Vendors / Siemens Records 2488 All Threatist records
Exploited (KEV) 37 In CISA KEV
CVSS critical 333 CVSS 9.0–10.0
CVSS high 1406 CVSS 7.0–8.9
Exploited now Siemens records in CISA KEV
Components Products in the NVD configurations · select one to filter the records Priority MEDIUM 57
A vulnerability has been identified in SIMATIC HMI Comfort Panels (incl.
CVSS 3.1 CRITICAL 9.8· Network · No auth · No interaction · EPSS 0.05262 · Published 2021-02-09 · No fix listed CWE-306
Priority MEDIUM 54
A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl.
CVSS 3.1 CRITICAL 9.8· Network · No auth · No interaction · EPSS 0.02608 · Published 2021-05-12 · No fix listed CWE-788
Priority MEDIUM 45
The Telnet service of the SIMATIC HMI Comfort Panels system component in affected products does not require authentication, which may allow a remote attacker to gain access to the device if the service is enabled.
CVSS 3.1 CRITICAL 9.8· Network · No auth · No interaction · EPSS 0.01678 · Published 2021-06-28 · No fix listed CWE-306
Priority MEDIUM 45
SINAMICS medium voltage routable products are affected by a vulnerability in the Sm@rtServer component for remote access that could allow an unauthenticated attacker to cause a denial-of-service condition, and/or executi…
CVSS 3.1 CRITICAL 9.8· Network · No auth · No interaction · EPSS 0.01545 · Published 2021-06-15 · No fix listed CWE-20
Priority MEDIUM 44
A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl.
CVSS 3.1 HIGH 7.5· Network · No auth · No interaction · EPSS 0.02604 · Published 2021-05-12 · No fix listed CWE-400
Priority MEDIUM 43
Affected devices improperly handle large amounts of specially crafted UDP packets.
CVSS 3.1 HIGH 7.5· Network · No auth · No interaction · EPSS 0.02065 · Published 2019-10-10 · Fixed in V1.2.0, V4.3.0 +16 CWE-400
Priority MEDIUM 42
A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl.
CVSS 3.1 HIGH 7.5· Network · No auth · No interaction · EPSS 0.01826 · Published 2021-05-12 · No fix listed CWE-401
Priority MEDIUM 42
A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl.
CVSS 3.1 HIGH 7.5· Network · No auth · No interaction · EPSS 0.01826 · Published 2021-05-12 · No fix listed CWE-770
Priority MEDIUM 42
The webserver of the affected devices contains a vulnerability that may lead to a denial of service condition.
CVSS 3.1 HIGH 7.5· Network · No auth · No interaction · EPSS 0.01401 · Published 2019-04-17 · Fixed in V3.3, V3.2.16 +13 CWE-125
Priority LOW 36
An attacker with network access to an affected product may cause a denial of service condition by breaking the real-time synchronization (IRT) of the affected installation.
CVSS 3.1 HIGH 7.5· Network · No auth · No interaction · EPSS 0.01401 · Published 2019-10-10 · Fixed in V4.5.0, V5.2.1 +8 CWE-400
Priority LOW 34
Specially crafted PROFINET DCP broadcast packets could cause a denial of service condition of affected products on a local Ethernet segment (Layer 2).
CVSS 4.0 HIGH 7.1· Adjacent network · No auth · No interaction · EPSS 0.01149 · Published 2017-05-11 · Fixed in V01.01.01, V3.0 +35 CWE-400
Open these records in search → All records by CVSS severity
Critical333 High1406 Medium690 Low59 No CVSS0