Improper handling of exceptional conditions in Philips IntelliVue MX40 Patient Worn…
Key facts
- Attack vector
- Adjacent network
- Privileges required
- None
- User interaction
- None
- Attack complexity
- Low
- Impact type
- —
- Confidentiality · integrity · availability
- None · None · High
- Fix status
- No fix listed
Attack profile from CVSS 3.0 · NVD. Fix status from CNA.
Summary
Under specific 802.11 network conditions, a partial re-association of the Philips IntelliVue MX40 Version B.06.18 WLAN monitor to the central monitoring station is possible. In this state, the central monitoring station can indicate the MX40 is not connected or associated to the central monitor, and thus should be operating in local monitoring mode (local audio-on, screen-on), but the MX40 WLAN itself can instead still be operating in telemetry mode (local audio-off, screen-off). If a patient experiences an alarm event and clinical staff expects the MX40 to provide local alarming when it is not available from the local device, a delay of treatment can occur. CVSS v3 base score: 6.5, CVSS vector string: AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H. Philips has released software update, Version B.06.18, to fix the improper cleanup on thrown exception vulnerability, and implement mitigations to reduce the risk associated with the improper handling of exceptional conditions vulnerability. The software update implements messaging and alarming on the MX40 and at the central monitoring station, when the MX40 disconnects from the access point.
Why it matters now
SSVC decision points
Not available: CISA has not published SSVC decision points for this record.
Affected products
| Vendor | Product | Affected versions | Fixed in | Status | Source |
|---|---|---|---|---|---|
| Philips | IntelliVue MX40 Patient Worn Monitor | IntelliVue MX40 Patient Worn Monitor (WLAN only), all versions prior to Version B.06.18 | — | No fix listed | CNA |
- IntelliVue MX40 Patient Worn Monitor VendorPhilips Affected IntelliVue MX40 Patient Worn Monitor (WLAN only), all versions prior to Version B.06.18 Fixed in — No fix listed CNA
Remediation
No fixed version listed by the sources yet.
Timeline
- 2026-10-02 Threatist record created from CVE-2017-9657
- 2026-10-03 Alias added: GHSA-32rc-pv7x-94gg
References
More Philips Intellivue Mx40 Firmware vulnerabilities
- TI-2017-07055 Improper handling of exceptional conditions in Philips IntelliVue MX40 Patient Worn… CVSS 3.0MEDIUM 6.5
Sources
- CVE-2017-9657 · CVE Program
- CVE-2017-9657 · NVD
- FIRST EPSS
- GHSA-32rc-pv7x-94gg · GitHub Advisory Database · CC BY 4.0
This product uses the NVD API but is not endorsed or certified by the NVD. Sources and licences