Medtronic MyCareLink 24950 Patient Monitor Insufficient Verification of Data Authenticity

Priority LOW 20CWE-345Published · Updated

Key facts

Attack vector
Adjacent network
Privileges required
Low
User interaction
None
Attack complexity
High
Impact type
Security bypass
Confidentiality · integrity · availability
Low · Low · None
Fix status
No fix listed

Attack profile from CVSS 3.1 · CNA. Fix status from CNA. Impact type from CWE-345.

Summary

Medtronic MyCareLink Patient Monitor’s update service does not sufficiently verify the authenticity of the data uploaded. An attacker who obtains per-product credentials from the monitor and paired implantable cardiac device information can potentially upload invalid data to the Medtronic CareLink network.

Why it matters now

EPSS 0.00361 30th percentileScored 2026-11-07
Fix No fix listed No fixed version in the sources yet

SSVC decision points

Not available: CISA has not published SSVC decision points for this record.

Affected products

VendorProductAffected versionsFixed inStatusSource
Medtronic24950 MyCareLink MonitorAll versions—No fix listedCNA
Medtronic24952 MyCareLink MonitorAll versions—No fix listedCNA
  • 24950 MyCareLink Monitor VendorMedtronic Affected All versions Fixed in — No fix listed CNA
  • 24952 MyCareLink Monitor VendorMedtronic Affected All versions Fixed in — No fix listed CNA

CPE configurations NVD · 4

CPEVersionsRoleVendor
cpe:2.3:o:medtronic:mycarelink_24952_patient_monitor_firmware:-:*:*:*:*:*:*:*not specified by NVDVulnerableMedtronic
cpe:2.3:h:medtronic:mycarelink_24952_patient_monitor:-:*:*:*:*:*:*:*not specified by NVDRunning onMedtronic
cpe:2.3:o:medtronic:mycarelink_24950_patient_monitor_firmware:-:*:*:*:*:*:*:*not specified by NVDVulnerableMedtronic
cpe:2.3:h:medtronic:mycarelink_24950_patient_monitor:-:*:*:*:*:*:*:*not specified by NVDRunning onMedtronic
  • cpe:2.3:o:medtronic:mycarelink_24952_patient_monitor_firmware:-:*:*:*:*:*:*:* Versions not specified by NVD Vulnerable ·Medtronic
  • cpe:2.3:h:medtronic:mycarelink_24952_patient_monitor:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Medtronic
  • cpe:2.3:o:medtronic:mycarelink_24950_patient_monitor_firmware:-:*:*:*:*:*:*:* Versions not specified by NVD Vulnerable ·Medtronic
  • cpe:2.3:h:medtronic:mycarelink_24950_patient_monitor:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Medtronic

Remediation

No fixed version listed by the sources yet.