Improper Authentication Mechanism in B&R VC4 Visualization
Improper Authentication vulnerability in B&R Industrial Automation B&R VC4 (VNC-Server modules).
No B&R Industrial Automation vulnerabilities are listed in CISA KEV.
69 records
Improper Authentication vulnerability in B&R Industrial Automation B&R VC4 (VNC-Server modules).
Insufficient validation of input parameters when changing configuration on Tbase server in B&R APROL versions < R 4.2-07 could result in buffer overflow.
Lack of verification in B&R APROL Tbase server versions < R 4.2-07 may lead to memory leaks when receiving messages
Missing authentication when creating and managing the B&R APROL database in versions < R 4.2-07 allows reading and changing the system configuration.
An improper control of generation of code ('Code Injection') vulnerability in the AprolCreateReport component of B&R APROL <4.4-00P5 may allow an unauthenticated network-based attacker to read files from the local system…
The FTP server used on the B&R Automation Runtime supports unsecure encryption mechanisms, such as SSLv3, TLSv1.0 and TLS1.1.
An Improper Resource Locking vulnerability in the SDM component of B&R Automation Runtime versions before 6.3 and before Q4.93 may allow an unauthenticated network-based attacker to delete data causing denial of service…
An issue was discovered in B&R Industrial Automation APROL before R4.2 V7.08.
An issue was discovered in B&R Industrial Automation APROL before R4.2 V7.08.
An Allocation of Resources Without Limits or Throttling vulnerability in the OPC-UA Server used in PPT30 Operating System versions before 1.8.0 may be used by an unauthenticated network-based attacker to permanently prev…
Improper initialization implementation in Portmapper used in B&R Industrial Automation Automation Runtime <G4.93 allows unauthenticated network-based attackers to cause permanent denial-of-service conditions.
Improper Input Validation vulnerability in the project upload mechanism in B&R Automation Studio version >=4.0 may allow an unauthenticated network attacker to execute code.
An issue was discovered in B&R Industrial Automation APROL before R4.2 V7.08.
An issue was discovered in B&R Industrial Automation APROL before R4.2 V7.08.
An authentication weakness in the SNMP service in B&R Automation Runtime versions 2.96, 3.00, 3.01, 3.06 to 3.10, 4.00 to 4.63, 4.72 and above allows unauthenticated users to modify the configuration of B&R products via…
A “Use of a Broken or Risky Cryptographic Algorithm” vulnerability in the SSL/TLS component used in B&R Automation Runtime versions before 6.1 and B&R mapp View versions before 6.1 may be abused by unauthenticated networ…
Improper certificate validation vulnerability in B&R Industrial Automation GmbH APROL.
B&R APROL versions < R 4.2-07 doesn’t process correctly specially formatted data packages sent to port 55502/tcp, which may allow a network based attacker to cause an application Denial-of-Service.
Insufficient check of preconditions could lead to Denial of Service conditions when calling commands on the Tbase server of B&R APROL versions < R 4.2-07.
An Allocation of Resources Without Limits or Throttling vulnerability in the ANSL-Server component of B&R Automation Runtime versions prior to 6.5 and prior to R4.93 could be exploited by an unauthenti-cated attacker on…
An Improper Certificate Validation vulnerability in the OPC-UA client and ANSL over TLS client used in Automation Studio versions before 6.5 could allow an unauthenticated attacker on the network to position themselves t…
An Exposure of Sensitive System Information to an Unauthorized Control Sphere and Initialization of a Resource with an Insecure Default vulnerability in the SNMP component of B&R APROL <4.4-00P5 may allow an unauthentica…
Buffer Overflow vulnerability in B&R Automation Runtime webserver allows an unauthenticated network-based attacker to stop the cyclic program on the device and cause a denial of service.
Incorrect Permission Assignment for Critical Resource vulnerability in B&R Industrial Automation Automation Studio allows Privilege Escalation.This issue affects Automation Studio: from 4.6.0 through 4.6.X, from 4.7.0 be…
Untrusted Search Path vulnerability in B&R Industrial Automation GmbH APROL.