Priority MEDIUM 48
BD Alaris Gateway Workstation Versions, 1.1.3 Build 10, 1.1.3 MR Build 11, 1.2 Build 15, 1.3.0 Build 14, 1.3.1 Build 13, This does not impact the latest firmware Versions 1.3.2 and 1.6.1, Additionally, the following prod…
CVSS 3.0CRITICAL 10.0· Network · No auth · No interaction · EPSS 0.02528 · Published 2019-06-13 · No fix listed CWE-434
Priority MEDIUM 46
Becton, Dickinson and Company (BD) Alaris Plus medical syringe pumps (models Alaris GS, Alaris GH, Alaris CC, and Alaris TIVA) versions 2.3.6 and prior are affected by an improper authentication vulnerability where the s…
CVSS 3.0CRITICAL 9.4· Network · No auth · No interaction · EPSS 0.02942 · Published 2018-08-23 · No fix listed CWE-287
Priority MEDIUM 46
A hard-coded password issue was discovered in Becton, Dickinson and Company (BD) PerformA, Version 2.0.14.0 and prior versions, and KLA Journal Service, Version 1.0.51 and prior versions.
CVSS 3.0CRITICAL 9.8· Network · No auth · No interaction · EPSS 0.01752 · Published 2017-06-30 · No fix listed CWE-259
Priority MEDIUM 41
In Pyxis ES Versions 1.3.4 through to 1.6.1 and Pyxis Enterprise Server, with Windows Server Versions 4.4 through 4.12, a vulnerability has been identified where existing access privileges are not restricted in coordinat…
CVSS 3.0HIGH 8.8· Network · Low privileges · No interaction · EPSS 0.01288 · Published 2019-09-06 · No fix listed CWE-384
Priority LOW 38
Specific BD Pyxis™ products were installed with default credentials and may presently still operate with these credentials.
CVSS 3.1HIGH 8.8· Adjacent network · No auth · No interaction · EPSS 0.00425 · Published 2022-06-01 · No fix listed CWE-262
Priority LOW 36
Default credentials are used in the above listed BD Diagnostic Solutions products.
CVSS 3.1HIGH 8.0· Adjacent network · Low privileges · No interaction · EPSS 0.00236 · Published 2024-12-17 · No fix listed CWE-1392
Priority LOW 36
A malicious file could be uploaded into a System Manager User Import Function resulting in a hijacked session.
CVSS 3.1HIGH 8.2· Network · No auth · User interaction · EPSS 0.00439 · Published 2023-07-13 · No fix listed CWE-79
Priority LOW 36
BD Alaris PC Unit, Model 8015, Versions 9.33.1 and earlier and BD Alaris Systems Manager, Versions 4.33 and earlier The affected products are vulnerable to a network session authentication vulnerability within the authen…
CVSS 3.1HIGH 7.5· Network · No auth · No interaction · EPSS 0.01715 · Published 2020-11-13 · No fix listed CWE-287
Priority LOW 34
BD Viper LT system, versions 2.0 and later, contains hardcoded credentials.
CVSS 3.1HIGH 8.0· Local · No auth · No interaction · EPSS 0.00231 · Published 2022-02-12 · No fix listed CWE-798
Priority LOW 33
The Alaris Infusion Central software, versions 1.1 to 1.3.2, may contain a recoverable password after the installation.
CVSS 3.1HIGH 7.3· Local · Low privileges · No interaction · EPSS 0.00162 · Published 2023-06-13 · No fix listed CWE-257
Priority LOW 33
BD Totalys MultiProcessor, versions 1.70 and earlier, contain hardcoded credentials.
CVSS 3.1HIGH 7.8· Local · Low privileges · No interaction · EPSS 0.00173 · Published 2022-11-04 · No fix listed CWE-798
Priority LOW 32
The configuration from the PCU can be modified without authentication using physical connection to the PCU.
CVSS 3.1MEDIUM 6.8· Physical · No auth · No interaction · EPSS 0.00303 · Published 2023-07-13 · No fix listed CWE-287
Priority LOW 30
Alaris Systems Manager does not perform input validation during the Device Import Function.
CVSS 3.1MEDIUM 6.9· Adjacent network · Low privileges · User interaction · EPSS 0.00286 · Published 2023-07-13 · No fix listed CWE-79
Priority LOW 30
Hardcoded credentials are used in specific BD Pyxis products.
CVSS 3.1HIGH 7.0· Local · Low privileges · No interaction · EPSS 0.00228 · Published 2022-02-11 · No fix listed CWE-798
Priority LOW 30
BD FACSLyric Research Use Only, Windows 10 Professional Operating System, U.S.
CVSS 3.1MEDIUM 6.8· Physical · No auth · No interaction · EPSS 0.00417 · Published 2019-02-06 · No fix listed CWE-284
Priority LOW 29
A GRE dataset file within Systems Manager can be tampered with and distributed to PCUs.
CVSS 3.1MEDIUM 6.7· Adjacent network · Low privileges · User interaction · EPSS 0.00178 · Published 2023-07-13 · No fix listed CWE-345
Priority LOW 28
A vulnerability in ReadA version 1.1.0.2 and previous allows an authorized user with access to a privileged account on a BD Kiestra system (Kiestra TLA, Kiestra WCA, and InoqulA+ specimen processor) to issue SQL commands…
CVSS 3.0MEDIUM 6.3· Adjacent network · High privileges · User interaction · EPSS 0.00407 · Published 2018-05-24 · No fix listed CWE-356
Priority LOW 27
In BD Pyxis MedStation ES System v1.6.1 and Pyxis Anesthesia (PAS) ES System v1.6.1, a restricted desktop environment escape vulnerability exists in the kiosk mode functionality of affected devices.
CVSS 3.1MEDIUM 6.1· Physical · No auth · No interaction · EPSS 0.00334 · Published 2020-04-01 · No fix listed CWE-693
Priority LOW 27
BD Alaris Gateway versions, 1.0.13,1.1.3 Build 10,1.1.3 MR Build 11,1.1.5, and 1.1.6, The web browser user interface on the Alaris Gateway Workstation does not prevent an attacker with knowledge of the IP address of the…
CVSS 3.1MEDIUM 5.3· Network · No auth · No interaction · EPSS 0.01675 · Published 2019-06-13 · No fix listed CWE-284
Priority LOW 26
The data flowing between the PCU and its modules is insecure.
CVSS 3.1MEDIUM 6.1· Physical · No auth · No interaction · EPSS 0.00189 · Published 2023-07-13 · No fix listed CWE-311
Priority LOW 25
The firmware update package for the wireless card is not properly signed and can be modified.
CVSS 3.1MEDIUM 5.7· Physical · No auth · No interaction · EPSS 0.00177 · Published 2023-07-13 · No fix listed CWE-20
Priority LOW 25
The FACSChorus workstation operating system does not restrict what devices can interact with its USB ports.
CVSS 3.1MEDIUM 5.7· Physical · No auth · No interaction · EPSS 0.003 · Published 2023-11-28 · No fix listed CWE-1299
Priority LOW 25
BD Synapsys™, versions 4.20, 4.20 SR1, and 4.30, contain an insufficient session expiration vulnerability.
CVSS 3.1MEDIUM 5.7· Physical · Low privileges · User interaction · EPSS 0.00232 · Published 2022-06-01 · No fix listed CWE-613
Priority LOW 25
A vulnerability in DB Manager version 3.0.1.0 and previous and PerformA version 3.0.0.0 and previous allows an authorized user with access to a privileged account on a BD Kiestra system (Kiestra TLA, Kiestra WCA, and Ino…
CVSS 3.0MEDIUM 5.6· Adjacent network · High privileges · User interaction · EPSS 0.00361 · Published 2018-05-24 · No fix listed CWE-356
Priority LOW 25
An issue was discovered in Becton, Dickinson and Company (BD) Alaris 8015 Point of Care (PC) unit, Version 9.5 and prior versions, and Version 9.7.
CVSS 3.0MEDIUM 5.3· Physical · No auth · No interaction · EPSS 0.0051 · Published 2017-02-13 · No fix listed CWE-255