Read the docs
TI-2017-07054 Aliases CVE-2017-9657GHSA-32rc-pv7x-94gg

Improper handling of exceptional conditions in Philips IntelliVue MX40 Patient Worn…

Priority LOW 30CWE-460Published · Updated

Key facts

Attack vector
Adjacent network
Privileges required
None
User interaction
None
Attack complexity
Low
Impact type
—
Confidentiality · integrity · availability
None · None · High
Fix status
No fix listed

Attack profile from CVSS 3.0 · NVD. Fix status from CNA.

Summary

Under specific 802.11 network conditions, a partial re-association of the Philips IntelliVue MX40 Version B.06.18 WLAN monitor to the central monitoring station is possible. In this state, the central monitoring station can indicate the MX40 is not connected or associated to the central monitor, and thus should be operating in local monitoring mode (local audio-on, screen-on), but the MX40 WLAN itself can instead still be operating in telemetry mode (local audio-off, screen-off). If a patient experiences an alarm event and clinical staff expects the MX40 to provide local alarming when it is not available from the local device, a delay of treatment can occur. CVSS v3 base score: 6.5, CVSS vector string: AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H. Philips has released software update, Version B.06.18, to fix the improper cleanup on thrown exception vulnerability, and implement mitigations to reduce the risk associated with the improper handling of exceptional conditions vulnerability. The software update implements messaging and alarming on the MX40 and at the central monitoring station, when the MX40 disconnects from the access point.

Why it matters now

EPSS 0.00769 55th percentileScored 2026-11-07
Fix No fix listed No fixed version in the sources yet

SSVC decision points

Not available: CISA has not published SSVC decision points for this record.

Affected products

VendorProductAffected versionsFixed inStatusSource
PhilipsIntelliVue MX40 Patient Worn MonitorIntelliVue MX40 Patient Worn Monitor (WLAN only), all versions prior to Version B.06.18—No fix listedCNA
  • IntelliVue MX40 Patient Worn Monitor VendorPhilips Affected IntelliVue MX40 Patient Worn Monitor (WLAN only), all versions prior to Version B.06.18 Fixed in — No fix listed CNA

CPE configurations NVD · 2

CPEVersionsRoleVendor
cpe:2.3:o:philips:intellivue_mx40_firmware:*:*:*:*:*:*:*:*before b.06.18VulnerablePhilips
cpe:2.3:h:philips:intellivue_mx40:-:*:*:*:*:*:*:*not specified by NVDRunning onPhilips
  • cpe:2.3:o:philips:intellivue_mx40_firmware:*:*:*:*:*:*:*:* Versions before b.06.18 Vulnerable ·Philips
  • cpe:2.3:h:philips:intellivue_mx40:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Philips

Remediation

No fixed version listed by the sources yet.

Timeline

  1. 2026-10-02 Threatist record created from CVE-2017-9657
  2. 2026-10-03 Alias added: GHSA-32rc-pv7x-94gg

References

  • TI-2017-07055 Improper handling of exceptional conditions in Philips IntelliVue MX40 Patient Worn… CVSS 3.0MEDIUM 6.5

Sources