TI-2011-02996 Aliases CVE-2011-3386GHSA-9w6r-m8w5-8xw6

Unspecified vulnerability in Medtronic Paradigm wireless insulin pump 512, 522, 712, and…

Priority LOW 22Published · Updated

Key facts

Attack vector
Network
Privileges required
None
User interaction
— Not recorded in CVSS 2.0
Attack complexity
High
Impact type
—
Confidentiality · integrity · availability
None · Partial · Partial
Fix status
No fix listed

Attack profile from CVSS 2.0 · NVD. Fix status from CNA.

Summary

Unspecified vulnerability in Medtronic Paradigm wireless insulin pump 512, 522, 712, and 722 allows remote attackers to modify the delivery of an insulin bolus dose and cause a denial of service (adverse human health effects) via unspecified vectors involving wireless communications and knowledge of the device's serial number, as demonstrated by Jerome Radcliffe at the Black Hat USA conference in August 2011. NOTE: the vendor has disputed the severity of this issue, saying "we believe the risk of deliberate, malicious, or unauthorized manipulation of medical devices is extremely low... we strongly believe it would be extremely difficult for a third-party to wirelessly tamper with your insulin pump... you would be able to detect tones on the insulin pump that weren't intentionally programmed and could intervene accordingly."

Why it matters now

EPSS 0.0145 73rd percentileScored 2026-11-07
Fix No fix listed No fixed version in the sources yet

SSVC decision points

Not available: CISA has not published SSVC decision points for this record.

Affected products

VendorProductAffected versionsFixed inStatusSource
——all versions—No fix listedCNA
  • — Vendor— Affected all versions Fixed in — No fix listed CNA

CPE configurations NVD · 4

CPEVersionsRoleVendor
cpe:2.3:h:medtronic:paradigm_wireless_insulin_pump:512:*:*:*:*:*:*:*512VulnerableMedtronic
cpe:2.3:h:medtronic:paradigm_wireless_insulin_pump:522:*:*:*:*:*:*:*522VulnerableMedtronic
cpe:2.3:h:medtronic:paradigm_wireless_insulin_pump:712:*:*:*:*:*:*:*712VulnerableMedtronic
cpe:2.3:h:medtronic:paradigm_wireless_insulin_pump:722:*:*:*:*:*:*:*722VulnerableMedtronic
  • cpe:2.3:h:medtronic:paradigm_wireless_insulin_pump:512:*:*:*:*:*:*:* Versions 512 Vulnerable ·Medtronic
  • cpe:2.3:h:medtronic:paradigm_wireless_insulin_pump:522:*:*:*:*:*:*:* Versions 522 Vulnerable ·Medtronic
  • cpe:2.3:h:medtronic:paradigm_wireless_insulin_pump:712:*:*:*:*:*:*:* Versions 712 Vulnerable ·Medtronic
  • cpe:2.3:h:medtronic:paradigm_wireless_insulin_pump:722:*:*:*:*:*:*:* Versions 722 Vulnerable ·Medtronic

Remediation

No fixed version listed by the sources yet.

Timeline

  1. 2026-10-02 Threatist record created from CVE-2011-3386
  2. 2026-10-03 Alias added: GHSA-9w6r-m8w5-8xw6

References

Sources