TI-2017-08572 Aliases CVE-2017-11578GHSA-hjx2-43ph-gqjc

It was discovered as a part of the research on IoT devices in the most recent firmware…

Priority LOW 30CWE-200Published · Updated

Key facts

Attack vector
Network
Privileges required
None
User interaction
None
Attack complexity
High
Impact type
Information disclosure
Confidentiality · integrity · availability
High · None · None
Fix status
No fix listed

Attack profile from CVSS 3.0 · NVD. Fix status from CNA. Impact type from CWE-200.

Summary

It was discovered as a part of the research on IoT devices in the most recent firmware for Blipcare device that the device allows to connect to web management interface on a non-SSL connection using plain text HTTP protocol. The user uses the web management interface of the device to provide the user's Wi-Fi credentials so that the device can connect to it and have Internet access. This device acts as a Wireless Blood pressure monitor and is used to measure blood pressure levels of a person. This allows an attacker who is connected to the Blipcare's device wireless network to easily sniff these values using a MITM attack.

Why it matters now

EPSS 0.02049 81st percentileScored 2026-11-07
Public exploit Yes 1 exploit referenceTagged by NVD
Fix No fix listed No fixed version in the sources yet

SSVC decision points

Not available: CISA has not published SSVC decision points for this record.

Affected products

VendorProductAffected versionsFixed inStatusSource
——all versions—No fix listedCNA
  • — Vendor— Affected all versions Fixed in — No fix listed CNA

CPE configurations NVD · 2

CPEVersionsRoleVendor
cpe:2.3:o:blipcare:wi-fi_blood_pressure_monitor_firmware:*:*:*:*:*:*:*:*up to bp700_10.1VulnerableBlipcare
cpe:2.3:h:blipcare:wi-fi_blood_pressure_monitor:-:*:*:*:*:*:*:*not specified by NVDRunning onBlipcare
  • cpe:2.3:o:blipcare:wi-fi_blood_pressure_monitor_firmware:*:*:*:*:*:*:*:* Versions up to bp700_10.1 Vulnerable ·Blipcare
  • cpe:2.3:h:blipcare:wi-fi_blood_pressure_monitor:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Blipcare

Remediation

No fixed version listed by the sources yet.

Timeline

  1. 2026-10-02 Threatist record created from CVE-2017-11578
  2. 2026-10-03 Alias added: GHSA-hjx2-43ph-gqjc

References

  • TI-2017-08573 In the most recent firmware for Blipcare, the device provides an open Wireless network… CVSS 3.0HIGH 7.1
  • TI-2017-08574 Blipcare Wifi blood pressure monitor BP700 10.1 devices allow memory corruption that… CVSS 3.0MEDIUM 6.5