RECWAVE Filepath Traversal
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability in CRESTRON TOUCHSCREENS x70 allows Relative Path Traversal.This issue affects TOUCHSCREENS x70: from 3.000.0110.001 before 3.0…
47 records
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability in CRESTRON TOUCHSCREENS x70 allows Relative Path Traversal.This issue affects TOUCHSCREENS x70: from 3.000.0110.001 before 3.0…
A vulnerability exists in the ConsoleFindCommandMatchList function in libsymproc.
Improper Neutralization of Argument Delimiters in a Command ('Argument Injection') vulnerability in CRESTRON TOUCHSCREENS x70 allows Argument Injection.This issue affects TOUCHSCREENS x70: from 3.001.0031.001 through 3.0…
266 vulnerability in Crestron Automate VX allows Privilege Escalation.This issue affects Automate VX: from 5.6.8161.21536 through 6.4.0.49.
Cleartext Transmission of Sensitive Information vulnerability in Crestron Automate VX allows Sniffing Network Traffic.
Exposure of Sensitive Information to an Unauthorized Actor vulnerability in Crestron Automate VX allows Functionality Misuse.
Exposure of Sensitive Information to an Unauthorized Actor vulnerability in Crestron Automate VX allows Functionality Misuse.
There is an OS command injection vulnerability in Crestron AM-300 firmware version 1.4499.00018 which may enable a user of a limited-access SSH session to escalate their privileges to root-level access.
On Crestron 3-Series Control Systems before 1.8001.0187, crafting and sending a specific BACnet packet can cause a crash.
Crestron AirMedia for Windows before 5.5.1.84 has insecure inherited permissions, which leads to a privilege escalation vulnerability found in the AirMedia Windows Application, version 4.3.1.39.
A vulnerability was discovered in the Crestron AirMedia Windows Application, version 4.3.1.39, in which a user can place a malicious DLL in a certain path to execute code and preform a privilege escalation attack.
Insufficient access control vulnerability was discovered in the Crestron AirMedia Windows Application, version 4.3.1.39, in which a user can pause the uninstallation of an executable to gain a SYSTEM level command prompt…
A vulnerability was discovered in the Crestron AirMedia Windows Application, version 4.3.1.39, in which a low-privileged user can gain a SYSTEM level command prompt by pre-staging a file structure prior to the installati…
An issue was discovered on Crestron HD-MD4X2-4K-E 1.0.0.2159 devices.
On Crestron DM-NVX-DIR, DM-NVX-DIR80, and DM-NVX-ENT devices before the DM-XIO/1-0-3-802 patch, the password can be changed by sending an unauthenticated WebSocket request.
Crestron DMC-STRO 1.0 devices allow remote command execution as root via shell metacharacters to the ping function.
Crestron AM-100 with firmware 1.6.0.2 and AM-101 with firmware 2.7.0.2 use default credentials admin/admin and moderator/moderator for the web interface.
Crestron AM-100 with firmware 1.6.0.2 and AM-101 with firmware 2.7.0.2 stores usernames, passwords, and other configuration options in the file generated via the "export configuration" feature.
Crestron AM-100 with firmware 1.6.0.2 and AM-101 with firmware 2.7.0.2 stores usernames, passwords, slideshow passcode, and other configuration options in cleartext in the file /tmp/scfgdndf.
Crestron AM-100 with firmware 1.6.0.2 and AM-101 with firmware 2.7.0.2 is vulnerable to denial of service via a crafted request to TCP port 389.
Crestron AM-100 with firmware 1.6.0.2 and AM-101 with firmware 2.7.0.2 allows anyone to act as a moderator to a slide show via crafted HTTP POST requests to conference.cgi.
Crestron AM-100 with firmware 1.6.0.2 and AM-101 with firmware 2.7.0.2 allows anyone to bypass the presentation code sending a crafted HTTP POST request to login.cgi.
Crestron AM-100 with firmware 1.6.0.2 and AM-101 with firmware 2.7.0.2 allows anyone to bypass the presentation code simply by requesting /images/browserslide.jpg via HTTP.
Crestron AM-100 with firmware 1.6.0.2 and AM-101 with firmware 2.7.0.2 are vulnerable to authentication bypass due to a hard-coded password in return.tgi.
Crestron AM-100 with firmware 1.6.0.2 and AM-101 with firmware 2.7.0.2 are vulnerable to argumention injection to the curl binary via crafted HTTP requests to return.cgi.