The F1BookView ActiveX control in F1 Bookview in Schneider Electric ProClima before 6.2…
Key facts
- Attack vector
- Network
- Privileges required
- None
- User interaction
- — Not recorded in CVSS 2.0
- Attack complexity
- Medium
- Impact type
- Code execution
- Confidentiality · integrity · availability
- Partial · Partial · Partial
- Fix status
- No fix listed
Attack profile from CVSS 2.0 · NVD. Fix status from CNA. Impact type from CWE-119 and the CVSS impact.
Summary
The F1BookView ActiveX control in F1 Bookview in Schneider Electric ProClima before 6.2 allows remote attackers to execute arbitrary code or cause a denial of service (memory corruption) via a crafted integer value to the (1) AttachToSS, (2) CopyAll, (3) CopyRange, (4) CopyRangeEx, or (5) SwapTable method, a different vulnerability than CVE-2015-7918.
Why it matters now
SSVC decision points
Not available: CISA has not published SSVC decision points for this record.
Affected products
| Vendor | Product | Affected versions | Fixed in | Status | Source |
|---|---|---|---|---|---|
| — | — | all versions | — | No fix listed | CNA |
- — Vendor— Affected all versions Fixed in — No fix listed CNA
CPE configurations NVD · 1
| CPE | Versions | Role | Vendor |
|---|---|---|---|
| cpe:2.3:a:schneider-electric:proclima:*:*:*:*:*:*:*:* | up to 6.1 | Vulnerable | Schneider Electric |
- cpe:2.3:a:schneider-electric:proclima:*:*:*:*:*:*:*:* Versions up to 6.1 Vulnerable ·Schneider Electric
Remediation
No fixed version listed by the sources yet.
Timeline
- 2026-10-02 Threatist record created from CVE-2015-8561
- 2026-10-03 Alias added: GHSA-8jw8-h794-x973
- 2026-10-21 EPSS moved to the 90th–95th percentile
References
Advisory 2
More Schneider Electric Proclima vulnerabilities
- TI-2019-04856 Code injection in Schneider Electric ProClima all versions prior to version 8.0.0 CVSS 3.1CRITICAL 9.8
- TI-2014-06987 Buffer overflow in an ActiveX control in Atx45.ocx in Schneider Electric ProClima before… CVSS 2.0HIGH 10.0
- TI-2019-04857 Memory corruption in Schneider Electric ProClima all versions prior to version 8.0.0 CVSS 3.1CRITICAL 9.8
- TI-2015-06587 Multiple buffer overflows in the F1BookView ActiveX control in F1 Bookview in Schneider… CVSS 2.0MEDIUM 6.8
- TI-2019-04858 Uncontrolled search path in Schneider Electric ProClima all versions prior to version… CVSS 3.1HIGH 7.8
Sources
- CVE-2015-8561 · CVE Program
- CVE-2015-8561 · NVD
- FIRST EPSS
- GHSA-8jw8-h794-x973 · GitHub Advisory Database · CC BY 4.0
This product uses the NVD API but is not endorsed or certified by the NVD. Sources and licences