HSPA Series version 1.4 Build 16062919 and prior.
CVSS 3.0CRITICAL 9.8· Network · No auth · No interaction · EPSS 0.01561 · Published 2018-03-05 · No fix listed CWE-565
Priority LOW 35
An Improper Handling of Length Parameter Inconsistency issue was discovered in Moxa OnCell G3100-HSPA Series version 1.4 Build 16062919 and prior.
CVSS 3.0HIGH 7.5· Network · No auth · No interaction · EPSS 0.01182 · Published 2018-03-05 · No fix listed CWE-130
Priority LOW 29
A NULL Pointer Dereference issue was discovered in Moxa OnCell G3100-HSPA Series version 1.4 Build 16062919 and prior.
CVSS 3.0MEDIUM 6.5· Adjacent network · No auth · No interaction · EPSS 0.00484 · Published 2018-03-05 · No fix listed CWE-476