Read the docs
TI-2018-06410 Aliases CVE-2018-8868GHSA-c9h8-j583-w6wh

Medtronic MyCareLink Patient Monitor Exposed Dangerous Method or Function

Priority LOW 28CWE-749Published · Updated

Key facts

Attack vector
Physical
Privileges required
Low
User interaction
None
Attack complexity
High
Impact type
—
Confidentiality · integrity · availability
High · Low · Low
Fix status
No fix listed

Attack profile from CVSS 3.1 · CNA. Fix status from CNA.

Summary

Medtronic 24950 MyCareLink Monitor and 24952 MyCareLink Monitor contains debug code meant to test the functionality of the monitor's communication interfaces, including the interface between the monitor and implantable cardiac device. An attacker with physical access to the device can exploit other vulnerabilities to access this debug functionality. This debug functionality provides the ability to read and write arbitrary memory values to implantable cardiac devices via inductive or short range wireless protocols. An attacker with close physical proximity to a target implantable cardiac device can use this debug functionality.

Why it matters now

EPSS 0.00333 26th percentileScored 2026-11-07
Fix No fix listed No fixed version in the sources yet

SSVC decision points

Not available: CISA has not published SSVC decision points for this record.

Affected products

VendorProductAffected versionsFixed inStatusSource
Medtronic24950 MyCareLink MonitorAll versions—No fix listedCNA
Medtronic24952 MyCareLink MonitorAll versions—No fix listedCNA
  • 24950 MyCareLink Monitor VendorMedtronic Affected All versions Fixed in — No fix listed CNA
  • 24952 MyCareLink Monitor VendorMedtronic Affected All versions Fixed in — No fix listed CNA

CPE configurations NVD · 4

CPEVersionsRoleVendor
cpe:2.3:o:medtronic:24950_mycarelink_monitor_firmware:-:*:*:*:*:*:*:*not specified by NVDVulnerableMedtronic
cpe:2.3:h:medtronic:24950_mycarelink_monitor:-:*:*:*:*:*:*:*not specified by NVDRunning onMedtronic
cpe:2.3:o:medtronic:24952_mycarelink_monitor_firmware:-:*:*:*:*:*:*:*not specified by NVDVulnerableMedtronic
cpe:2.3:h:medtronic:24952_mycarelink_monitor:-:*:*:*:*:*:*:*not specified by NVDRunning onMedtronic
  • cpe:2.3:o:medtronic:24950_mycarelink_monitor_firmware:-:*:*:*:*:*:*:* Versions not specified by NVD Vulnerable ·Medtronic
  • cpe:2.3:h:medtronic:24950_mycarelink_monitor:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Medtronic
  • cpe:2.3:o:medtronic:24952_mycarelink_monitor_firmware:-:*:*:*:*:*:*:* Versions not specified by NVD Vulnerable ·Medtronic
  • cpe:2.3:h:medtronic:24952_mycarelink_monitor:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Medtronic

Remediation

No fixed version listed by the sources yet.

Timeline

  1. 2026-10-02 Threatist record created from CVE-2018-8868
  2. 2026-10-03 Alias added: GHSA-c9h8-j583-w6wh

References

  • TI-2018-06412 Medtronic MyCareLink Patient Monitor Use of Hard-coded Password CVSS 3.1MEDIUM 6.4