Authenticated remote code execution in HMS Networks Ewon Flexy 205
A code injection vulnerability in HMS Networks Ewon Flexy 205 allows executing commands on system level on the device.
No HMS Networks vulnerabilities are listed in CISA KEV.
20 records
A code injection vulnerability in HMS Networks Ewon Flexy 205 allows executing commands on system level on the device.
EWON Flexy 202 transmits user credentials in clear text with no encryption when a user is added, or user credentials are changed via its webpage.
HMS Industrial Networks AB eCatcher all versions prior to 6.5.5 is vulnerable to a stack-based buffer overflow, which may allow an attacker to remotely execute arbitrary code.
A compromised HMS Networks Cosy+ device could be used to request a Certificate Signing Request from Talk2m for another device, resulting in an availability issue.
Insecure Permission vulnerability in Cosy+ devices running a firmware 21.x below 21.2s10 or a firmware 22.x below 22.1s3 are executing several processes with elevated privileges.
Insecure Permissions vulnerability in Cosy+ devices running a firmware 21.x below 21.2s10 or a firmware 22.x below 22.1s3 are susceptible to leaking information through cookies.
Cosy+ devices running a firmware 21.x below 21.2s10 or a firmware 22.x below 22.1s3 are vulnerable to code injection due to improper parameter blacklisting.
The PEAK-System PCAN parser indexes a length table using attacker-controlled DLC without enforcing DLC <= 0x0f, then copies attacker payload from record+0x1c into a fixed-size stack destination.
The EWON FLEXY 202 transmits credentials using a weak encoding method base64.
Cosy+ devices running a firmware 21.x below 21.2s10 or a firmware 22.x below 22.1s3 use a unique key to encrypt the configuration parameters.
HMS Industrial Networks Netbiter WS100 3.30.5 devices and previous have reflected XSS in the login form.
The PEAK-System PCAN type 0x4030 processing path fails to validate a selected/returned object pointer before dereferencing fixed fields during post-processing.
The parser in PEAK-System PCAN driver correctly detected the malformed record, but the loop iterating the record list advanced its processed-bytes counter even when a record had been rejected as invalid.
PEAK-System PCAN contains a vulnerable operation involving a variable-length receive-record copy.
The PEAK-System PCAN diagnostic call did not validate that the caller-supplied output buffer was large enough to hold the output record.
Cosy+ devices running a firmware 21.x below 21.2s10 or a firmware 22.x below 22.1s3 are vulnerable to XSS when displaying the logs due to improper input sanitization.
HMS Industrial Networks Anybus-CompactCom 30 products are vulnerable to a XSS attack caused by the lack of input sanitation checks.
In HMS Ewon eCatcher through 6.6.4, weak filesystem permissions could allow malicious users to access files that could lead to sensitive information disclosure, modification of configuration files, or disruption of norma…
A non-persistent XSS (cross-site scripting) vulnerability exists in eWON Flexy and Cosy (all firmware versions prior to 14.1s0).
All version of Ewon Flexy and Cosy prior to 14.1 use wildcards such as (*) under which domains can request resources.