Read the docs
TI-2018-11700 Aliases CVE-2018-16334GHSA-p98m-xpc7-793v

An issue was discovered on Tenda AC9 V15.03.05.19(6318)_CN and AC10 V15.03.06.23_CN…

Priority MEDIUM 44CWE-78Published · Updated

Key facts

Attack vector
Network
Privileges required
Low
User interaction
None
Attack complexity
Low
Impact type
Code execution
Confidentiality · integrity · availability
High · High · High
Fix status
No fix listed

Attack profile from CVSS 3.0 · NVD. Fix status from CNA. Impact type from CWE-78.

Summary

An issue was discovered on Tenda AC9 V15.03.05.19(6318)_CN and AC10 V15.03.06.23_CN devices. The mac parameter in a POST request is used directly in a doSystemCmd call, causing OS command injection.

Why it matters now

EPSS 0.0362 89th percentileScored 2026-11-07
Public exploit Yes 1 exploit referenceTagged by NVD
Fix No fix listed No fixed version in the sources yet

SSVC decision points

Not available: CISA has not published SSVC decision points for this record.

Affected products

VendorProductAffected versionsFixed inStatusSource
——all versions—No fix listedCNA
  • — Vendor— Affected all versions Fixed in — No fix listed CNA

CPE configurations NVD · 4

CPEVersionsRoleVendor
cpe:2.3:o:tendacn:ac10_firmware:*:*:*:*:*:*:*:*up to 15.03.06.23VulnerableTendacn
cpe:2.3:h:tendacn:ac10:-:*:*:*:*:*:*:*not specified by NVDRunning onTendacn
cpe:2.3:o:tendacn:ac9_firmware:15.03.05.19:*:*:*:*:*:*:*15.03.05.19VulnerableTendacn
cpe:2.3:h:tendacn:ac9:-:*:*:*:*:*:*:*not specified by NVDRunning onTendacn
  • cpe:2.3:o:tendacn:ac10_firmware:*:*:*:*:*:*:*:* Versions up to 15.03.06.23 Vulnerable ·Tendacn
  • cpe:2.3:h:tendacn:ac10:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Tendacn
  • cpe:2.3:o:tendacn:ac9_firmware:15.03.05.19:*:*:*:*:*:*:* Versions 15.03.05.19 Vulnerable ·Tendacn
  • cpe:2.3:h:tendacn:ac9:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Tendacn

Remediation

No fixed version listed by the sources yet.

Timeline

  1. 2026-10-02 Threatist record created from CVE-2018-16334
  2. 2026-10-03 Alias added: GHSA-p98m-xpc7-793v

References

  • TI-2023-18802 Tenda AC10 v15.03.06.26 was discovered to contain a command injection vulnerability via… CVSS 3.1CRITICAL 9.8
  • TI-2021-15902 Tenda AC10-1200 v15.03.06.23_EN was discovered to contain a buffer overflow via the urls… CVSS 3.1CRITICAL 9.8
  • TI-2018-11699 An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10… CVSS 3.0HIGH 7.5
  • TI-2022-09646 Tenda AC10-1200 v15.03.06.23_EN was discovered to contain a buffer overflow in the setSmartPowerManagement function. CVSS 3.1HIGH 7.5
  • TI-2021-16308 Tenda AC10-1200 v15.03.06.23_EN was discovered to contain a buffer overflow via the list… CVSS 3.1HIGH 7.5
  • TI-2018-10393 Tenda AC7 through V15.03.06.44_CN, AC9 through V15.03.05.19(6318)_CN, and AC10 through… CVSS 3.0HIGH 7.5

Sources