Incorrect Permission Assignment on power analyzer
An unauthenticated remote attacker who tricks a user to upload a manipulated HTML file can get access to sensitive information on the device.
35 records
An unauthenticated remote attacker who tricks a user to upload a manipulated HTML file can get access to sensitive information on the device.
An unauthenticated remote attacker can use firmware images to extract password hashes and brute force plaintext passwords of accounts with limited access.
An unauthenticated remote attacker may use hardcodes credentials to get access to the previously activated FTP Server with limited read and write privileges.
An unauthenticated remote attacker can perform a command injection via Modbus-TCP or Modbus-RTU to gain read and write access on the affected device.
An unauthenticated remote attacker may use a stack based buffer overflow in the u-link Management API to gain full access on the affected devices.
An authenticated remote attacker can execute arbitrary commands with root privileges on affected devices due to lack of improper sanitizing of user input in the Main Web Interface (endpoint tls_iotgen_setting).
An authenticated remote attacker can execute arbitrary commands with root privileges on affected devices due to lack of improper sanitizing of user input in the Main Web Interface (endpoint event_mail_test).
For u-link Management API an unauthenticated remote attacker in a man-in-the-middle position can inject arbitrary commands in responses returned by WWH servers, which are then executed with elevated privileges.
An unauthenticated remote attacker can execute arbitrary commands with root privileges on affected devices due to lack of Cross-Site Request Forgery (CSRF) protection.
An unauthenticated remote attacker can exploit a denial-of-service vulnerability in the device's web server functionality by sending a specially crafted HTTP request with a malicious header, potentially causing the serve…
The devices are vulnerable to an authentication bypass due to flaws in the authorization mechanism.
Due to missing authentication on a critical function of the devices an unauthenticated remote attacker can execute arbitrary commands, potentially enabling unauthorized upload or download of configuration files and leadi…
An unauthenticated remote attacker can exploit input validation in cmd services of the devices, allowing them to disrupt system operations and potentially cause a denial-of-service.
An unauthenticated remote attacker can exploit insufficient input validation to write data beyond the bounds of a buffer, potentially leading to a denial-of-service condition for the devices.
An unauthenticated remote attacker can use hard-coded credentials to gain full administration privileges on the affected product.
Quanos "SCHEMA ST4" example web templates in version Bootstrap 2019 v2/2021 v1/2022 v1/2022 SP1 v1 or below are prone to JavaScript injection allowing a remote attacker to hijack existing sessions to e.g.
In Weidmueller Industrial WLAN devices in multiple versions an exploitable authentication bypass vulnerability exists in the hostname processing.
In Weidmueller Industrial WLAN devices in multiple versions an exploitable improper access control vulnerability exists in the iw_webs account settings functionality.
In Weidmueller Industrial WLAN devices in multiple versions an exploitable remote code execution vulnerability exists in the iw_webs configuration parsing functionality.
In Weidmueller Industrial WLAN devices in multiple versions an exploitable denial-of-service vulnerability exists in ServiceAgent functionality.
In Weidmueller Industrial WLAN devices in multiple versions an exploitable format string vulnerability exists in the iw_console conio_writestr functionality.
In Weidmueller Industrial WLAN devices in multiple versions an exploitable command injection vulnerability exists in the hostname functionality.
In Weidmueller Industrial WLAN devices in multiple versions an exploitable command injection vulnerability exists in the iw_webs functionality.
In Weidmueller Industrial WLAN devices in multiple versions an exploitable command injection vulnerability exists in the iw_webs functionality.
In Weidmueller Industrial WLAN devices in multiple versions an exploitable use of hard-coded credentials vulnerability exists in multiple iw_* utilities.