An authentication weakness in the SNMP service in B&R Automation Runtime versions 2.96, 3.00, 3.01, 3.06 to 3.10, 4.00 to 4.63, 4.72 and above allows unauthenticated users to modify the configuration of B&R products via…
Incorrect Permission Assignment for Critical Resource vulnerability in B&R Industrial Automation Automation Studio allows Privilege Escalation.This issue affects Automation Studio: from 4.6.0 through 4.6.X, from 4.7.0 be…
B&R Automation Studio Upgrade Service and B&R Technology Guarding use insufficient cryptography for communication to the upgrade and the licensing servers.
CVSS 3.1HIGH 8.3·Network·No auth·User interaction·EPSS 0.00364·Published 2024-02-22·Fixed in 4.6, 1.4.0CWE-1240
Improper Control of Generation of Code ('Code Injection') vulnerability in B&R Industrial Automation Automation Studio allows Local Execution of Code.This issue affects Automation Studio: from 4.0 through 4.12.
A directory traversal vulnerability in SharpZipLib used in the upgrade service in B&R Automation Studio versions 4.0.x, 4.1.x and 4.2.x allow unauthenticated users to write to certain local directories.
Improper DLL loading algorithms in B&R Automation Studio versions >=4.0 and <4.12 may allow an authenticated local attacker to execute code in the context of the product.
CVSS 3.1HIGH 7.2·Local·High privileges·User interaction·EPSS 0.00166·Published 2024-05-14·Fixed in 4.12CWE-20
A privilege escalation vulnerability in the upgrade service in B&R Automation Studio versions 4.0.x, 4.1.x, 4.2.x, < 4.3.11SP, < 4.4.9SP, < 4.5.4SP, <.
A missing secure communication definition and an incomplete TLS validation in the upgrade service in B&R Automation Studio versions 4.0.x, 4.1.x, 4.2.x, < 4.3.11SP, < 4.4.9SP, < 4.5.5SP, < 4.6.4 and < 4.7.2 enable unauth…