Read the docs
TI-2017-08574 Aliases CVE-2017-11580GHSA-857g-5g59-pwmx

Blipcare Wifi blood pressure monitor BP700 10.1 devices allow memory corruption that…

Priority LOW 32CWE-399Published · Updated

Key facts

Attack vector
Adjacent network
Privileges required
None
User interaction
None
Attack complexity
Low
Impact type
Denial of service
Confidentiality · integrity · availability
None · None · High
Fix status
No fix listed

Attack profile from CVSS 3.0 · NVD. Fix status from CNA. Impact type from CWE-399 and the CVSS impact.

Summary

Blipcare Wifi blood pressure monitor BP700 10.1 devices allow memory corruption that results in Denial of Service. When connected to the "Blip" open wireless connection provided by the device, if a large string is sent as a part of the HTTP request in any part of the HTTP headers, the device could become completely unresponsive. Presumably this happens as the memory footprint provided to this device is very small. According to the specs from Rezolt, the Wi-Fi module only has 256k of memory. As a result, an incorrect string copy operation using either memcpy, strcpy, or any of their other variants could result in filling up the memory space allocated to the function executing and this would result in memory corruption. To test the theory, one can modify the demo application provided by the Cypress WICED SDK and introduce an incorrect "memcpy" operation and use the compiled application on the evaluation board provided by Cypress semiconductors with exactly the same Wi-Fi SOC. The results were identical where the device would completely stop responding to any of the ping or web requests.

Why it matters now

EPSS 0.01431 73rd percentileScored 2026-11-07
Public exploit Yes 1 exploit referenceTagged by NVD
Fix No fix listed No fixed version in the sources yet

SSVC decision points

Not available: CISA has not published SSVC decision points for this record.

Affected products

VendorProductAffected versionsFixed inStatusSource
——all versions—No fix listedCNA
  • — Vendor— Affected all versions Fixed in — No fix listed CNA

CPE configurations NVD · 2

CPEVersionsRoleVendor
cpe:2.3:o:blipcare:wi-fi_blood_pressure_monitor_firmware:*:*:*:*:*:*:*:*up to bp700_10.1VulnerableBlipcare
cpe:2.3:h:blipcare:wi-fi_blood_pressure_monitor:-:*:*:*:*:*:*:*not specified by NVDRunning onBlipcare
  • cpe:2.3:o:blipcare:wi-fi_blood_pressure_monitor_firmware:*:*:*:*:*:*:*:* Versions up to bp700_10.1 Vulnerable ·Blipcare
  • cpe:2.3:h:blipcare:wi-fi_blood_pressure_monitor:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Blipcare

Remediation

No fixed version listed by the sources yet.

Timeline

  1. 2026-10-02 Threatist record created from CVE-2017-11580
  2. 2026-10-03 Alias added: GHSA-857g-5g59-pwmx

References

  • TI-2017-08573 In the most recent firmware for Blipcare, the device provides an open Wireless network… CVSS 3.0HIGH 7.1
  • TI-2017-08572 It was discovered as a part of the research on IoT devices in the most recent firmware… CVSS 3.0MEDIUM 5.9

Sources