Improper handling of exceptional conditions in Philips IntelliVue MX40 Patient Worn…

Priority LOW 30CWE-755Published · Updated

Key facts

Attack vector
Adjacent network
Privileges required
None
User interaction
None
Attack complexity
Low
Impact type
—
Confidentiality · integrity · availability
None · None · High
Fix status
No fix listed

Attack profile from CVSS 3.0 · NVD. Fix status from CNA.

Summary

Certain 802.11 network management messages have been determined to invoke wireless access point blacklisting security defenses when not required, which can necessitate intervention by hospital staff to reset the device and reestablish a network connection to the Wi-Fi access point. During this state, the Philips IntelliVue MX40 Version B.06.18 can either connect to an alternative access point within signal range for association to a central monitoring station, or it can remain in local monitoring mode until the device is reset by hospital staff. CVSS v3 base score: 6.5, CVSS vector string: AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H. Philips has released software update, Version B.06.18, to fix the improper cleanup on thrown exception vulnerability, and implement mitigations to reduce the risk associated with the improper handling of exceptional conditions vulnerability. The software update implements messaging and alarming on the MX40 and at the central monitoring station, when the MX40 disconnects from the access point.

Why it matters now

EPSS 0.0081 57th percentileScored 2026-11-07
Fix No fix listed No fixed version in the sources yet

SSVC decision points

Not available: CISA has not published SSVC decision points for this record.

Affected products

VendorProductAffected versionsFixed inStatusSource
PhilipsIntelliVue MX40 Patient Worn MonitorIntelliVue MX40 Patient Worn Monitor (WLAN only), all versions prior to Version B.06.18—No fix listedCNA
  • IntelliVue MX40 Patient Worn Monitor VendorPhilips Affected IntelliVue MX40 Patient Worn Monitor (WLAN only), all versions prior to Version B.06.18 Fixed in — No fix listed CNA

CPE configurations NVD · 2

CPEVersionsRoleVendor
cpe:2.3:o:philips:intellivue_mx40_firmware:*:*:*:*:*:*:*:*before b.06.18VulnerablePhilips
cpe:2.3:h:philips:intellivue_mx40:-:*:*:*:*:*:*:*not specified by NVDRunning onPhilips
  • cpe:2.3:o:philips:intellivue_mx40_firmware:*:*:*:*:*:*:*:* Versions before b.06.18 Vulnerable ·Philips
  • cpe:2.3:h:philips:intellivue_mx40:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Philips

Remediation

No fixed version listed by the sources yet.