Multiple buffer overflows in the F1BookView ActiveX control in F1 Bookview in Schneider…
Key facts
- Attack vector
- Network
- Privileges required
- None
- User interaction
- — Not recorded in CVSS 2.0
- Attack complexity
- Medium
- Impact type
- Code execution
- Confidentiality · integrity · availability
- Partial · Partial · Partial
- Fix status
- No fix listed
Attack profile from CVSS 2.0 · NVD. Fix status from CNA. Impact type from CWE-119 and the CVSS impact.
Summary
Multiple buffer overflows in the F1BookView ActiveX control in F1 Bookview in Schneider Electric ProClima before 6.2 allow remote attackers to execute arbitrary code via the (1) Attach, (2) DefinedName, (3) DefinedNameLocal, (4) ODBCPrepareEx, (5) ObjCreatePolygon, (6) SetTabbedTextEx, or (7) SetValidationRule method, a different vulnerability than CVE-2015-8561.
Why it matters now
SSVC decision points
Not available: CISA has not published SSVC decision points for this record.
Affected products
| Vendor | Product | Affected versions | Fixed in | Status | Source |
|---|---|---|---|---|---|
| — | — | all versions | — | No fix listed | CNA |
- — Vendor— Affected all versions Fixed in — No fix listed CNA
CPE configurations NVD · 1
| CPE | Versions | Role | Vendor |
|---|---|---|---|
| cpe:2.3:a:schneider-electric:proclima:*:*:*:*:*:*:*:* | up to 6.1 | Vulnerable | Schneider Electric |
- cpe:2.3:a:schneider-electric:proclima:*:*:*:*:*:*:*:* Versions up to 6.1 Vulnerable ·Schneider Electric
Remediation
No fixed version listed by the sources yet.
Timeline
- 2026-10-02 Threatist record created from CVE-2015-7918
- 2026-10-03 Alias added: GHSA-vxpx-99jp-v96v
References
Advisory 2
Other 7
- http://www.zerodayinitiative.com/advisories/ZDI-15-631
- http://www.zerodayinitiative.com/advisories/ZDI-15-625
- http://www.zerodayinitiative.com/advisories/ZDI-15-634
- http://www.zerodayinitiative.com/advisories/ZDI-15-632
- http://www.zerodayinitiative.com/advisories/ZDI-15-630
- http://www.zerodayinitiative.com/advisories/ZDI-15-633
- http://www.zerodayinitiative.com/advisories/ZDI-15-635
More Schneider Electric Proclima vulnerabilities
- TI-2019-04856 Code injection in Schneider Electric ProClima all versions prior to version 8.0.0 CVSS 3.1CRITICAL 9.8
- TI-2014-06987 Buffer overflow in an ActiveX control in Atx45.ocx in Schneider Electric ProClima before… CVSS 2.0HIGH 10.0
- TI-2019-04857 Memory corruption in Schneider Electric ProClima all versions prior to version 8.0.0 CVSS 3.1CRITICAL 9.8
- TI-2015-07044 The F1BookView ActiveX control in F1 Bookview in Schneider Electric ProClima before 6.2… CVSS 2.0MEDIUM 6.8
- TI-2019-04858 Uncontrolled search path in Schneider Electric ProClima all versions prior to version… CVSS 3.1HIGH 7.8
Sources
- CVE-2015-7918 · CVE Program
- CVE-2015-7918 · NVD
- FIRST EPSS
- GHSA-vxpx-99jp-v96v · GitHub Advisory Database · CC BY 4.0
This product uses the NVD API but is not endorsed or certified by the NVD. Sources and licences