Schneider Electric ProClima Command Injection
Priority MEDIUM 52CWE-77Published · Updated
Key facts
- Attack vector
- Network
- Privileges required
- None
- User interaction
- — Not recorded in CVSS 2.0
- Attack complexity
- Low
- Impact type
- Code execution
- Confidentiality · integrity · availability
- Complete · Complete · Complete
- Fix status
- No fix listed
Attack profile from CVSS 2.0 · CNA. Fix status from CNA. Impact type from CWE-77.
Summary
Buffer overflow in an ActiveX control in MDraw30.ocx in Schneider Electric ProClima before 6.1.7 allows remote attackers to execute arbitrary code via unspecified vectors, a different vulnerability than CVE-2014-8513 and CVE-2014-8514. NOTE: this may be clarified later based on details provided by researchers.
Why it matters now
EPSS 0.06287 93rd percentileScored 2026-11-07
Fix No fix listed No fixed version in the sources yet
SSVC decision points
Not available: CISA has not published SSVC decision points for this record.
Affected products
| Vendor | Product | Affected versions | Fixed in | Status | Source |
|---|---|---|---|---|---|
| Schneider Electric | ProClima | up to 6.0.1 | — | No fix listed | CNA |
- ProClima VendorSchneider Electric Affected up to 6.0.1 Fixed in — No fix listed CNA
CPE configurations NVD · 1
| CPE | Versions | Role | Vendor |
|---|---|---|---|
| cpe:2.3:a:schneider_electric:proclima:*:*:*:*:*:*:*:* | up to 6.0.1 | Vulnerable | Schneider Electric |
- cpe:2.3:a:schneider_electric:proclima:*:*:*:*:*:*:*:* Versions up to 6.0.1 Vulnerable ·Schneider Electric
Remediation
No fixed version listed by the sources yet.
Timeline
- 2026-10-02 Threatist record created from CVE-2014-9188
- 2026-10-03 Alias added: GHSA-9xw9-4ffg-hrqp
References
More Schneider Electric vulnerabilities
- TI-2018-05679 SQL injection in U.motion Builder software version 1.3.4 KEVCVSS 3.1CRITICAL 9.8
- TI-2021-05589 Hard-coded credentials in EVlink City , EVlink Parking , and EVlink Smart Wallbox CVSS 3.1CRITICAL 9.8
- TI-2022-15561 OS command injection in Schneider Electric SpaceLogic C-Bus Home Controller CVSS 3.1HIGH 8.8
- TI-2023-04970 Path traversal in Schneider Electric C-Bus Toolkit CVSS 3.1CRITICAL 9.8
- TI-2019-04862 Improper handling of exceptional conditions in Schneider Electric Modicon M580 CVSS 3.1HIGH 7.5
- TI-2018-05690 Improper handling of exceptional conditions in Modicon M580 Modicon M340 Modicon Quantum… CVSS 3.1HIGH 7.5
Sources
- CVE-2014-9188 · CVE Program
- CVE-2014-9188 · NVD
- FIRST EPSS
- GHSA-9xw9-4ffg-hrqp · GitHub Advisory Database · CC BY 4.0
This product uses the NVD API but is not endorsed or certified by the NVD. Sources and licences