SQL injection in Subnet Solutions PowerSYSTEM Center report designer
Insufficient input validation in the PowerSYSTEM Center report designer allows an authenticated user to execute unauthorized SQL commands.
16 records
Insufficient input validation in the PowerSYSTEM Center report designer allows an authenticated user to execute unauthorized SQL commands.
Incorrect authorization in PowerSYSTEM Center allows a low-privileged, authenticated user to access resources normally limited to administrators.
PowerSYSTEM Center REST API endpoint for device account export allows an authenticated user with limited permissions to expose sensitive information normally restricted to administrative permissions only.
PowerSYSTEM Center REST API endpoint for devices allows a low privilege authenticated user to access information normally limited by operational permissions.
PowerSYSTEM Center feature for device project groups allows an authenticated user with limited permissions to perform an unauthorized deletion of project groups.
PowerSYSTEM Center email notification service is affected by a CRLF injection vulnerability when using SMTPS communication.
Subnet Solutions PowerSYSTEM Center is affected by a mishandling of exceptional conditions vulnerability.
Subnet Solutions PowerSYSTEM Center's SMTPS notification service can be affected by importing an EC certificate with crafted F2m parameters, which can lead to excessive CPU consumption during the evaluation of the curve…
SUBNET Solutions Inc. has identified vulnerabilities in third-party components used in Substation Server.
SUBNET Solutions Inc. has identified vulnerabilities in third-party components used in PowerSYSTEM Center.
SUBNET Solutions Inc. has identified vulnerabilities in third-party components used in PowerSYSTEM Server 2021 and Substation Server 2021.
PowerSYSTEM Center versions 2020 Update 16 and prior contain a vulnerability that may allow an authorized local user to insert arbitrary code into the unquoted service path and escalate privileges.
SUBNET PowerSYSTEM Center versions 2020 U10 and prior contain a cross-site scripting vulnerability that may allow an attacker to inject malicious code into report header graphic files that could propagate out of the syst…
SUBNET PowerSYSTEM Center versions 2020 U10 and prior are vulnerable to replay attacks which may result in a denial-of-service condition or a loss of data integrity.
The GPT library in the Telegyr 8979 Master Protocol application in SUBNET SubSTATION Server 2 before SSNET 2.12 HF18808 allows remote attackers to cause a denial of service (persistent service crash) via a long RTU-to-Ma…
The DNP3 Slave service in SUBNET Solutions SubSTATION Server 2.7.0033 and 2.8.0106 allows remote attackers to cause a denial of service (unhandled exception and process crash) via unspecified vectors.