Priority HIGH 72
Deserialization of untrusted data in Microsoft Messaging Queuing Service in Medtronic's Paceart Optima versions 1.11 and earlier on Windows allows an unauthorized user to impact a healthcare delivery organization’s Pacea…
CVSS 3.1CRITICAL 9.8· Network · No auth · No interaction · EPSS 0.28495 · Published 2023-06-29 · No fix listed CWE-502
Priority MEDIUM 49
Medtronic MyCareLink Smart 25000 is vulnerable when an authenticated attacker runs a debug command, which can be sent to the patient reader and cause a heap overflow event within the MCL Smart Patient Reader software sta…
CVSS 3.1CRITICAL 9.8· Network · No auth · No interaction · EPSS 0.03931 · Published 2020-12-14 · No fix listed CWE-122
Priority MEDIUM 45
Medtronic MyCareLink Smart 25000 is vulnerable to a race condition in the MCL Smart Patient Reader software update system, which allows unsigned firmware to be uploaded and executed on the Patient Reader.
CVSS 3.1HIGH 8.8· Adjacent network · No auth · User interaction · EPSS 0.0384 · Published 2020-12-14 · No fix listed CWE-367
Priority MEDIUM 43
Medtronic CareLink Network allows an unauthenticated remote attacker to perform a brute force attack on an API endpoint that could be used to determine a valid password under certain circumstances.
CVSS 3.1CRITICAL 9.8· Network · No auth · No interaction · EPSS 0.00358 · Published 2025-12-04 · Fixed in December 4, 2025 CWE-307
Priority MEDIUM 42
The Conexus telemetry protocol utilized within Medtronic MyCareLink Monitor versions 24950 and 24952, CareLink Monitor version 2490C, CareLink 2090 Programmer, Amplia CRT-D, Claria CRT-D, Compia CRT-D, Concerto CRT-D, Co…
CVSS 3.1CRITICAL 9.3· Adjacent network · No auth · No interaction · EPSS 0.00895 · Published 2019-03-25 · No fix listed CWE-284
Priority LOW 39
Medtronic MyCareLink Smart 25000 contains an authentication protocol vulnerability where the method used to authenticate between the MCL Smart Patient Reader and the Medtronic MyCareLink Smart mobile app is vulnerable to…
CVSS 3.1HIGH 8.8· Adjacent network · No auth · No interaction · EPSS 0.00796 · Published 2020-12-14 · No fix listed CWE-287
Priority LOW 37
Medtronic Valleylab Exchange Client version 3.4 and below, Valleylab FT10 Energy Platform (VLFT10GEN) software version 4.0.0 and below, and Valleylab FX8 Energy Platform (VLFX8GEN) software version 1.1.0 and below use mu…
CVSS 3.1HIGH 7.5· Network · No auth · No interaction · EPSS 0.02011 · Published 2019-11-08 · No fix listed CWE-798
Priority LOW 34
Medtronic Valleylab Exchange Client version 3.4 and below, Valleylab FT10 Energy Platform (VLFT10GEN) software version 4.0.0 and below, and Valleylab FX8 Energy Platform (VLFX8GEN) software version 1.1.0 and below use th…
CVSS 3.1HIGH 7.8· Local · Low privileges · No interaction · EPSS 0.00268 · Published 2019-11-08 · No fix listed CWE-328
Priority LOW 34
Medtronic MiniMed Insulin Pumps are designed to communicate using a wireless RF with other devices, such as blood glucose meters, glucose sensor transmitters, and CareLink USB devices.
CVSS 3.1HIGH 7.1· Adjacent network · No auth · No interaction · EPSS 0.01234 · Published 2019-06-28 · No fix listed CWE-284
Priority LOW 34
Medtronic 2090 CareLink Programmer uses a virtual private network connection to securely download updates.
CVSS 3.1HIGH 7.1· Network · Low privileges · User interaction · EPSS 0.0132 · Published 2018-07-02 · No fix listed CWE-923
Priority LOW 32
Medtronic MyCareLink Patient Monitor has a built-in user account with an empty password, which allows an attacker with physical access to log in with no password and access modify system functionality.
CVSS 3.1MEDIUM 6.8· Physical · No auth · No interaction · EPSS 0.00305 · Published 2025-07-24 · Fixed in June 25, 2025 CWE-258
Priority LOW 31
Medtronic MyCareLink Patient Monitor uses per-product credentials that are stored in a recoverable format.
CVSS 3.1MEDIUM 6.8· Physical · No auth · No interaction · EPSS 0.00131 · Published 2026-05-07 · Fixed in February 25, 2026 CWE-313
Priority LOW 31
Medtronic MyCareLink Patient Monitor uses an unencrypted filesystem on internal storage, which allows an attacker with physical access to read and modify files.
CVSS 3.1MEDIUM 6.8· Physical · No auth · No interaction · EPSS 0.00215 · Published 2025-07-24 · Fixed in June 25, 2025 CWE-312
Priority LOW 31
Medtronic MyCareLink Patient Monitor has an internal serial interface, which allows an attacker with physical access to access a login prompt via a UART terminal.
CVSS 3.1MEDIUM 6.8· Physical · No auth · No interaction · EPSS 0.00157 · Published 2026-05-07 · Fixed in February 25, 2026 CWE-1263
Priority LOW 30
Medtronic CareLink Network allows an unauthenticated remote attacker to initiate a request for security questions to an API endpoint that could be used to determine a valid user account.
CVSS 3.1MEDIUM 5.3· Network · No auth · No interaction · EPSS 0.0032 · Published 2025-12-04 · Fixed in December 4, 2025 CWE-204
Priority LOW 30
Medtronic MyCareLink Patient Monitor has an internal service that deserializes data, which allows a local attacker to interact with the service by crafting a binary payload to crash the service or elevate privileges.
CVSS 3.1MEDIUM 6.5· Local · Low privileges · No interaction · EPSS 0.00194 · Published 2025-07-24 · Fixed in June 25, 2025 CWE-502
Priority LOW 30
Medtronic identified that the Pelvic Health clinician apps, which are installed on the Smart Programmer mobile device, have a password vulnerability that requires a security update to fix.
CVSS 3.1MEDIUM 6.8· Physical · No auth · No interaction · EPSS 0.00266 · Published 2023-03-01 · Fixed in A51200, A51300 CWE-620
Priority LOW 30
The 8840 Clinician Programmer executes the application program from the 8870 Application Card.
CVSS 3.1MEDIUM 6.3· Physical · No auth · User interaction · EPSS 0.00411 · Published 2018-07-13 · No fix listed CWE-693
Priority LOW 28
The Conexus telemetry protocol utilized within Medtronic MyCareLink Monitor versions 24950 and 24952, CareLink Monitor version 2490C, CareLink 2090 Programmer, Amplia CRT-D, Claria CRT-D, Compia CRT-D, Concerto CRT-D, Co…
CVSS 3.1MEDIUM 6.5· Adjacent network · No auth · No interaction · EPSS 0.00195 · Published 2019-03-26 · No fix listed CWE-319
Priority LOW 28
Medtronic 24950 MyCareLink Monitor and 24952 MyCareLink Monitor contains a hard-coded operating system password.
CVSS 3.1MEDIUM 6.4· Physical · No auth · No interaction · EPSS 0.00362 · Published 2018-07-02 · No fix listed CWE-259
Priority LOW 28
Medtronic 24950 MyCareLink Monitor and 24952 MyCareLink Monitor contains debug code meant to test the functionality of the monitor's communication interfaces, including the interface between the monitor and implantable c…
CVSS 3.1MEDIUM 6.2· Physical · Low privileges · No interaction · EPSS 0.00333 · Published 2018-07-02 · No fix listed CWE-749
Priority LOW 25
Medtronic MiniMed MMT devices when paired with a remote controller and having the “easy bolus” and “remote bolus” options enabled (non-default), are vulnerable to a capture-replay attack.
CVSS 3.1MEDIUM 5.3· Adjacent network · No auth · No interaction · EPSS 0.00712 · Published 2018-08-13 · No fix listed CWE-294
Priority LOW 24
Medtronic MyCareLink Patient Monitor uses per-product credentials that are stored in a recoverable format.
CVSS 3.1MEDIUM 5.2· Physical · No auth · No interaction · EPSS 0.00364 · Published 2018-08-10 · Fixed in February 25, 2026 CWE-313
Priority LOW 23
Communications between Medtronic MiniMed MMT pumps and wireless accessories are transmitted in cleartext.
CVSS 3.1MEDIUM 4.8· Adjacent network · No auth · User interaction · EPSS 0.00474 · Published 2018-08-13 · No fix listed CWE-319
Priority LOW 23
Medtronic 2090 CareLink Programmer’s software deployment network contains a directory traversal vulnerability that could allow an attacker to read files on the system.
CVSS 3.1MEDIUM 4.8· Adjacent network · Low privileges · No interaction · EPSS 0.0073 · Published 2018-05-04 · No fix listed CWE-23